• Advanced Recloser Controller
  • Advanced Recloser Controller
Advanced Recloser Controller
discuss personally
Model
RWK-651HBV
Basic info
Brand RW Energy
Model NO. Advanced Recloser Controller
Rated voltage 230V ±20%
Rated frequency 50/60Hz
Electric energy consumption ≤5W
Version V2.3.0-FA
Series RWK-65
Product Detail

Description

RWK-65 is an intelligent medium Voltage controller used in overhead line grid monitoring for the purpose of overhead line protection. It can be equipped with CW(VB) type vacuum circuit breaker to achieve automatic monitoring, fault analysis and store event records.

This unit offers safe line switching of faults on the power grid and provides automatic power recovery. RWK-65 series is suitable for up to 35kV outdoor switchgear include: vacuum circuit breakers, oil circuit breakers and gas circuit breakers. RWK-65 intelligent controller is equipped with line protection, control, measurement and monitoring of Voltage and current signals integrated automation and control devices outdoors.

RWK is a automatic management unit for single way/multi ways/ring network/two power sourcing, provided with all Voltage and current signals and all functions. RWK-65 column switch intelligent controller supports: Wireless (GSM/GPRS/CDMA), Ethernet mode, WIFI, optical fiber, power line carrier, RS232/485, RJ45 and other forms of communication, and can access other station premises equipment (such as TTU, FTU, DTU, etc.).

Main function introduction

1. Local Feeder Automation:

1) Adaptive comprehensive type, Adaptive comprehensive feeder automation is achieved through the "voltage loss opening, power delay closing" method, combined with short circuit/ground fault detection technology and fault path priority processing control strategy, in conjunction with the secondary closing of substation outgoing switches, to achieve fault localization and isolation adaptation of multi branch and multi connection distribution network structures.   The first closing isolates the fault section, and the second closing restores power supply to no fault sections.

2) Voltage time type, The "voltage time type" feeder automation is achieved by combining the working characteristics of the switch "no voltage opening, power delay closing" with the secondary closing of the substation outgoing switch.  The first closing isolates the fault section, and the secondary closing restores the power supply to the no fault section.  

3) Voltage current time type, The voltage current time type adds discrimination for fault current and grounding current on the basis of the voltage time type, following the basic logic of closing within the X time limit of power on, detecting residual voltage lockout within the Y time limit, losing voltage within the Y time limit after closing, and detecting fault current lockout and opening.   At the same time, it has the logic of locking and opening without detecting fault current within the Y time limit after closing, thereby accelerating the process of fault isolation. If the switch adopts a spring operated mechanism, it can be quickly isolated from instantaneous faults by adding a power loss delayed opening (in conjunction with the fast reclosing time of the substation outgoing switch).

2. Protection relay functions:

1) 79 Auto Reclose (Reclose) ,

2) 50P Instantaneous/Definite-Time Overcurrent (P.OC) ,

3) 51P Phase Time-Overcurrent(P.Fast curve/P.Delay curve),

4) 50/67P Directional Phase Overcurrent (P.OC-Direction mode (2-Forward /3-Reverse)),

5) 51/67P Directional Phase Time-Overcurrent (P.Fast curve/P.Delay curve-Direction mode (2-Forward/3-Reverse)),

6) 50G/N Ground Instantaneous/Definite-Time Overcurrent (G.OC),

7) 51G/N Ground Time-Overcurrent (G.Fast curve/G.Delay curve),

8) 50/67G/N Directional Ground Overcurrent (G.OC- Direction mode (2-Forward/3-Reverse)) ,

9) 51/67G/P Directional Ground Time-Overcurrent (P.Fast curve/P.Delay curve-Direction  mode (2-Forward/3-Reverse)),

10) 50SEF Sensitive Earth Fault (SEF), 

11) 50/67G/N Directional Sensitive Earth Fault (SEF-Direction mode (2-Forward/ 3-Reverse)) ,

12) 59/27TN Earth Fault Protection With 3RD Harmonics (SEF-Harmonic inhibit enabled) ,

13)  51C   Cold Load,

14) TRSOTF Switch-Onto-Fault (SOTF) ,

15) 81 Frequency protection ,

16) 46 Negative- Sequence Overcurrent (Nega.Seq.OC),

17) 27 Under Voltage (L.Under volt),

18) 59 Over Voltage (L.Over volt),

19) 59N Zero-Sequence Over Voltage (N.Over volt),

20) 25N Synchronism-Check,

21) 25/79 Synchronism-Check/Auto Reclose,

22) 60 Voltage unbalance,

23) 32 Power direction, 

24) Inrush,

25) Loss of phase, 

26) Live load block, 

27) High gas, 

28) High temperature,

29) hotline protection.

3. Supervision functions:

1) 74T/CCS Trip & Close Circuit Supervision,

2) 60VTS.   VT Supervision.

4. Control functions: 

1) 86    Lockout, 

2) circuit-breaker control.

5. Monitoring Functions: 

1) Primary/Secondary Phases and Earth Currents,

2) Phases Current with 2nd Harmonics and Earth Current With 3RD Harmonics, 

3) Direction, Primary/Secondary Line and Phase Voltages,

4) Apparent Power and Power Factor,

5) Real and Reactive Power, 

6) Energy and History Energy,

7) Max Demand and Month Max Demand, 

8) Positive Phase Sequence Voltage,

9) Negative Phase Sequence Voltage & Current,

10) Zero Phase Sequence Voltage,

11) Frequency, Binary Input/Output status,

12) Trip circuit healthy/failure,

13) Time and date,

14) Trip, alarm,

15) signal records, Counters,

16) Wear, Outage.

