• DS4A  12kV 24kV 40.5kV 72.5kV 126kV 145kV 170kV High voltage disconnect switch
DS4A 12kV 24kV 40.5kV 72.5kV 126kV 145kV 170kV High voltage disconnect switch
discuss personally
Model
DS4A-170/2000-40
DS4A-145D/4000-50
DS4A-145D/3150-50
DS4A-145D/2500-40
DS4A-145D/2000-40
DS4A-145D/1600-40
DS4A-126D/4000-50
DS4A-126D/3150-50
DS4A-126D/2500-40
DS4A-126D/2000-40
DS4A-126D/1600-40
DS4A-72.5D/4000-50
DS4A-72.5D/3150-50
DS4A-72.5D/2500-40
DS4A-72.5D/2000-40
DS4A-72.5D/1600-40
DS4A-72.5D/1250-40
DS4A-40.5D/4000-50
DS4A-40.5D/3150-40
DS4A-40.5D/2500-40
DS4A-40.5D/2000-31.5
DS4A-40.5D/1250-31.5
DS4A-24D/2000-31.5
DS4A-24D/1250-31.5
DS4A-24D/630-31.5
DS4A-12D/2000-31.5
DS4A-12D/1250-31.5
DS4A-12D/630-31.5
Basic info
Brand ROCKWILL
Model NO. DS4A 12kV 24kV 40.5kV 72.5kV 126kV 145kV 170kV High voltage disconnect switch
Rated voltage 170kV
Rated normal current 2000A
Rated frequency 50/60Hz
Rated peak value withstand current 104kA
Rated short-time withstand current 40kA
Series DS4A
Product Detail

Product introduction:

DS4A-12/126/145/170D(W) Switch Disconnector are kinds of outdoor HV electricity transmission equipment’s at three-phase AC frequency of 50Hz/60Hz. It’s used for breaking or connecting HV lines under no loads so that the power lines can be changed and connected and the way the electricity runs is changed. in addition, it can be used to exercise safe electrical insulation for such HV electric apparatuses as bus and breaker.

This product has two insulators with horizontal center breaks. itis openable in the middle and accessible to the grounding switch on one side or two sides. The Switch Disconnector adopts CS14G or CS11 manual operating mechanism or CJ2 motor-based operating mechanism to realize the tri-pole linkage. The earthing switch adopts CS14G manual operating mechanism to realize tri-pole linkage.

In August 2005, this product passed the improvement technology review by State Grid Corporation (Jiangsu provincial branch).

DS4A Switch Disconnector comprises three single poles and operating mechanism. Each pole comprises a base, post insulators and conductive parts. Removable insulating posts are mounted at both sides of a long base, The conducive switch blade's contact arms are respectively fixed at the tops of the insulating posts. When the insulating post at one end of the actuator revolves to drive, with the help of the crossover lever, the reverse rotation of the insulating post at the other end by 90", the conductive switch blade will rotate on the horizontal surface to realize the starting and closing of the isolating switch. A horizontal insulating open break will appear at the opening moment.

Main characteristic:

  • The conductive arm made of rectangular Al-alloy pipes is characterized by high strength, light weight, large radiation area and corruption-resistance.
  • Adopt particular copper alloy to develop the self-contained contact, The contact point is tightened by the elastic force of the contact itself. The contact spring is eliminated to avoid possible drop of the contact in gripping force due to the spring's corrosion and shunting, heating and annealing, possible increment in contact resistance, and possible vicious cycle of the growing heat of the contact. The contact is made of curved copper plate, forming a large connection area with he conductive arm. In the opening and closing processes, there isa short trip of friction between the contact and the finger and he required operating force is small. The conductive part has been acknowledged by the Chinese competent authority as a new and practical patent.(Patent No.. Z103 2 20022.6)
  • The rotating parts of the disconnect switch are designed to be free of any maintenance. The rotating base is designed into a seal structure which denies the access of moisture, dust and harmful gases so that No.2 low-temperature lubricating cream within the bearing will not run off or harden, Within the bearing base are thrust ball bearing and radial ball bearing, both of which will share the gravity and horizontal component of the Switch Disconnector so that the operating torque will not increase after the long-term operation of the disconnect switch.
  • Provide one key sequential control "double confirmation" function expansion.

