• 38KV Outdoor load break switch
38KV Outdoor load break switch
discuss personally
Model
RPS-38
Basic info
Brand ROCKWILL
Model NO. 38KV Outdoor load break switch
Rated voltage 38kV
Series RPS
Product Detail

Product Overview

The Rockwill RPS is a premium 38kV-class, SF6-insulated, pole-mounted load break switch designed for modern distribution automation systems. KEMA type-tested and built with 3mm stainless steel tank technology, it delivers maintenance-free operation in extreme environments (-45°C to +85°C) including coastal, industrial, and icy conditions. Available in manual, motorized, remote-controlled, and automatic sectionalizer configurations, the RPS features patented spiral spring mechanism and helium-leak detection to ensure ≤0.1% annual SF6 leakage.

Key Features:

  • Ultra-Robust Construction: 3mm stainless steel tank with minimal welds (arc-fault resistant)

  • Multi-Function Options: Manual/motorized/remote/automatic sectionalizer versions

  • Advanced Switching: Patented spiral spring mechanism (IEC62271-100 compliant speeds)

  • Clear Visual Indicators: Light-reflecting position markers visible at ground level

  • Bushing Choices: Porcelain/silicone rubber/cable termination options

  • Smart Monitoring: Operation counter & gas density gauge

Product Advantages:

  • All-Weather Reliability: Operates in -45°C to +85°C, 95% humidity, 2500m+ altitude

  • Fail-Safe Protection: Manual override prevents actuator failure blackouts (patented)

  • Corrosion Proof: Stainless steel tank + composite bushings resist salt/industrial pollution

  • Future-Ready: Field-upgradable from manual to motorized/remote operation

  • Enhanced Safety: Tank grounding prevents leakage currents; arc-resistant design

Application Scenarios:

  • Automated Distribution Networks: Remote-controlled feeder switching

  • Coastal/Industrial Areas: Corrosion-resistant power line control

  • Mountainous Regions: High-altitude (2500m+) grid management

  • Ice/Snow Zones: Reliable operation in -45°C conditions

  • Sectionalizing Systems: Fault isolation without upstream interruption

Environmental Compliance:

  • Temperature: -45°C to +85°C

  • Humidity: 95% monthly average

  • Altitude: 2500m+ (custom higher options)

  • Pollution: Resists salt/corrosive industrial atmospheres

Technical data

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
What to Pay Attention to When Selecting and Installing GIS Current Transformers?
What to Pay Attention to When Selecting and Installing GIS Current Transformers?
Hi everyone, I'm James, and I've been working with current transformers (CTs) for 10 years. Today, I’ll talk about what you need to watch out for when selecting and installing GIS current transformers.Part 1: Key Considerations During Selection1. Accuracy ClassProtection-grade CTs: Used for relay protection — focus on overload capacity and transient response.Metering-grade CTs: Used for billing purposes — require high accuracy, usually 0.2S or 0.5S class.2. Rated Primary Curren
James
07/07/2025
Selection of Primary Verification Circuit and Parameter Measurement for UHV GIS Current Transformers
Selection of Primary Verification Circuit and Parameter Measurement for UHV GIS Current Transformers
In UHV GIS, current transformers are key to electric energy metering. Their accuracy determines power trade settlements, so on - site error verification perJJG1021 - 2007is needed. On - site, use power supplies, voltage regulators, and current boosters. Due to encapsulation in GIS, build test circuits via exposed grounding knives, bushings, and return conductors; right circuits simplify wiring and boost accuracy.Challenges like large test current, long circuits, and high impedance exist, but rea
Oliver Watts
07/07/2025
What are the polarity test methods for GIS current transformers?
What are the polarity test methods for GIS current transformers?
I’m Oliver, an 8 - year current transformer testing pro. Today, let’s break down new and old polarity test methods for GIS current transformers—how they work and their pros/cons.1.Testing Methods1.1New MethodPre - test ops: Open FDS21/FDS22 fast disconnectors + DS23 disconnector. Close CB21 breaker, then ES21/ES22 grounding disconnectors. Disconnect ES21’s SF6 - shell ground.Wiring: Connect battery between ES21’s moving contact (negative grounded) + ground electrode
Oliver Watts
07/07/2025
Exploring the Design and Application of Photoelectric Current Transformers in GIS
Exploring the Design and Application of Photoelectric Current Transformers in GIS
1.Design and Application Example of Photoelectric Current Transformer in GISThis article takes a 126kV GIS project as a specific example to deeply explore the design ideas and practical application of photoelectric current transformers in the GIS system. Since this GIS project was officially put into operation, the power system has remained stable, with no major failures occurring, and the operation status is relatively ideal.1.1 Design and Application Ideas of Photoelectric Current TransformerI
Dyson
07/07/2025
Maintenance and Diagnostic Analysis of Current Transformers in GIS Equipment
Maintenance and Diagnostic Analysis of Current Transformers in GIS Equipment
I'm Oliver, with 8 years of experience in current transformer testing. These are all practical experiences, shared with you1 Maintenance of Current TransformersHaving been in the business of current transformer testing for 8 years, I know a thing or two about their maintenance! The maintenance of current transformers is divided into minor repairs, intermediate repairs, and major overhauls.Minor repairs mainly involve opening the cover (if necessary) and changing the oil, usually carried out once
Oliver Watts
07/07/2025
What are the possible causes of cracking failure in CT terminal blocks within GIS equipment?
What are the possible causes of cracking failure in CT terminal blocks within GIS equipment?
Gas - insulated switchgear (GIS) , often called “SF6 combined electrical apparatus”, is widely used in power systems for its high reliability, small footprint, low noise, and low loss. It encloses high - voltage devices like circuit breakers, fast grounding switches, current transformers, and busbars in a grounded metal shell filled withSF6gas. Each device sits in a separate gas chamber with different pressures. The CT terminal block divides gas chambers, connects components, and eas
Felix Spark
07/07/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!