• 40.5kV HV Vacuum SF6 circuit breaker
40.5kV HV Vacuum SF6 circuit breaker
discuss personally
Model
ZW39-40.5/2500-31.5
ZW39-40.5/2000-31.5
Basic info
Brand Wone
Model NO. 40.5kV HV Vacuum SF6 circuit breaker
Rated voltage 40.5kV
Rated normal current 2000A
Rated frequency 50Hz
Rated short circuit breaking current 31.5kA
Series ZW39-40.5
Product Detail

Product introduction:

ZW39-40.5 vacuum circuit breaker is applicable in the 50Hz,40,5kV three-0hase electrical system and it is used forbreaking rated current, failure current or switching lines and realize the control and protection of electrical system,This product can be frequently operated and can also be used as a connection breaker.

Main characteristic:

  • The optimized choice of vacuum interrupter contact materials keeps the breaking interception value under 4A on average, effectively inhibiting operation overvoltage.

  •  The circuit breaker has strong breaking capacity and the breaking short-circuit current 31.5kV can reach 30 times.

  •  Equipped with CT34 improved spring operating mechanism, using cast aluminum base, good stability, mechanical life of more than 10000 times. Main features of CT34 improved structure (compared with original CT10A structure).

    (a)The energy storage system adopts floating tooth structure. After closing, the remaining energy of the closing spring will continue to store energy and act as the closing buffer. There is no void, the energy storage time is short, and the energy storage can be in place within 8S;

    (b)Operating mechanism adopts high strength cast aluminum frame, which has high strength, no welding stress and nigh anti-corrosion performance;

    (c)The opening and closing spring and buffer are arranged in a centralized way, with compact structure and beautiful appearance;

    (d)Imported Krupp NB52 grease is used for the mechanism, which is resistant to low temperature and not easy to harden, and is suitable for -50℃~+55°℃ area;

    (e)The mechanism adopts oil buffer, small operation impact, small brake rebound.

  •  This product can meet the environment requirements for a sea level of up to 3000m; with a high insulation level, the insulation level at broken sections reaches 118kV;

  • The circuit breaker may have internally or externally attached transformers. Four internally attached transformers can be attached to each phase of the circuit beaker and the iron core of the internally attached transformer adopts microcrystal alloy and magnetic material with high conductivity, and the electrical transformers above 200A can reach Grade 0.2 or Grade0.2S. The integrated structure of the circuit breaker is compact, and the binding techniques for the secondary windings of transformers have been fully optimized, which fully ensures that after binding the coils of the transformer has regular shape, free of burrs, and they will not become loosen at baking and not deformed after they are installed into the main unit, thus ensuring even electrical field.

  •  The internally attached CT of the circuit breaker is compact, but due to the limited space inside the circuit breaker, it cannot realize very high accuracies (for example 0.2 or 0.2s. ) at small currents (such as those below 100A), and it also has small load. ln addition, the maintenance, capacity increase and replacement of internally attached current transformer is not convenient compared with those of the externally attached transformer.

  •  In the space between the vacuum interrupter and the ceramic sleeve of this product is filled with SF6 gas (without internally attached CT: 0.02MPa, with internally attached CT: 0.2pa), ensuring that no internal condensation and moisture absorption will occur,

  •  Imported products or products made by joint venture manufacturers were adopted for major secondary electric components, so they feature high reliability.

  • The surface treatments for the exposed parts of this product were al hot dip galvanized or directly use high quality stainless steel plates, which feature excellent corrosion resistance.

Main technical parameters:

1732503263140.png

Order notice :

  • Types and specifications of circuit breakers;

  • Rated electrical parameters (voltage, current and breaking current, etc.);

  • Ambient conditions (ambient temperatures, sea levels and grades of environmental pollution level);

  • Operating voltage and motor voltage of operating mechanism;

  • Number, current ratios, scale order combination and secondary load of internally or externally attached transformer;

  •  Spare parts and specialized tools, names and quantity of equipment (need to be ordered separately).

How does a vacuum SF6 circuit breaker work?