Main technical parameters:

GW4A-parameters.png

Order notice :

Product model, rated voltage, rated current, rated short-time withstand current and creepage distance must be specified at the goods ordering time;

The disconnect switch offers several options of grounding (no, left. right. both left and right). Unless otherwise specified, the goods supplied will be considered as proving the option of right grounding;

Notes:

  • The methods of Judging left and right grounding: hold out both arms and keep the arms In the same direction as the Switch Disconnector is open的The earthing switch will be considered as left grounding if on the left hand side, and right grounding if on the right hand side;
  • The actuator's model and name, voltage and the number of contacts for auxiliary switch;
  • Specify the type of power and voltage degree for the electromagnetic lock of the actuator.

 

 

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Development of an Outdoor Integrated Low - Voltage Current Transformer
Development of an Outdoor Integrated Low - Voltage Current Transformer
In power grid construction, line losses reflect planning, design, and operation management. They’re key for evaluating power systems. For refined low - voltage transformer area line loss management, accurate line loss counting is critical. So, solidifying basic data, ensuring data accuracy, and proper original data collection matter for analysis. We must also optimize factors affecting collection accuracy, make preventive measures, and boost refined line loss management.1 Current Status of
Dyson
07/05/2025
What might be the future development trends of outdoor current transformers?
What might be the future development trends of outdoor current transformers?
I'm Echo, a 12-Year Veteran in the CT Industry, Talking About What's Coming NextHi everyone, I'm Echo, and I've been working in the current transformer (CT) industry for 12 years.From learning wiring and equipment debugging with my mentor to now leading a team tackling complex on-site issues, I've witnessed many technological advancements and industry changes. Especially with outdoor current transformers, there have been significant developments, but also much room for improvement.A few days ago
Echo
07/05/2025
Ratio Trial Verification Method for Current Transformers
Ratio Trial Verification Method for Current Transformers
Fellow electric power calibration workers, you must have encountered this situation: The nameplate of an outdoor current transformer has been tormented by wind, sun, rain, and freezing, to the point where the transformation ratio is indistinguishable! Don't panic, we have a solution - use a current transformer calibrator and through the “transformation ratio trial calibration method”, we can figure out the actual transformation ratio and errors clearly. Here, taking the SHGQ - DC typ
Oliver Watts
07/05/2025
Why Does the Secondary Insulation of Outdoor Current Transformers Drop?
Why Does the Secondary Insulation of Outdoor Current Transformers Drop?
I'm Felix, a 15-Year Veteran in the CT Industry, Sharing What You Need to Watch Out ForHi everyone, I'm Felix, and I've been working with current transformers (CTs) for over 15 years. Today, let’s talk about why the secondary insulation of outdoor CTs sometimes drops, and what you can do to prevent it.Common Causes:1. Moisture Ingress — Poor Sealing is the Biggest Problem!Outdoor CTs are constantly exposed to wind and rain. If the sealing isn't tight enough, moisture can get inside a
Felix Spark
07/05/2025
What tests need to be conducted on current transformers?
What tests need to be conducted on current transformers?
By Oliver, 8 Years in the Electrical IndustryHi everyone, I'm Oliver, and I've been working in the electrical industry for 8 years.From early days doing substation equipment commissioning to now managing protection and metering configurations for entire distribution systems, one of the most frequently used devices in my work has been the Current Transformer (CT).Recently, a friend who's just starting out asked me:“How do you test current transformers? Is there a simple and effective way to
Oliver Watts
07/04/2025
What should be noted when choosing a current transformer for a 10kV station transformer circuit?
What should be noted when choosing a current transformer for a 10kV station transformer circuit?
Practical Experience Sharing from an Electrical Engineer in the FieldBy James, 10 Years in the Electrical IndustryHi everyone, I'm James, and I've been working in the electrical industry for 10 years.From early involvement in substation design and equipment selection, to later taking charge of relay protection and automation system commissioning for entire projects, one of the most frequently used devices in my work has been the current transformer (CT).Recently, a friend who's just starting out
James
07/04/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!