• BI-DIRECTIONAL DC Fast Charger V2G/V2L/V2H
  • BI-DIRECTIONAL DC Fast Charger V2G/V2L/V2H
  • BI-DIRECTIONAL DC Fast Charger V2G/V2L/V2H
BI-DIRECTIONAL DC Fast Charger V2G/V2L/V2H
discuss personally
Model
WZ-V2G-40KW-1T
WZ-V2G-40KW-1J
WZ-V2G-40KW-1U
WZ-V2G-40KW-1E
WZ-V2G-40KW-1C
WZ-V2G-30KW-1C
WZ-V2G-30KW-1E
WZ-V2G-30KW-1U
WZ-V2G-30KW-1J
WZ-V2G-30KW-1T
WZ-V2G-15KW-1T
WZ-V2G-22KW-1T
WZ-V2G-22KW-1C
WZ-V2G-22KW-1E
WZ-V2G-22KW-1U
WZ-V2G-22KW-1J
WZ-V2G-15KW-1J
WZ-V2G-15KW-1E
WZ-V2G-15KW-1U
Basic info
Brand RW Energy
Model NO. BI-DIRECTIONAL DC Fast Charger
Rated Output Rating 40KW
Output Voltage DC 200-1000V
Power Conversion Efficiency ≥95%
Connector Options Tesla
Cable Length 5m
Input Voltage 380V
Series DC EV Chargers
Product Detail

BI-DIRECTIONAL DC Fast Charger

This BI-DIRECTIONAL DC Fast Charger supports three major modes: V2G (Vehicle-to-Grid), V2L (Vehicle-to-Load), and V2H (Vehicle-to-Home), redefining electrical energy interaction. With V2G technology, vehicles can charge during low-power consumption periods and feed power back to the grid during peak hours, aiding in peak shaving and valley filling while generating revenue. In V2L mode, the charger transforms into a high-power mobile power source, providing stable electricity for camping equipment, outdoor machinery, emergency rescue gear, and other loads. The V2H function enables electric vehicles to serve as home backup power, ensuring household appliances operate during power outages or optimizing home electricity costs. Supporting a maximum charging power of 350kW and discharging power of 100kW, it is equipped with an intelligent power regulation and bidirectional energy management system to ensure efficient, stable, and safe bidirectional power transmission, making it a core device for the future smart energy ecosystem.

Features:

  •  Connectors - GBT/CCS1/CCS2/CHAdeMO/Tesla.

  • Support V2G/V2L/V2H.

  • Configurable output power settings.

  • RFID Reader.

  • Optional Credit Card Reader.

  •  Station-level monitoring platform.

  • FRU Onboard Diagnostics.

  •  Easy to Service.

Specifications:

image.png

image.png

image.png

image.png

Bi-directional function:

  • V2G (Vehicle to Grid): Vehicle to grid. That is, electric vehicles can not only obtain electrical energy from the grid for charging, but also feed back the electrical energy in the vehicle battery to the grid under certain circumstances to realize reverse transmission of electrical energy. This helps to peak-shave and valley-fill the grid, improve the stability and efficiency of the grid. At the same time, vehicle owners may also obtain certain economic benefits.

  • V2L (Vehicle to Load): Vehicle to load. It can use electric vehicles as a mobile power source to supply power to other external load devices. For example, when camping outdoors, it can supply power to electric ovens, stereos and other devices, expanding the usage scenarios of electric vehicles.

  • V2H (Vehicle to Home): Vehicle to home. It enables electric vehicles to be connected to the home's power system and provide emergency power for the home in case of power outages or charge at low electricity prices and supply power to the home at peak times to save home electricity costs.

what is V2G technology? In short, it is based on two-way charging piles, combined with energy management systems and cloud platform intelligent scheduling technology, and connected to the power grid dispatching system to realize the intelligent two-way transmission of electrical energy between the power grid and vehicles, meeting the purposes of vehicle transportation, new energy access, and stable control of the power grid.

