• GCS Type LV withdrawable switchgear
GCS Type LV withdrawable switchgear
discuss personally
Model
GCS-380
Basic info
Brand ROCKWILL
Model NO. GCS Type LV withdrawable switchgear
Rated frequency 50/60Hz
Rated insulation voltage 660(1000)V
Rated current Horizontal bus bar ≤4000A
Rated current Vertical bus bar 1000A
Rated voltage of main circuit AC 380(400)V
Rated voltage of auxiliary circuit AC 220V
Rated voltage of auxiliary circuit DC 110V
Series GCS
Product Detail

Description :

GCS LV withdrawable switchgear(hereinafter referred to as device) is developed according to the requirements from industry competent department, numerous electric users and design unit by original state mechanical department, united design group of power department. It conforms to national conditions and with higher technical performance index, and adapts the demands for power market development and able to compete with available imported products. The device passed the authentication jointly presided by two departments in July 1996 in Shanghai. It obtains the recognition and affirmation from manufacturing unit and power consumer construction. The device is applicable to the distribution system of power station, petroleum, chemical engineering, metallurgy, weaving and tall building industries etc. In the places with high automaticity and need computer to joint, such as large-scale power station and petrochemical industry system etc, it is the low voltage complete distribution device used in the generating and power supply system with three-phase AC50(60)Hz, rated working voltage 380V, rated current 4000A and below for distribution, motor central control and reactive power compensation. The device accords with standards IEC439- 1 and GB7251.1.

Main feature :

  • Main framework adopts 8MF bar steel. Both sides of bar steel is installed with 9.2mm mounting hole with modulus 20mm and 100mm. Inner installation is flexible and easy.

  • Two types of assembly form design for main framework, full assembly structure and partial (side frame and cross rail) welding structure for user selection. 

  • Each function compartment of device is separated mutually. The compartments are divided into function unit compartment, bus bar compartment and cable compartment. Each one has relative independent function. 

  • Horizontal bus bar adopts cabinet back level placed array pattern for enhancing the capacity of resisting electrodynamic force for bus bar. It is the basic measure for obtaining high short circuit strength capacity for main circuit. 

  • Cable compartment design makes cable outlet and inlet up and down convenient.

Main technical parameters:

GCS Type LV withdrawable switchgear.png

GCS Type LV withdrawable switchgear.png

Conditions for normal operating environment:

  • Ambient air temperature: -5℃ ~+40℃ and the average temperature should not exceed +35℃ in 24h.

  • Relative humidity should not exceed 50% at max temperature. Higher relative humidity is allowed at lower temperature. Ex. 90% at +20℃ . But in view of the temperature change, it is possible that moderate dews will produce casually. 

  • Altitude above sea level should not exceed 2000M.     

  • Installation gradient not exceed 5° .

  • Indoor without dust, corrosive gas and rain water attack.

Interior structure Diagram:

GCS Type LV withdrawable switchgear.png

GCS Type LV withdrawable switchgear.png

Q:What is withdrawable switchgear?

A:Withdrawable switchgear is a type of electrical switchgear that allows the circuit breaker and other components to be easily withdrawn from the main body of the switchgear for maintenance, repair or replacement without having to disconnect the entire power supply system. It enhances the flexibility and maintainability of the power system.

Q:What is LV switchgear?

A:LV switchgear refers to low-voltage switchgear, which is mainly used in power distribution systems to control, protect and isolate electrical circuits at low voltages, typically below 1000V. It includes components like circuit breakers, switches, fuses and relays, and is crucial for the safe and reliable operation of low-voltage electrical systems in various applications such as buildings, factories and data centers.


Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Documents
Restricted.
GCS Type LV withdrawale switchgear
Manual English
Consulting
Related Products
Related Knowledges
Development of an Outdoor Integrated Low - Voltage Current Transformer
Development of an Outdoor Integrated Low - Voltage Current Transformer
In power grid construction, line losses reflect planning, design, and operation management. They’re key for evaluating power systems. For refined low - voltage transformer area line loss management, accurate line loss counting is critical. So, solidifying basic data, ensuring data accuracy, and proper original data collection matter for analysis. We must also optimize factors affecting collection accuracy, make preventive measures, and boost refined line loss management.1 Current Status of
Dyson
07/05/2025
What might be the future development trends of outdoor current transformers?
What might be the future development trends of outdoor current transformers?
I'm Echo, a 12-Year Veteran in the CT Industry, Talking About What's Coming NextHi everyone, I'm Echo, and I've been working in the current transformer (CT) industry for 12 years.From learning wiring and equipment debugging with my mentor to now leading a team tackling complex on-site issues, I've witnessed many technological advancements and industry changes. Especially with outdoor current transformers, there have been significant developments, but also much room for improvement.A few days ago
Echo
07/05/2025
Ratio Trial Verification Method for Current Transformers
Ratio Trial Verification Method for Current Transformers
Fellow electric power calibration workers, you must have encountered this situation: The nameplate of an outdoor current transformer has been tormented by wind, sun, rain, and freezing, to the point where the transformation ratio is indistinguishable! Don't panic, we have a solution - use a current transformer calibrator and through the “transformation ratio trial calibration method”, we can figure out the actual transformation ratio and errors clearly. Here, taking the SHGQ - DC typ
Oliver Watts
07/05/2025
Why Does the Secondary Insulation of Outdoor Current Transformers Drop?
Why Does the Secondary Insulation of Outdoor Current Transformers Drop?
I'm Felix, a 15-Year Veteran in the CT Industry, Sharing What You Need to Watch Out ForHi everyone, I'm Felix, and I've been working with current transformers (CTs) for over 15 years. Today, let’s talk about why the secondary insulation of outdoor CTs sometimes drops, and what you can do to prevent it.Common Causes:1. Moisture Ingress — Poor Sealing is the Biggest Problem!Outdoor CTs are constantly exposed to wind and rain. If the sealing isn't tight enough, moisture can get inside a
Felix Spark
07/05/2025
What tests need to be conducted on current transformers?
What tests need to be conducted on current transformers?
By Oliver, 8 Years in the Electrical IndustryHi everyone, I'm Oliver, and I've been working in the electrical industry for 8 years.From early days doing substation equipment commissioning to now managing protection and metering configurations for entire distribution systems, one of the most frequently used devices in my work has been the Current Transformer (CT).Recently, a friend who's just starting out asked me:“How do you test current transformers? Is there a simple and effective way to
Oliver Watts
07/04/2025
What should be noted when choosing a current transformer for a 10kV station transformer circuit?
What should be noted when choosing a current transformer for a 10kV station transformer circuit?
Practical Experience Sharing from an Electrical Engineer in the FieldBy James, 10 Years in the Electrical IndustryHi everyone, I'm James, and I've been working in the electrical industry for 10 years.From early involvement in substation design and equipment selection, to later taking charge of relay protection and automation system commissioning for entire projects, one of the most frequently used devices in my work has been the current transformer (CT).Recently, a friend who's just starting out
James
07/04/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!