• 690 W - 720 W High-power N-type TOPCON bifacial modules
  • 690 W - 720 W High-power N-type TOPCON bifacial modules
690 W - 720 W High-power N-type TOPCON bifacial modules
discuss personally
Model
WN7N-700TB-AG
WN7N-690TB-AG
WN7N-720TB-AG
Basic info
Brand Wone
Model NO. 690 W - 720 W High-power N-type TOPCON bifacial modules
Power Bifaciality 80%
Max. System Voltage 1500V (IEC)
Max. Series Fuse Rating 35 A
Module Fire Performance CLASS C
Max. power of the module 690W
Max. efficiency of Module 22.2%
Series N-type Bifacial TOPCon Technology
Product Detail

Features

  • Module power up to 720 W Module efficiency up to 23.2 %.

  • Up to 85% Power Bifaciality, more power from the back side.

  • Excellent anti-LeTID & anti-PID performance. Low power degradation, high energy yield.

  • Lower temperature coefficient (Pmax): -0.29%/°C, increases energy yield in hot climate.

  • Lower LCOE & system cost.

Standard

  • Tested up to ice ball of 35 mm diameter according to IEC 61215 standard.

  • Minimizes micro-crack impacts.

  • Heavy snow load up to 5400 Pa, wind load up to 2400 Pa*.

Engineering drawing(mm)

image.png

CS7N-695TB-AG / I-V gurves

image.png

Electrical date/STC*

image.png

Electrical date/NMOT*

image.png

Electrical date

image.png

Temperature charactheristics

image.png

What is bifacial gain in PV modules?

Definition:

Bifacial gain refers to the additional electricity generation of bifacial photovoltaic modules after they receive extra light from the environment on their back sides. This additional electricity generation is in comparison to monofacial photovoltaic modules, as monofacial photovoltaic modules can only absorb the direct light on their front sides.

Working Principle:

  • Front-side Absorption: Similar to single-sided modules, the front side of bifacial modules can absorb direct sunlight.

  • Back-side Absorption: The back side of bifacial modules is also capable of absorbing various kinds of light from the environment, including light reflected from the ground, light reflected from surrounding objects, and scattered light from the sky.

Gain Range:

Depending on different environmental conditions and installation methods, the gain of bifacial photovoltaic modules can range from 4% to 30%. The specific gain value depends on the influencing factors mentioned above.


Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Design and Application of Smart EV Charging Piles
Design and Application of Smart EV Charging Piles
As a charging pile designer deeply involved in industry projects, I've witnessed firsthand how electric vehicles (EVs) have become a pivotal force in China's new energy landscape. Decades of advancements in electronics have laid a solid foundation for EV development. The integration of V2G, energy storage technologies, and high-performance batteries not only facilitates battery swapping services but also drives the convergence of photovoltaics, energy storage, and intelligent charging systems&md
Echo
06/24/2025
Electric Vehicle Charging Pile Testing Technologies and Failure Analysis
Electric Vehicle Charging Pile Testing Technologies and Failure Analysis
1. Detection Technology for Electric Vehicle Charging PilesEV charging piles are primarily divided into two categories:DC charging pilesandAC charging piles. Let's start with DC charging piles: they communicate with the EV's battery management system (BMS) and directly charge the power battery through the DC charging interface. AC charging piles, on the other hand, rely on the EV's AC charging interface and use the vehicle-mounted charger to complete the charging process. These two types of char
Oliver Watts
06/23/2025
DC Charging Pile Enclosure Electrification Fault Inspection
DC Charging Pile Enclosure Electrification Fault Inspection
1. Fault CasesCase 1 (July 16, 2024)A district manager got a report of a charging pile outage at a square, affecting users and appliances. I, with O&M staff, found the pile was dead but charged EVs normally—yet the neutral wire/cabinet was live.Inspection steps:Relays, contactors, AC contactors checked → switching power supply had no output.Inverter, fuse, AC power tested → live current detected.Internal check: AC power and modules normal; secondary wiring intact.Cooling fan
Felix Spark
06/23/2025
Failure Analysis of Electric Vehicle AC Charging Piles
Failure Analysis of Electric Vehicle AC Charging Piles
As new energy electric vehicles become increasingly popular, the number of supporting public charging piles is growing year by year. Whether the measurement value of AC charging piles for electric vehicles is accurate is directly related to the vital interests of the vast number of electric vehicle owners. So, conducting regular mandatory inspections of charging piles is particularly important. Below, combined with relevant regulations and practical work, I’ll share some experience and pra
Felix Spark
06/23/2025
What aspects does the design of electric vehicle charging stations involve?
What aspects does the design of electric vehicle charging stations involve?
As a frontline designer, I work on EV charging piles daily. Amid worsening global climate change and China’s rapid economic growth, green mobility like e - bikes and electric cars has boomed, yet charging issues have become a focal concern. The risky “Bypass Wire” charging has spurred huge demand for professional piles. Having taken part in the CNPC First Construction residential charging pile renovation, I’m sharing my hands - on experience.I. Industry Context(1) Electri
Dyson
06/23/2025
What aspects does the inspection of industrial and commercial energy storage cover?
What aspects does the inspection of industrial and commercial energy storage cover?
As a frontline tester, I work with industrial and commercial energy storage systems daily. I know firsthand how critical their stable operation is for energy efficiency and business profitability. While installed capacity grows rapidly, equipment failures increasingly threaten ROI—over 57% of energy storage plants reported unplanned outages in 2023, with 80% stemming from equipment defects, system anomalies, or poor integration. Below, I share practical testing insights for the five core s
Oliver Watts
06/21/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!