• 550kV 740kV Gas Insulated Switchgear HV (GIS)
550kV 740kV Gas Insulated Switchgear HV (GIS)
discuss personally
Model
ZF28-550/4000-63
Basic info
Brand ROCKWILL
Model NO. 550KV 740KV GIS SF6 insulated Switchgear
Rated voltage 550kV
Rated normal current 4000A
Series ZF28
Product Detail

Product Overview:
    ZF28-550 type GIS/ ZH28-550 type HGIS is composed of standard modules through flanged joint, which can meet the demand for substation optimization design through the flexible combination between modules. It saves space and conforms to technical requests.
    This product can be applied to power system, power generation, rail transportation, petrochemical, metallurgy, mining, building materials and other large industrial consumer.

Features and advantages of the product:

  • Fully spring mechanism, high reliability.

  • Excellent breaking ability.

  • The arc extinguish of CB adopts dual break structure, and shunt capacitor to balance the voltage between open contacts, which improves the breaking ability of short-line fault and the breaking current of short circuit is 63kA.

  • E2-M2-C2 circuit breaker; E2 electrical endurance; M2 mechanical endurance.

  • Strong rated current flow capacity.

  • Excellent insulation level, low partial discharge.

  • Excellent corrosion resistance.

  • Advanced Designing tool.

  • Basin-type insolator with aluminium flange; double sealing structure.

  • Strict assembly technology.

  • The domestic first high power spring operation mechanism of circuit breaker has the small volume and is safe and stable, free of maintenance. high reliable and conform to oil free and gas free requirements for operation mechanism.

  •  Interrupter unit adopts shunt capacitor to balance the voltage between open contacts It improves short line  fault breaking capability.

  • Excellent insulation level and low partial discharge. The only company in the industry that can achieve: under the 80% power-frequency withstand voltage (80%×740kV = 592kV), the partial discharge of intervals is lower than 5pC, the partial discharge of the insulator is lower than 3pC. It’s better than the IEC standard that the partial discharge should be lower than 5pC under 1.2 times phase voltage (1.2×550/√3 = 381kV).

  • The insulator quality is stable and reliable. The basin-type insulator pouring process reaches the international advanced level.

Technical Parameters:

image.png

What are the basic requirements for GIS operation?

  • Indoor SF6 equipment room that operators often enter: ventilate at least once per shift, ventilate for 15 minutes, the air exchange volume should be greater than 3-5 times the air volume, and the air outlet should be installed in the lower part of the room; Equipment places that are not frequently visited by operators: ventilate for 15 minutes before entering.

  • During operation, the induced voltage on the shell and frame of GIS should not exceed 36V for the parts that are easily accessible to operation and maintenance personnel.

  • Temperature rise: should not exceed 30K in the part that is easily accessible to operating personnel; The part that is easily accessible to the operator but not touched during operation should not exceed 40K; Individual parts that are not easily accessible to the operator should not exceed 65K.

  • SF6 switchgear inspection at least once a day, unattended substation inspection according to regulations. During the inspection, the visual inspection is mainly carried out, and the equipment is not abnormal, and a record is made.

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Modular Intelligent Substation - Prefabricated Secondary Switchgear Integration Assembly
Modular Intelligent Substation - Prefabricated Secondary Switchgear Integration Assembly
With the development of the national economy and society, the requirements for the quality and craftsmanship of power grid projects have become increasingly stringent. The need to improve the construction progress and quality of substations has created opportunities for the promotion of prefabricated cabin - type intelligent substations. The traditional on - site wiring and commissioning of secondary substation equipment involve a large amount of work. Moreover, on - site construction has to wai
Echo
06/13/2025
Application of Pre-integrated Prefabricated Substations in Renewable Energy Sector
Application of Pre-integrated Prefabricated Substations in Renewable Energy Sector
Against the backdrop of profound changes in the global energy landscape and the booming development of the new energy industry, the construction mode of traditional substations struggles to meet the rapid deployment needs of new energy projects. The modular intelligent prefabricated cabin substation, leveraging its innovative advantages, has become a key direction for optimizing the new energy power system. In - depth exploration of its technical principles, industry adaptability, and applicatio
Echo
06/13/2025
Research on Reliability Enhancement Scheme Implementation for Modular Intelligent Prefabricated Substations
Research on Reliability Enhancement Scheme Implementation for Modular Intelligent Prefabricated Substations
1 Implementation Strategies for the Scheme1.1 Deepen Survey and ResearchBefore constructing prefabricated cabin - type substations, it is necessary to conduct detailed surveys of local working conditions, clarify the construction scale and objectives, evaluate existing power facilities, plan projects, make up for infrastructure shortcomings, and adjust the construction rhythm. Meanwhile, control costs to avoid project suspension.1.2 Strengthen Structural ConstructionDuring promotion, multi - dim
Echo
06/13/2025
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
The secondary equipment area of conventional substations uses reinforced concrete or prefabricated steel structures, facing issues like long construction cycles, unreasonable functional zone design, strict environmental assessments, dust, noise, and disturbances. Primary and secondary equipment can only be installed after civil works and decoration, lowering construction efficiency.Prefabricated cabin substations integrate modularity, intelligence, and cost - effectiveness, boasting green, energ
Dyson
06/13/2025
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Under global climate diversity, alpine power construction faces technical and environmental challenges. Extreme climates, complex geology, and long - term low winter temperatures, along with ice, snow, and storms, strain electrical equipment stability and power facility construction (schedule, cost, maintenance). Traditional on - site substations, with long construction and poor adaptability, can’t meet alpine regions’ fast, stable power needs.Prefabricated cabin substations, as modu
Echo
06/13/2025
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Compact substation boxes, with advantages like safe operation, high reliability, and easy maintenance, are used in urban grid construction/renovation. Structurally divided into American - style (high - cost, noisy, low - efficiency, gradually phased out) and European - style (large - sized but more advantages, still popular).To address their pros/cons, ring - network prefabricated ones were developed.I. Basic Materials for Prefabricated Compact Substation BoxesMaterials need hardness, strength,
Echo
06/13/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放