• DS5A 40.5kV 72.5kV 126kV High voltage disconnect switch
DS5A 40.5kV 72.5kV 126kV High voltage disconnect switch
discuss personally
Model
DS5A-126/3150-50
DS5A-126/2500-50
DS5A-126/2000-50
DS5A-126/1250-50
DS5A-72.5/4000-40
DS5A-72.5/3150-40
DS5A-72.5/2500-40
DS5A-72.5/2000-40
DS5A-72.5/1250-40
DS5A-40.5/4000-20
DS5A-40.5/2500-20
DS5A-40.5/2000-20
DS5A-40.5/1250-20
DS5A-40.5/630-20
Basic info
Brand ROCKWILL
Model NO. DS5A 40.5kV 72.5kV 126kV High voltage disconnect switch
Rated voltage 126kV
Rated normal current 3150A
Rated frequency 50/60Hz
Rated peak value withstand current 125kA
Rated short-time withstand current 50kA
Series DS5A
Product Detail

Product introduction:

DS5A Switch Disconnector Is a kind of outdoor HV electricity transmission equipment’s al three-phase AC frequency of 50Hz/60Hz. It Is used for breaking or connecting HV lines under no loads so that the power lines can be changed and connected and the way the electricity runs is changed. In addition it can be used to exercise safe eleclrica.1 insulation for such HV electric apparatuses as bus and break.

This product has two posts with horizontal open breaks. It Is open able In the middle and accessible to the grounding switch on one side or two sides. 90°drive's isolating switch and grounding switches adopt cs11 manual operating mechanism to execute the tri-pole linkage;180°drive's isolating switch adopts CS11 manual operating mechanism or CS14g manual to execute the tri-pole linkage; the grounding Switch adopts CS11 manual actuator to realize the tri-pole linkage.

DS5A Switch Disconnector comprises three single poles and actuator. Each single pole is made of a base, post insulator and conductive part. Two rotating post insulators are installed at a base with two insulators forming an angle of 50° and arranged in V shape. The contact finger arms and contact head arms of the conductive knife switch are separately fixed onto the end of the Insulating post.

The actuator drives one side of the insulating post to revolve, and drives the other side of the insulating post to rotate reversely by 90° through the angular wheel or link lever, so that the knife switch will be in circumgyration to realize the opening and closing of the Switch Disconnector. A horizontal insulating open break will appear at the closing moment.

Main characteristic:

  • The conductive arm made of rectangular Al-alloy pipes is characterized by high strength, light, weigh, large radiation area and strong resistance against corruption.
  • DS5A adopts particular copper alloy to develop the self-contained contact. The contact point is tightened by the elastic force of the contact itself. The contact spring is eliminated to avoid possible drop of the contact in gripping force due to the spring's corrosion and shunting, possible heating and annealing, possible increment in contact resistance, and possible vicious cycle of the growing heat or the contact The contact is made of curved copper plate, forming a large connection area with the conductive arm. In the opening and dosing processes, there is a short trip of friction between the contact and the finger and the required operating force is small. The conductive part has been acknowledged by the Chinese competent authority as a new and practical patent.(Patent No.: 2103 2 20022.6)
  • The rotating parts of the Switch Disconnector are designed to be free of maintenance. The rotating base is designed into a closure structure which denies the access of moisture, dust and harmful gases so that the low-temperature lubricating cream within the bearing will not run off or harden. Within the bearing base are thrust ball bearing and radial ball bearing, both of which will share the gravity and horizontal component of the Switch Disconnector so that the operating torque will not increase after the long-term operation of the disconnect switch
  • The mechanical interlock between the primary switch and earthing switch is directly installed onto the principal axis of the primary switch and the revolution axis of the earthing switch. The interlock Is direct and reliable, eliminating the structurally complex gearbox. It also facilitates easy adjustment In the field erection and avoids the corrosion of the gear box.
  • Provide one-key sequential control "double confim1ation" function expansion

Main technical parameters:

GW5A-parameters.png

Order notice :

Product model, current, rated short-time withstand current and creepage distance must be specified at the goods-ordering time;

The Switch Disconnector offers several options of grounding (no, left, right, both left and right). Unless otherwise specified, the goods suppled will be considered as providing the option of right grounding;

The operating mechanism, voltage and the number of contacts for auxiliary switch;

Methods of installation: horizontal installation, installation by the iodination of 25",side installation. Unless otherwise specified, the horizontal installation will be taken as default;

Specify the type of power and voltage degree for the electromagnetic lock of the actuator.

