• 72.5kV HV SF6 circuit breaker
72.5kV HV SF6 circuit breaker
discuss personally
Model
LW36-72.5(W)/T5000-50
LW36-72.5(W)/T4000-50
LW36-72.5(W)/T4000-40
LW36-72.5(W)/T3150-40
Basic info
Brand ROCKWILL
Model NO. 72.5kV HV Gas circuit breaker
Rated voltage 72.5kV
Rated normal current 4000A
Rated frequency 50Hz
Rated short circuit breaking current 50kA
Series LW36-72.5
Product Detail

Product introduction:

LW36-72.5 self-energy outdoor HV AC sulfur hexafluoride circuit breaker is an outdoor three-phase porcelain column electrical equipment mainly used in AC 50Hz or 60Hz, 72.5kV electricity systems in extremely cold regions (for electric stations in general regions and -42'℃ extremely cold regions). This product can be operated frequently and used as a connection circuit breaker.

Main characteristic:

  • High performance -strong rated circulating ability: strong short circuit breaking ability up to 5500A. 50kA.

  • Long service life -electrical endurance: 50kAx21times; mechanical life: 10000 times.

  • Reliable breaking performance.

  •  Reliable sealing performance; Annual leakage of SF6 gas ≤0.5%.

  • Meeting the requirements of hard running environments -suitable for Class IV polluted environments.

  • Multi-structure forms-usually porcelain column type and handcart type.

Main technical parameters:

image.png

image.png

image.png

image.png

Instructions on placing orders :  

  • Model and format of the circuit breaker.

  • Rated electrical parameters (voltage, current, breaking current, etc).

  • Working conditions for using (environment temperature, altitude, and environment pollution level).

  • Rated control circuit electrical parameters (Rated voltage of energy-store motor and Rated voltage of opening, closing coil).

  • Names and quantities of spare items needed, parts and special equipment and tools (to be otherwise ordered).

  • The wire connecting direction of the primary upper terminal.

How to choose the right type of circuit breaker?

System Voltage:

  • System Voltage: Determine the working voltage of the system and select a circuit breaker that can withstand the voltage level. High-voltage and ultra-high-voltage systems typically use SF6 gas or oil-immersed circuit breakers.

System Current:

  • System Current: Consider the maximum continuous current and short-circuit current of the system, and select a circuit breaker with sufficient rated current and short-circuit capacity.

Application Environment:

Outdoor Environment:

  • Outdoor Environment: If the circuit breaker will be installed outdoors, consider its performance in resisting pollution, moisture, and windblown sand. Tank-type circuit breakers (such as those using SF6 gas or oil) are generally more suitable for outdoor environments.

Indoor Environment:

  • Indoor Environment: For indoor installations, circuit breakers that are smaller in size and easier to maintain can be chosen, such as vacuum circuit breakers.

Insulating and Arc-Quenching Medium:

SF6 Gas:

  • SF6 Gas: Offers excellent insulating and arc-quenching performance, making it suitable for high-voltage and ultra-high-voltage systems. However, environmental concerns and leakage issues need to be addressed.

Insulating Oil:

  • Insulating Oil: Provides good insulating and heat dissipation properties, but poses fire risks and environmental pollution issues. It is suitable for applications where fire prevention requirements are not stringent.

Vacuum:

  • Vacuum: Suitable for medium and low-voltage systems, offering long life, high reliability, and ease of maintenance.


Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
The design of the three-purpose grounding transformer
The design of the three-purpose grounding transformer
Underground Power Cable Transmission LinesDirect - buried power cable lines have large ground - distributed capacitance, causing high single - phase - to - ground short - circuit capacitive current. For 10 kV lines, if this current exceeds 10 A, arcs hardly self - extinguish, risking arc overvoltage and endangering line equipment. Arc extinction is thus necessary. With a Dyn - connected main transformer, an arc - suppression coil on the secondary neutral point suffices. For Yd - connected ones,
Dyson
06/12/2025
Failure Analysis and Design Optimization of Conventional Grounding Transformers
Failure Analysis and Design Optimization of Conventional Grounding Transformers
I. Core Cause of Damage: Electrodynamic Impact (Complying with GB/T 1094.5 / IEC 60076-5)The direct cause of high-voltage winding end collapse is the instantaneous electrodynamic impact induced by short-circuit current. When a single-phase grounding fault occurs in the system (such as lightning overvoltage, insulation breakdown, etc.), the grounding transformer, as the fault current path, withstands high-amplitude and steep-rise-rate short-circuit currents. According to Ampère's force law
Felix Spark
06/12/2025
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
1 Theoretical AnalysisIn distribution networks, grounding transformers serve two key roles: powering low - voltage loads and connecting arc - suppression coils at neutrals for grounding protection. Grounding faults, the most common distribution network fault, heavily impact transformers’ operating characteristics, causing sharp changes in electromagnetic parameters and status.To study transformers’ dynamic behaviors under single - phase grounding faults, build this model: Assume a tr
Felix Spark
06/12/2025
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
1 Classification of Neutral Grounding Methods for Solar Photovoltaic Power StationsInfluenced by differences in voltage levels and grid structures across regions, the neutral grounding methods of power systems are mainly categorized into non-effective grounding and effective grounding. Non-effective grounding includes neutral grounding via arc suppression coils and neutral ungrounded systems, while effective grounding comprises neutral solid grounding and neutral grounding via resistors. The sel
Dyson
06/12/2025
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
In a neutral-insulated three-phase power system, an earthing transformer provides an artificial neutral point, which can be solidly earthed or earthed via reactors/arc suppression coils. The ZNyn11 connection is typical, where zero-sequence magnetomotive forces in the inner/outer half-windings of the same core column cancel out, balancing fault currents in series windings and minimizing zero-sequence leakage flux/impedance.Zero-sequence impedance is critical: it determines fault current magnitud
Dyson
06/12/2025
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
The neutral grounding mode refers to the connection between the power system neutral point and ground. In China's 35 kV and below systems, common methods include ungrounded neutral, arc-suppression coil grounding, and small-resistance grounding. The ungrounded mode is widely used as it allows short-term operation during single-phase grounding faults, while small-resistance grounding has become mainstream for its fast fault removal and overvoltage limitation. Many substations install grounding tr
Felix Spark
06/12/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放