Know your supplier
RW Energy
Zhejiang Rockwell Energy Technology Co., Ltd. is an international enterprise specializing in the research, development and manufacturing of recloser controllers, power quality management, power monitoring systems and other high-end power equipment. In today's critical period of global energy transition and power system upgrading, the company has gathered a group of top talents in the fields of power engineering, automation control, software development, etc., who carry the enthusiasm and persistence for the power business, and are committed to overcoming the complex problems in the power system, and promoting the intelligent development of the power industry with innovative technology. Mission: To make global electricity smarter, more reliable and more efficient with innovative technology. Vision: To be the leader in global power intelligence.
Main Categories
High voltage/New energy/Tester
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$100000000
Professional Experience
12 years
Workplace
30000m²
占位
占位
Related Products
Related Knowledges
Development of an Outdoor Integrated Low - Voltage Current Transformer
Development of an Outdoor Integrated Low - Voltage Current Transformer
In power grid construction, line losses reflect planning, design, and operation management. They’re key for evaluating power systems. For refined low - voltage transformer area line loss management, accurate line loss counting is critical. So, solidifying basic data, ensuring data accuracy, and proper original data collection matter for analysis. We must also optimize factors affecting collection accuracy, make preventive measures, and boost refined line loss management.1 Current Status of
Dyson
07/05/2025
What might be the future development trends of outdoor current transformers?
What might be the future development trends of outdoor current transformers?
I'm Echo, a 12-Year Veteran in the CT Industry, Talking About What's Coming NextHi everyone, I'm Echo, and I've been working in the current transformer (CT) industry for 12 years.From learning wiring and equipment debugging with my mentor to now leading a team tackling complex on-site issues, I've witnessed many technological advancements and industry changes. Especially with outdoor current transformers, there have been significant developments, but also much room for improvement.A few days ago
Echo
07/05/2025
Ratio Trial Verification Method for Current Transformers
Ratio Trial Verification Method for Current Transformers
Fellow electric power calibration workers, you must have encountered this situation: The nameplate of an outdoor current transformer has been tormented by wind, sun, rain, and freezing, to the point where the transformation ratio is indistinguishable! Don't panic, we have a solution - use a current transformer calibrator and through the “transformation ratio trial calibration method”, we can figure out the actual transformation ratio and errors clearly. Here, taking the SHGQ - DC typ
Oliver Watts
07/05/2025
Why Does the Secondary Insulation of Outdoor Current Transformers Drop?
Why Does the Secondary Insulation of Outdoor Current Transformers Drop?
I'm Felix, a 15-Year Veteran in the CT Industry, Sharing What You Need to Watch Out ForHi everyone, I'm Felix, and I've been working with current transformers (CTs) for over 15 years. Today, let’s talk about why the secondary insulation of outdoor CTs sometimes drops, and what you can do to prevent it.Common Causes:1. Moisture Ingress — Poor Sealing is the Biggest Problem!Outdoor CTs are constantly exposed to wind and rain. If the sealing isn't tight enough, moisture can get inside a
Felix Spark
07/05/2025
What tests need to be conducted on current transformers?
What tests need to be conducted on current transformers?
By Oliver, 8 Years in the Electrical IndustryHi everyone, I'm Oliver, and I've been working in the electrical industry for 8 years.From early days doing substation equipment commissioning to now managing protection and metering configurations for entire distribution systems, one of the most frequently used devices in my work has been the Current Transformer (CT).Recently, a friend who's just starting out asked me:“How do you test current transformers? Is there a simple and effective way to
Oliver Watts
07/04/2025
What should be noted when choosing a current transformer for a 10kV station transformer circuit?
What should be noted when choosing a current transformer for a 10kV station transformer circuit?
Practical Experience Sharing from an Electrical Engineer in the FieldBy James, 10 Years in the Electrical IndustryHi everyone, I'm James, and I've been working in the electrical industry for 10 years.From early involvement in substation design and equipment selection, to later taking charge of relay protection and automation system commissioning for entire projects, one of the most frequently used devices in my work has been the current transformer (CT).Recently, a friend who's just starting out
James
07/04/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!