6. Communication functions:

a. Communication interface: RS485X1,RJ45X1

b. Communication protocol: IEC60870-5-101; IEC60870-5-104; DNP3.0;  Modbus-RTU

c. PC software: RWK381HB-V2.1.3,The address of the information body can be edited and queried by PC software,

d. SCADA system: SCADA systems that support the four protocols shown in "b.”.

7. Data Storage functions:

1) Event Records,

2) Fault Records,

3) Measurands.

8. remote signaling remote measuring, remote controlling function can be customized address.

Technology parameters

paramete.png

Device structure

RWK-65尺寸图-Model.png

控制器的应用方案.png


About customization

The following optional functions are available: Power supply rated at 110V/60Hz,Two three-phase voltage sensors, cabinet heating defrosting device, battery upgrade to lithium battery or other storage equipment, GPRS communication module,1~2 signal indicators,1~4 protection pressure plates, the second voltage transformer, custom aviation socket signal definition.

For detailed customization, please contact the salesman.

Q: What is a recloser?

A: The reclosing device is a device that can automatically detect the fault current, and automatically cut off the circuit when the fault occurs, and then perform multiple reclosing operations.

Q: What is the function of the recloser?

A: It is mainly used in the distribution network. When there is a temporary fault in the line (such as a branch touching the line for a short time), the reclosing device restores power supply by reclosing operation, which greatly reduces the outage time and scope and improves power supply reliability.

Q: How does the recloser determine the type of failure?

A: It monitors characteristics such as the magnitude and duration of fault currents. If the fault is permanent, after a preset number of reclosing, the reclosing device will be locked to avoid further damage to the device.

Q: What are the application scenarios of reclosers?

A: It is widely used in the urban distribution network and rural power supply network, which can effectively cope with various possible line failures and ensure the stable supply of power.

Know your supplier
RW Energy
Zhejiang Rockwell Energy Technology Co., Ltd. is an international enterprise specializing in the research, development and manufacturing of recloser controllers, power quality management, power monitoring systems and other high-end power equipment. In today's critical period of global energy transition and power system upgrading, the company has gathered a group of top talents in the fields of power engineering, automation control, software development, etc., who carry the enthusiasm and persistence for the power business, and are committed to overcoming the complex problems in the power system, and promoting the intelligent development of the power industry with innovative technology. Mission: To make global electricity smarter, more reliable and more efficient with innovative technology. Vision: To be the leader in global power intelligence.
Main Categories
High voltage/New energy/Tester
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$100000000
Professional Experience
12 years
Workplace
30000m²
占位
占位
Documents
Public.
RWK-65 Automatic Recloser controller
Manual English
Consulting
Related Products
Related Knowledges
Modular Intelligent Substation - Prefabricated Secondary Switchgear Integration Assembly
Modular Intelligent Substation - Prefabricated Secondary Switchgear Integration Assembly
With the development of the national economy and society, the requirements for the quality and craftsmanship of power grid projects have become increasingly stringent. The need to improve the construction progress and quality of substations has created opportunities for the promotion of prefabricated cabin - type intelligent substations. The traditional on - site wiring and commissioning of secondary substation equipment involve a large amount of work. Moreover, on - site construction has to wai
Echo
06/13/2025
Application of Pre-integrated Prefabricated Substations in Renewable Energy Sector
Application of Pre-integrated Prefabricated Substations in Renewable Energy Sector
Against the backdrop of profound changes in the global energy landscape and the booming development of the new energy industry, the construction mode of traditional substations struggles to meet the rapid deployment needs of new energy projects. The modular intelligent prefabricated cabin substation, leveraging its innovative advantages, has become a key direction for optimizing the new energy power system. In - depth exploration of its technical principles, industry adaptability, and applicatio
Echo
06/13/2025
Research on Reliability Enhancement Scheme Implementation for Modular Intelligent Prefabricated Substations
Research on Reliability Enhancement Scheme Implementation for Modular Intelligent Prefabricated Substations
1 Implementation Strategies for the Scheme1.1 Deepen Survey and ResearchBefore constructing prefabricated cabin - type substations, it is necessary to conduct detailed surveys of local working conditions, clarify the construction scale and objectives, evaluate existing power facilities, plan projects, make up for infrastructure shortcomings, and adjust the construction rhythm. Meanwhile, control costs to avoid project suspension.1.2 Strengthen Structural ConstructionDuring promotion, multi - dim
Echo
06/13/2025
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
The secondary equipment area of conventional substations uses reinforced concrete or prefabricated steel structures, facing issues like long construction cycles, unreasonable functional zone design, strict environmental assessments, dust, noise, and disturbances. Primary and secondary equipment can only be installed after civil works and decoration, lowering construction efficiency.Prefabricated cabin substations integrate modularity, intelligence, and cost - effectiveness, boasting green, energ
Dyson
06/13/2025
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Under global climate diversity, alpine power construction faces technical and environmental challenges. Extreme climates, complex geology, and long - term low winter temperatures, along with ice, snow, and storms, strain electrical equipment stability and power facility construction (schedule, cost, maintenance). Traditional on - site substations, with long construction and poor adaptability, can’t meet alpine regions’ fast, stable power needs.Prefabricated cabin substations, as modu
Echo
06/13/2025
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Compact substation boxes, with advantages like safe operation, high reliability, and easy maintenance, are used in urban grid construction/renovation. Structurally divided into American - style (high - cost, noisy, low - efficiency, gradually phased out) and European - style (large - sized but more advantages, still popular).To address their pros/cons, ring - network prefabricated ones were developed.I. Basic Materials for Prefabricated Compact Substation BoxesMaterials need hardness, strength,
Echo
06/13/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放