• 31.5kV indoor railways vacuum circuit breaker
31.5kV indoor railways vacuum circuit breaker
discuss personally
Model
GSR+-31.5-2500
Basic info
Brand ABB
Model NO. 31.5kV indoor railways vacuum circuit breaker
Rated voltage 31.5kV
Rated normal current 2500A
Rated frequency 50/60Hz
Series GSR+
Product Detail

Description:

Medium Voltage single-phase circuit breaker with magnetic actuator, designed for railway power supply up to 27.5 kV, 2500 A, 31.5 kA

With a rated voltage of 31.5kV, it can effectively handle the electrical loads in railway applications. Equipped with brushless servomotors (one per phase) and double encoders, it enables precise control over switching operations. Each phase also has an electronic controller that communicates hierarchically, ensuring coordinated and reliable system operation. This breaker is designed to safeguard the railway electrical network from overloads and short - circuits, ensuring stable and safe power supply for trains and related facilities.

The GSR+ II range is the first commercially available single-phase vacuum circuit breaker for railway power supply applications to feature a vacuum interrupter, magnetic actuator and electronic controller. This solution is robust, reliable and essentially maintenance-free. 

Feature:

  • High Voltage Adaptability and Stable Insulation: With a rated voltage of 31.5kV, it is suitable for high-voltage environments in railway power systems. The three-pole structure encapsulated in epoxy resin, with built-in vacuum interrupters, offers excellent insulation performance and can withstand harsh environmental factors such as moisture and dust.
  • Precision Control Operation: Each phase is equipped with a brushless servo motor and dual encoders to achieve high-precision control of switching operations. It can quickly and stably respond to the on/off demands of the power system, ensuring the timeliness of power supply.
  • Intelligent Collaborative Operation: The electronic controllers of each phase have hierarchical communication functions, enabling mutual collaboration and linkage with the main control unit. This ensures that the circuit breaker can coordinate consistently and operate stably and reliably under complex working conditions.
  • Efficient Fault Protection: It has the ability to quickly cut off overloads, short circuits, and other faults, effectively protecting the railway electrical network. This avoids the impact of power faults on train operation safety and ensures the stability of the railway power supply system.
  • Compact Indoor Design: Optimized for indoor installation, its compact structure saves space, adapts to the limited installation environments in railway substations and control rooms, and facilitates integration and maintenance.

 Technical Characteristics:

 

Know your supplier
ABB
As an authorized distributor of ABB products, we take great pride in our partnership.
Main Categories
High voltage/Low voltage
Business Type
Sales
Highest Annual Export (USD)
$580000000
Professional Experience
11 years
Workplace
20000m²
占位
占位
FAQ
Q: What are the differences between indoor vacuum circuit breakers and SF₆ circuit breakers?
A: Arc-quenching medium: Vacuum circuit breakers use vacuum for arc quenching (environmentally friendly, no greenhouse gases), while SF₆ circuit breakers use SF₆ gas (requiring attention to gas leakage and environmental treatment). Volume and maintenance: Vacuum circuit breakers are smaller in size and have a longer maintenance cycle (the maintenance-free cycle can reach 10 years); SF₆ circuit breakers require regular detection of gas pressure.
Q: What are the precautions for installing indoor vacuum circuit breakers?
A: Ensure the installation environment is dry, free of corrosive gases, and well-ventilated (meeting the IP4X protection class requirements). Check that the dimensions of the switchgear cabinet match those of the circuit breaker (e.g., withdrawable types need to be compatible with the switchgear rails), and fasten the connection terminals securely to prevent loosening and overheating. The insulation distance of the primary circuit must meet the standards (e.g., for 12kV products, the phase-to-phase and phase-to-ground clearances shall be ≥125mm).
Related Products
Related Knowledges
Modular Intelligent Substation - Prefabricated Secondary Switchgear Integration Assembly
Modular Intelligent Substation - Prefabricated Secondary Switchgear Integration Assembly
With the development of the national economy and society, the requirements for the quality and craftsmanship of power grid projects have become increasingly stringent. The need to improve the construction progress and quality of substations has created opportunities for the promotion of prefabricated cabin - type intelligent substations. The traditional on - site wiring and commissioning of secondary substation equipment involve a large amount of work. Moreover, on - site construction has to wai
Echo
06/13/2025
Application of Pre-integrated Prefabricated Substations in Renewable Energy Sector
Application of Pre-integrated Prefabricated Substations in Renewable Energy Sector
Against the backdrop of profound changes in the global energy landscape and the booming development of the new energy industry, the construction mode of traditional substations struggles to meet the rapid deployment needs of new energy projects. The modular intelligent prefabricated cabin substation, leveraging its innovative advantages, has become a key direction for optimizing the new energy power system. In - depth exploration of its technical principles, industry adaptability, and applicatio
Echo
06/13/2025
Research on Reliability Enhancement Scheme Implementation for Modular Intelligent Prefabricated Substations
Research on Reliability Enhancement Scheme Implementation for Modular Intelligent Prefabricated Substations
1 Implementation Strategies for the Scheme1.1 Deepen Survey and ResearchBefore constructing prefabricated cabin - type substations, it is necessary to conduct detailed surveys of local working conditions, clarify the construction scale and objectives, evaluate existing power facilities, plan projects, make up for infrastructure shortcomings, and adjust the construction rhythm. Meanwhile, control costs to avoid project suspension.1.2 Strengthen Structural ConstructionDuring promotion, multi - dim
Echo
06/13/2025
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
The secondary equipment area of conventional substations uses reinforced concrete or prefabricated steel structures, facing issues like long construction cycles, unreasonable functional zone design, strict environmental assessments, dust, noise, and disturbances. Primary and secondary equipment can only be installed after civil works and decoration, lowering construction efficiency.Prefabricated cabin substations integrate modularity, intelligence, and cost - effectiveness, boasting green, energ
Dyson
06/13/2025
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Under global climate diversity, alpine power construction faces technical and environmental challenges. Extreme climates, complex geology, and long - term low winter temperatures, along with ice, snow, and storms, strain electrical equipment stability and power facility construction (schedule, cost, maintenance). Traditional on - site substations, with long construction and poor adaptability, can’t meet alpine regions’ fast, stable power needs.Prefabricated cabin substations, as modu
Echo
06/13/2025
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Compact substation boxes, with advantages like safe operation, high reliability, and easy maintenance, are used in urban grid construction/renovation. Structurally divided into American - style (high - cost, noisy, low - efficiency, gradually phased out) and European - style (large - sized but more advantages, still popular).To address their pros/cons, ring - network prefabricated ones were developed.I. Basic Materials for Prefabricated Compact Substation BoxesMaterials need hardness, strength,
Echo
06/13/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放