• Compact and Prefabricated Substation
Compact and Prefabricated Substation
discuss personally
Model
SHN-1000-2
Basic info
Brand ROCKWILL
Model NO. Compact Substation Prefabricated Substation
Rated voltage 35kV
Rated normal current 5000A
Series Compact Substation
Product Detail

Product overview

Compact substations, mini substations, and prefabricated substations are innovative alternatives to traditional indoor substations. These advanced units are engineered to fulfill diverse user requirements, including electric energy measurement, reactive power compensation, and customized high and low voltage configurations. They embody the future of small and medium-sized power distribution infrastructure.

Technical Specifications 

  • Electrical Parameters: Rated for AC frequencies of 50Hz/60HZ, with a maximum operating voltage of 35KV and a maximum operating current of 5000A. 

  • Wide Application: Ideal for industrial and mining enterprises, ports, public facilities, high-rise buildings, and residential communities. Our products have a strong global footprint, predominantly exported to Asia, Africa, and other regions. We also offer comprehensive OEM/ODM services to meet unique client needs.

  •  Standards Compliance: Adheres to international and national standards such as IEC60067 and GB 17467-2010, ensuring quality and reliability.

Product Advantages 

  • Cutting-edge Technology: Boasting a fully enclosed and insulated structure, these substations ensure safe and reliable operation. They are user-friendly, virtually maintenance-free, and offer cost-effective solutions with low equipment investment. 

  • Robust Shell Design: The casing features excellent durability, thermal insulation, and ventilation. It demonstrates stable performance in various environments, with corrosion resistance, dustproof, and waterproof properties, while maintaining an aesthetically pleasing appearance. Multiple shell materials are available, including steel plates, composite plates, stainless steel plates, and cement plates, with protection grades up to IP67. 

Functional Configuration 

Independent Compartments: 

  • Divided into three separate areas: high voltage room, low voltage room, and transformer room. 

  • High Voltage Room: Equipped with XGN15, HXGN17, or SF6 switchgear, ensuring efficient high-voltage management. Low Voltage Side: Utilizes panel or cabinet-mounted structures, enabling the creation of customized power supply schemes. It supports functions like power distribution, lighting control, reactive power compensation, and energy metering. The main switch can be a universal circuit breaker or an intelligent circuit breaker, providing flexible installation and easy operation. 

  • Transformer Options: Available with fully sealed oil-immersed transformers or dry type transformers to suit different application needs. 

  • Superior Busbar System: Supports three-phase four-wire or three-phase five-wire systems. Constructed from high-quality three-phase tinned copper busbars, it offers high mechanical strength and excellent heat dissipation capabilities.

Operating Conditions 

  • Temperature: Ambient air temperature ranges from -45 °C to 45 °C. 

  • Altitude: Suitable for altitudes up to 1000m; can be extended to 4000m with customized transformers and low-voltage components. 

  • Installation: Recommended for installation with a vertical inclination not exceeding 5°, in environments free from severe vibrations and impacts. 

  • Humidity: Operational in air humidity levels of up to 90% at +25℃.

  •  Environmental Requirements: Designed for use in areas without conductive dust, explosion hazards, or gases that could corrode metal and electrical components. Outdoor installations should be in locations where wind speeds do not exceed 35m/s. For conditions outside these norms, we offer custom solutions tailored to your specific requirements.

Ordering Guidelines 

When placing an order, please provide the following details:

 Main loop scheme diagram and secondary loop system diagram. Electrical schematic diagram of the auxiliary circuit and wiring terminal layout. Equipment layout drawing, combination drawing, and floor plan drawing. Model, specification, and quantity of main electrical components. Incoming and outgoing line methods and cable specifications. Preferred equipment shell material and color. Any other special requirements can be discussed and accommodated through direct negotiation with our manufacturing team. 

We warmly invite customers to visit our factory. With our OEM/ODM services, we can also customize the protection level according to your specific project demands.

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Analysis of the Safety and Reliability Assurance of Medium-Voltage Switchgear
Analysis of the Safety and Reliability Assurance of Medium-Voltage Switchgear
As a professional engaged in power system operations, I recognize that medium-voltage (MV) switchgear plays a pivotal role in power distribution, metering, and protection. Ensuring its operational safety and reliability is critical—any malfunction can severely disrupt the entire power system. To enhance reliability, we must prioritize design-level optimizations, enabling MV switchgear to fulfill its functions and safeguard grid stability.1. Definition of Medium-Voltage SwitchgearIn my prac
Felix Spark
06/10/2025
What should be noted when using indoor vacuum circuit breakers?
What should be noted when using indoor vacuum circuit breakers?
I. Overvoltage PreventionVacuum circuit breakers excel in interrupting performance, but high overvoltage may occur across inductors during the switching of inductive loads due to abrupt changes in loop current, which requires special attention. When switching small-capacity motors, starting currents are large, so measures like step-down starting should be adopted to limit the current.Transformers with different structures show distinct characteristics: oil-immersed transformers have high impulse
Echo
06/10/2025
The application of indoor high-voltage vacuum circuit breakers
The application of indoor high-voltage vacuum circuit breakers
In the first half of 2007, as project participants from the Electromechanical Equipment Company of Huaibei Mining Group, we carried out a technical transformation of the 10kV substation in the East Factory Area. Our primary task was to replace the original 10kV disconnector - oil - immersed circuit breaker units with ZN20 indoor high - voltage vacuum circuit breakers.Previously, the SN10 - 10 oil - immersed circuit breakers had been in operation for an extended period, leading to severe oil leak
Echo
06/09/2025
What are the common faults and corresponding solutions for indoor drawer-type high-voltage vacuum circuit breakers?
What are the common faults and corresponding solutions for indoor drawer-type high-voltage vacuum circuit breakers?
Inability to Push In or Withdraw the Draw-out CarriageThe main manifestation is difficulty in inserting the carriage, which may cause equipment damage and threaten production when severe. The causes and countermeasures are shown in Table 1.The circuit - breaker fails to close. It manifests as the closing core actuating but the circuit - breaker not closing successfully; or the closing core not actuating, which shows that the control circuit of the circuit - breaker is open - circuited or the mec
Felix Spark
06/09/2025
What are the common faults and handling methods of the operating mechanisms of 35kV and 10kV indoor vacuum circuit breakers?
What are the common faults and handling methods of the operating mechanisms of 35kV and 10kV indoor vacuum circuit breakers?
In power system operation and maintenance, we have found that 35kV and 10kV indoor vacuum circuit breakers, as core primary equipment of high-voltage switchgear, are widely used in main grid and user substations due to their high reliability and low maintenance workload. From daily inspections and live detection to routine maintenance, vacuum circuit breakers always remain our key focus, as their operational quality is directly related to the stability and reliability of the power system. This p
Felix Spark
06/09/2025
Analysis of the Impact of Vacuum Arc Chamber Inspection and Maintenance on Improving the Reliability of Vacuum Circuit Breakers
Analysis of the Impact of Vacuum Arc Chamber Inspection and Maintenance on Improving the Reliability of Vacuum Circuit Breakers
Vacuum circuit breakers are widely used in distribution networks. As core components of power supply equipment, their performance hinges on both vacuum interrupters’ capabilities and circuit breakers’ mechanical characteristics (contact opening distance, stroke, pressure, average closing/opening speed, closing bounce time, opening - closing asynchronism, operation times, and cumulative allowable wear of contacts). Both are critical for reliable operation. The vacuum interrupter is th
Oliver Watts
06/09/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放