Closing Process:

  • Closing Process: When the operating mechanism receives a closing command, it drives the moving contact towards the stationary contact until they make contact and close tightly, thus completing the circuit. During the closing process, the contact pressure between the contacts must reach a certain value to ensure good electrical conductivity and mechanical stability, preventing issues such as overheating and loosening of the contacts during operation.

Opening Process:

  • Opening Process: During the opening process, the operating mechanism rapidly moves the moving contact away from the stationary contact, creating an arc between the contacts. At this point, the insulating medium in the arc quenching chamber (such as sulfur hexafluoride gas) rapidly decomposes and ionizes under the high temperature of the arc, forming a plasma. The positive and negative ions in the plasma move in opposite directions under the influence of the electric field, causing the arc to cool and stretch, ultimately leading to its extinction and the disconnection of the circuit.


Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Phasor Method for Solving Parallel Circuits
Phasor Method for Solving Parallel Circuits
When dealing with parallel circuits, multiple branches are connected in parallel. Each branch contains components such as resistors, inductors, and capacitors, forming a series circuit within that branch. Each branch is first analyzed separately as a series circuit, and then the effects of all branches are combined.In circuit calculations, both the magnitude and phase angle of current and voltage are taken into account. When solving the circuit, the magnitudes and phase angles of voltages and cu
Edwiin
05/30/2025
Permanent Magnet Moving Coil or PMMC Instrument
Permanent Magnet Moving Coil or PMMC Instrument
DefinitionInstruments that utilize a permanent magnet to generate a stationary magnetic field within which a coil moves are known as Permanent Magnet Moving Coil (PMMC) instruments. They operate on the principle that torque is exerted on a moving coil situated in the magnetic field of a permanent magnet. PMMC instruments provide accurate results for direct current (DC) measurements.Construction of PMMC InstrumentThe moving coil and the permanent magnet are the key components of a PMMC instrument
Edwiin
05/30/2025
Difference Between Porcelain and Glass Insulators
Difference Between Porcelain and Glass Insulators
Key Differences Between Glass and Porcelain InsulatorsBoth porcelain and glass insulators are widely applied in power transmission and distribution to insulate overhead line conductors from supporting towers and poles. With extended service lives and suitability for high voltage ratings, their unique characteristics and properties define their distinct application scenarios.Porcelain InsulatorsPorcelain, a ceramic material, is valued for its absence of internal defects such as voids, cracks, or
Edwiin
05/30/2025
What is Static VAR Compensator (SVC)? Circuit & Operation in PF Correction
What is Static VAR Compensator (SVC)? Circuit & Operation in PF Correction
What is a Static VAR Compensator (SVC)?A Static VAR Compensator (SVC), also termed a Static Reactive Compensator, is a critical device for enhancing the power factor in electrical power systems. As a type of static reactive power compensation equipment, it injects or absorbs reactive power to maintain optimal voltage levels, ensuring stable grid operation.An integral part of the Flexible AC Transmission System (FACTS), an SVC comprises a bank of capacitors and reactors controlled by power electr
Edwiin
05/30/2025
Comparison Between Overhead & Underground Transmission Systems
Comparison Between Overhead & Underground Transmission Systems
Key Differences and Comparison Between Underground and Overhead Power Transmission & DistributionPublic SafetyIn terms of public safety, underground systems outperform overhead transmission systems. With all transmission and distribution components buried, underground setups minimize risks from obstacles and external interference. Additionally, they are less susceptible to environmental factors like wind, storms, and heavy rain, making them inherently more secure.Initial CostUnderground syst
Edwiin
05/30/2025
What is the Difference Between Shunt Reactor and Shunt Capacitor?
What is the Difference Between Shunt Reactor and Shunt Capacitor?
In an electrical power system, various devices are utilized to enhance power factor and operational efficiency. Shunt capacitors and shunt reactors represent two distinct components designed to optimize the performance of electrical grids. This article explores their key differences, beginning with an overview of their fundamental principles.Shunt CapacitorsA shunt capacitor refers to a single capacitor or a group of capacitors (termed a capacitor bank) connected in parallel to the power system.
Edwiin
05/30/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放