• 100 kVA Single Phase Pole Mounted Transformer
100 kVA Single Phase Pole Mounted Transformer
discuss personally
Model
DR11-100/10
Basic info
Brand Vziman
Model NO. 100 kva Single Phase Pole Mounted Transformer
Rated capacity 100kVA
Series Single Phase Pole Mounted Transformer
Product Detail

Product Overview

A professional distribution transformer manufacturer with 10 years of expertise, specializes in single-phase pole-mounted transformers for urban and rural power distribution. Designed for 11kV, 12.4kV, 13.2kV, 13.8kV, and 34.5kV input voltages, these transformers deliver outputs such as 240/480V and 120/240V, complying with IEEE C57, ANSI C57, and IEC 60076 standards.

Leading Technological Advantages

  • Enhanced Lightning Resistance: Unique winding technology minimizes surge damage.

  • Superior Mechanical Strength: Low magnetic leakage design with 45° full-oblique step-laminated iron core structure resists short circuits.

Shell & Construction

Precision Manufacturing:

  • Mitsubishi laser cutting and CNC punching ensure mm-level accuracy.

  • ABB robotic welding with laser detection achieves a 99.99998% leak-proof rate.

  • Durable Coating: Electrostatic spray paint offers 50+ years of corrosion resistance (100h salt spray test, hardness ≥0.4).

  • Fully Sealed Design: Cylindrical structure with self-sealing manual pressure relief valve (ANSI-compliant), NEMA-standard hanger brackets, and 30+ year maintenance-free operation.

Core Components

Iron Core

  • High-quality cold-rolled grain-oriented silicon steel sheets from Baowu Steel (China), with mineral oxide insulation.

  • Precision cutting and stacking reduce no-load current, losses, and noise.

Windings

  • Low Voltage: High-grade cable paper-wrapped wires.

  • High Voltage: Polyurethane enamelled round copper wires.

  • Interlayer insulation with dot-adhesive paper ensures coil stability and insulation resistance.

Premium Materials

  • Silicon steel sheets: Baowu Steel Group.

  • Oxygen-free copper: Chinese high-purity grade.

  • Transformer oil: CNPC Kunlun 25# premium oil.

Additional Features

  • High-strength polymer or porcelain low/high-voltage bushings.

  • Ring-type full-copper tinned terminals.

  • Integrated current-limiting fuses and arresters for surge protection.

Product parameters:

  • Capacity: 100kVA 

  • Rated voltage: 13.8kV, 34.5kV

  • Maximum operating voltage (kV) 38.5kV

  • Conditions of use:

  • The temperature:
    Maximum daily temperature (℃) : 40; Minimum daily temperature (℃) : -25; Maximum daily temperature difference (K) : 25; Average temperature of the hottest month (℃) : 30; Maximum annual average temperature (℃) : 20; Average daily relative humidity (≤%) : 95; Average monthly relative humidity (≤%) : 90 

  • Altitude (≤m) : 1000

  • Solar radiation intensity (W/cm2) : 0.1

  • Maximum ice thickness (mm) : 10

  • 10m high from the ground, maintain 10min average maximum wind speed (m/s) : 35

  • Ground horizontal acceleration (M/S2) : 2

  • Installation place: outdoor; 8. Pollution grade: ⅲ

image.png

Ordering instructions:

  • Main parameters of transformer (voltage, capacity, loss and other main parameters) .

  • Transformer use environment (altitude, temperature, humidity, place, etc) .

  • Other customized requirements (tap switch, color, oil pillow, etc) .

  • The minimum order quantity is 1 set, global delivery within 7 days .

  •  The normal delivery period is 30 days, with fast delivery worldwide .

What are the advantages of a single-phase pole-mounted transformer?

  • High Efficiency:Utilizes premium winding materials and advanced manufacturing techniques to achieve superior energy conversion efficiency, reducing operational losses.

  • Low Loss Performance:Constructed with high-grade silicon steel sheets and precision processes, minimizing no-load and load losses for enhanced energy savings and environmental friendliness.