 

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Impact Analysis of Voltage Transformer Installation on Line Side vs. Load Side of Power Inlet Circuit Breaker for (ATS)
Impact Analysis of Voltage Transformer Installation on Line Side vs. Load Side of Power Inlet Circuit Breaker for (ATS)
Automatic backup switching (ABTS) devices are core components ensuring the safe, reliable, and stable operation of factory power grids. Their startup logic strictly follows the dual criteria of "loss of voltage in the working power supply + no - current detection", effectively avoiding misjudgments caused by secondary disconnection of voltage transformers (VTs) or maloperations of ABTS due to secondary circuit faults of current transformers (CTs). The activation condition requires both "no volta
James
07/03/2025
What tests need to be done on voltage transformers?
What tests need to be done on voltage transformers?
Practical Experience Sharing from an Electrical Engineer in the FieldBy Oliver, 8 Years in the Electrical IndustryHi everyone, I'm Oliver, and I've been working in the electrical industry for 8 years.From early involvement in substation commissioning and equipment inspection, to now managing the maintenance and fault analysis of entire power systems, one of the most frequently encountered devices in my work has been the voltage transformer (VT / PT).Recently, a friend who's just starting out ask
Oliver Watts
07/03/2025
What are the development trends of voltage transformers?
What are the development trends of voltage transformers?
By Echo, 12 Years in the Electrical IndustryHi everyone, I'm Echo, and I've been working in the electrical industry for 12 years.From early involvement in commissioning and maintenance of distribution rooms to later participation in electrical system design and equipment selection for large-scale projects, I’ve witnessed how voltage transformers have evolved — from traditional analog devices to intelligent, digital components.The other day, a new colleague from a power company asked
Echo
07/02/2025
Design of Electromagnetic Compatibility Performance for Electronic Voltage Transformers
Design of Electromagnetic Compatibility Performance for Electronic Voltage Transformers
With the rapid development of power systems, electronic voltage transformers (EVTs), as key measurement devices in power systems, their performance stability and reliability are crucial for the safe and stable operation of power systems. The electromagnetic compatibility (EMC) performance, as one of the core indicators of EVTs, is directly related to the ability of the device to work normally in complex electromagnetic environments and whether it will cause electromagnetic interference to other
Dyson
07/02/2025
Case Analysis of Abnormal Secondary Circuits in Voltage Transformers
Case Analysis of Abnormal Secondary Circuits in Voltage Transformers
1. Fault SituationIn September 2023, as a front - line fault maintenance worker, I detected abnormal voltage on the 10kV Section I bus of a substation during monitoring duty and informed the operation and maintenance team. The monitoring system showed: U0 = 0 kV, Ua = 6.06 kV, Ub = 5.93 kV, Uc = 6.05 kV, Uab = 10.05 kV, Ubc = 5.94 kVMy team and I rushed to the site. We suspected the secondary air circuit breaker of the 10kV Section I bus voltage transformer was closed and found the U - phase fus
Felix Spark
07/02/2025
What are the causes of failure of ferromagnetic voltage transformers in new energy power stations?
What are the causes of failure of ferromagnetic voltage transformers in new energy power stations?
By Felix, 15 Years in the Electrical IndustryHi everyone, I'm Felix, and I've been working in the electrical industry for 15 years.From early involvement in traditional substation commissioning and maintenance to now managing electrical system operations for multiple photovoltaic and wind power projects, one of the most frequently encountered devices I deal with is the Electromagnetic Voltage Transformer (PT).The other day, a shift operator at a new energy plant asked me:“We have an electr
Felix Spark
07/02/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!