• LZCT Current Transformer
LZCT Current Transformer
discuss personally
Model
LZCT-300/1
Basic info
Brand Wone Store
Model NO. LZCT Current Transformer
Rated frequency 50/60Hz
Power frequency withstand voltage 3kV
Rated current ratio 300/1
Series LZCT
Product Detail

Product Overview

Ring Main Unit C-GIS Bushing Type The secondary windings are full-enclosed in the flame retardant plastic shells,primary bushing or cable can pass through the inner hole, bottom has installation inserts for fixation. It is simple and shortcut, is suitable for measuring current, signal collection and protective relaying in the medium voltage power system of bushing or cable etc

Key Features

  • Fully Sealed Harsh Environment Structure:Vacuum-cast epoxy resin enclosure with IP68 rating (submersible up to 2m long-term), withstands -45°C~+85°C extremes. Passes 1000-hour salt spray test and UL94 V-0 flame retardant certification, ideal for coastal, mining, chemical zones. Maintenance-free design ensures 30+ years service life.
  • Wide-Range Multi-Tap Adaptability:Ratio range 50/5~2500/5A with 4 built-in taps (200/5A, 400/5A, 800/5A, 1600/5A), switched via pluggable links. 1:200 dynamic response maintains linearity from 0.5% rated current to 20kA short-circuit current.
  • Fast Transient Response & Low Power:Special magnetic circuit prevents core saturation during faults. Protection winding acts within ≤8ms (5P20 class). No-load loss ≤0.6VA, load loss ≤0.3VA—35% lower energy consumption than traditional models.
  • Smart Digital Interface Integration:Supports IEC 61850-9-2 (SV messages) and Modbus RTU. Built-in DSP enables waveform analysis and self-diagnosis, integrating with smart substation systems for remote monitoring and fault alert.

Technical Data

  • Rated secondary current:5A,1A
  • Power frequency withstand voltage: 3kV
  • Rated frequency: 50/60Hz
  • Installation site:Indoor
  • Technical standard:  IEC 60044-1

Specification

 

 

Know your supplier
Wone Store
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment/MV & LV CT PT/Switchgear parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
What to Pay Attention to When Selecting and Installing GIS Current Transformers?
What to Pay Attention to When Selecting and Installing GIS Current Transformers?
Hi everyone, I'm James, and I've been working with current transformers (CTs) for 10 years. Today, I’ll talk about what you need to watch out for when selecting and installing GIS current transformers.Part 1: Key Considerations During Selection1. Accuracy ClassProtection-grade CTs: Used for relay protection — focus on overload capacity and transient response.Metering-grade CTs: Used for billing purposes — require high accuracy, usually 0.2S or 0.5S class.2. Rated Primary Curren
James
07/07/2025
Selection of Primary Verification Circuit and Parameter Measurement for UHV GIS Current Transformers
Selection of Primary Verification Circuit and Parameter Measurement for UHV GIS Current Transformers
In UHV GIS, current transformers are key to electric energy metering. Their accuracy determines power trade settlements, so on - site error verification perJJG1021 - 2007is needed. On - site, use power supplies, voltage regulators, and current boosters. Due to encapsulation in GIS, build test circuits via exposed grounding knives, bushings, and return conductors; right circuits simplify wiring and boost accuracy.Challenges like large test current, long circuits, and high impedance exist, but rea
Oliver Watts
07/07/2025
What are the polarity test methods for GIS current transformers?
What are the polarity test methods for GIS current transformers?
I’m Oliver, an 8 - year current transformer testing pro. Today, let’s break down new and old polarity test methods for GIS current transformers—how they work and their pros/cons.1.Testing Methods1.1New MethodPre - test ops: Open FDS21/FDS22 fast disconnectors + DS23 disconnector. Close CB21 breaker, then ES21/ES22 grounding disconnectors. Disconnect ES21’s SF6 - shell ground.Wiring: Connect battery between ES21’s moving contact (negative grounded) + ground electrode
Oliver Watts
07/07/2025
Exploring the Design and Application of Photoelectric Current Transformers in GIS
Exploring the Design and Application of Photoelectric Current Transformers in GIS
1.Design and Application Example of Photoelectric Current Transformer in GISThis article takes a 126kV GIS project as a specific example to deeply explore the design ideas and practical application of photoelectric current transformers in the GIS system. Since this GIS project was officially put into operation, the power system has remained stable, with no major failures occurring, and the operation status is relatively ideal.1.1 Design and Application Ideas of Photoelectric Current TransformerI
Dyson
07/07/2025
Maintenance and Diagnostic Analysis of Current Transformers in GIS Equipment
Maintenance and Diagnostic Analysis of Current Transformers in GIS Equipment
I'm Oliver, with 8 years of experience in current transformer testing. These are all practical experiences, shared with you1 Maintenance of Current TransformersHaving been in the business of current transformer testing for 8 years, I know a thing or two about their maintenance! The maintenance of current transformers is divided into minor repairs, intermediate repairs, and major overhauls.Minor repairs mainly involve opening the cover (if necessary) and changing the oil, usually carried out once
Oliver Watts
07/07/2025
What are the possible causes of cracking failure in CT terminal blocks within GIS equipment?
What are the possible causes of cracking failure in CT terminal blocks within GIS equipment?
Gas - insulated switchgear (GIS) , often called “SF6 combined electrical apparatus”, is widely used in power systems for its high reliability, small footprint, low noise, and low loss. It encloses high - voltage devices like circuit breakers, fast grounding switches, current transformers, and busbars in a grounded metal shell filled withSF6gas. Each device sits in a separate gas chamber with different pressures. The CT terminal block divides gas chambers, connects components, and eas
Felix Spark
07/07/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!