  • Extended Service Life:Premium materials and rigorous manufacturing standards ensure prolonged durability, reducing replacement needs over the product lifecycle.

  • Low Noise Operation:Optimized core and coil design significantly reduces operational noise, making it ideal for noise-sensitive environments like urban areas or commercial buildings.

  • Reliable Performance:Oil-immersed design offers excellent cooling and insulation capabilities, ensuring stable operation in high-power, high-voltage applications.

  • Enhanced Fire Safety:Despite oil-based insulation, modern designs incorporate multi-layer protective measures (e.g., pressure relief valves, fire-retardant coatings) to mitigate risks.

  • Robust Environmental Adaptability:Engineered to withstand harsh conditions, including extreme temperatures, high humidity, and rugged terrain, for versatile deployment.

Know your supplier
Vziman
Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150000000
Professional Experience
3 years
Workplace
10000m²
占位
占位
Related Products
Related Knowledges
What are the reasons for low insulation at the low-voltage side of a dry-type transformer?
What are the reasons for low insulation at the low-voltage side of a dry-type transformer?
Hi everyone, I’m Felix, and I’ve been working in electrical equipment fault repair for 15 years.Over these years, I’ve traveled across factories, substations, and distribution rooms all over the country, troubleshooting and repairing all kinds of electrical equipment. Dry-type transformers are among the most common devices we deal with.Today, a friend asked me:“What does it mean when the low-voltage side of a dry-type transformer has low insulation resistance?”Great
Felix Spark
07/01/2025
What tests are required for dry-type transformers?
What tests are required for dry-type transformers?
1 Pre - commissioning InspectionAs a front - line tester, before formally commissioning a dry - type transformer, I need to carry out a comprehensive and systematic inspection. First, I conduct a visual inspection of the transformer body and its accessories, carefully checking for mechanical damage or deformation. Then, I check whether the leads of the high - and low - voltage windings are firmly connected and whether the bolt tightening torque meets the standard requirements (usually 40 - 60N&m
Oliver Watts
07/01/2025
What aspects need attention during the installation of dry-type transformers?
What aspects need attention during the installation of dry-type transformers?
1 Pre - installation PreparationAs a front - line installer, I know very well that the preparation work before installing a dry - type transformer must be thorough. First, I will carefully review the design drawings and technical documents, and check one by one the technical parameters such as the model specification, rated capacity, and voltage level of the transformer to ensure they are in full compliance with the design requirements. Then, I will conduct an unpacking inspection of the transfo
James
07/01/2025
What are the causes of dry-type transformers burning out during operation?
What are the causes of dry-type transformers burning out during operation?
1 Fault PhenomenonI am engaged in front - line fault maintenance work, and recently encountered problems with dry - type transformers. Dry - type transformers have a simple structure, are convenient for transportation, and easy for maintenance. They are widely used in power distribution places with relatively high environmental protection requirements. Because of their good fire - resistance, they can be installed in load - center areas to reduce voltage loss and power loss.The property manageme
Felix Spark
07/01/2025
Method for Automatic Isolation of Customer Equipment Faults by Load Switches in Distribution Networks
Method for Automatic Isolation of Customer Equipment Faults by Load Switches in Distribution Networks
1 OverviewDistribution network safety has long been under - addressed, with its automation lagging substation automation . Using 10 kV intervals of existing substations to set line section points meets future grid needs . Configuration of distribution switches, section switches, and protection must match substation outgoing - line protection for reliability. Fault isolation, self - healing, and restoration are key to distribution automation .Scholars have studied smart distribution network fault
Felix Spark
06/30/2025
A Novel Detection Method for Stuck Faults in Load Switches
A Novel Detection Method for Stuck Faults in Load Switches
In recent years, as distribution automation advances, load switches see wider use in distribution lines. Yet, mechanical - failure - induced accidents are on the rise, burdening line operation and maintenance.Poor mechanical performance is the main cause of switch faults. Many scholars study large - scale switchgear operation, using methods like coil current detection, vibration signal analysis, switch travel testing, ultrasonic flaw detection, and infrared thermometry. Motor - current - based s
Oliver Watts
06/30/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!