• 3 Phase AC Power Voltage Stabilizer 50kVA 100kVA 200kVA 500kVA 2000kVA 380V 415V Automatic Adjustment Voltage Regulator
  • 3 Phase AC Power Voltage Stabilizer 50kVA 100kVA 200kVA 500kVA 2000kVA 380V 415V Automatic Adjustment Voltage Regulator
  • 3 Phase AC Power Voltage Stabilizer 50kVA 100kVA 200kVA 500kVA 2000kVA 380V 415V Automatic Adjustment Voltage Regulator
3 Phase AC Power Voltage Stabilizer 50kVA 100kVA 200kVA 500kVA 2000kVA 380V 415V Automatic Adjustment Voltage Regulator
$4260.00
Model
SBT-S-800KVA
SBT-S-600KVA
SBT-S-500KVA
SBT-S-400KVA
SBT-S-320KVA
SBT-S-300KVA
SBT-S-250KVA
SBT-S-225KVA
SBT-S-200KVA
SBT-S-180KVA
SBT-S-150KVA
SBT-S-120KVA
SBT-S-100KVA
SBT-S-80KVA
SBT-S-60KVA
SBT-S-30KVA
Basic info
Brand Vziman
Model NO. 3 Phase AC Power Voltage Stabilizer 50KVA 100KVA 200KVA 500KVA 2000KVA 380V 415V Automatic Adjustment Voltage Regulator
Rated capacity 150KVA
Series SWB-S
Product Detail

Description:

SBW-S、DBW-S series intelligent numerical control (microcomputer type) compensated AC power regulators are based on the perfect combination of traditional high-power compensated voltage regulators and modern intelligent control technology, allowing users to enjoy the reliability and convenience of parameter setting and maintenance brought by modern advanced control circuits, highlighting the safety, stability Energy saving and humanization of man-machine interface. The regulated power supply can be equipped with a variety of intelligent interfaces to realize the functions of "remote signaling, telemetry and remote control".

Features:

  • Delay output function (add output contactor).

  • Lightning protection device: it can provide good surge protection in case of instantaneous change of power grid and induced lightning stroke.

  • EMI filtering device: it can effectively filter the harmonic interference of power grid.

  • Phase sequence and phase loss protection function.

  • RS485 interface: realize remote control, remote signaling and telemetry function.

It can be widely used in industrial and mining enterprises, scientific research, posts and telecommunications, military, railway, transportation, hospitals, elevators, bowling equipment, air conditioners, hotels and other places with high requirements for power grid power supply.The normal operating conditions of sbw-s and dbw-s series intelligent control (single chip microcomputer control) complementary AC power regulators are:

  • temperature:-15°C - 40°C.

  • Altitude:less than 1000m.

  • Relative humidity:<90%.

  • The relative humidity installation site shall be free of gas, steam, chemical deposition, dust, dirt and other explosive and corrosive media that seriously affect the insulation strength of regulated power supply.

  • The installation site shall be free from serious vibration and turbulence.

  • Any special use conditions that do not meet the above provisions shall be determined through consultation with the user and our factory.

Parameters:

image.png

image.png

Wiring diagram:

SBW-S、DBW-S series intelligent numerical control (single chip microcomputer control) compensation AC power regulator is mainly composed of input circuit breaker QF, three-phase voltage regulating transformer TB, three-phase voltage regulating transformer TVV, servo motor control and transmission mechanism, voltage stabilizing / bypass transfer switch and protection circuit. The electrical principle of the main circuit is shown in the figure below.

企业微信截图_17213497118363.png

企业微信截图_17213498418096.png


  • Voltage stabilizing indicator.

  • Intelligent control display.

  • Stop button.

  • Main power switch.

  • Control circuit fuse.

  • Control power transformer.

  • Mains / voltage stabilizing transfer switch.

  • Voltage regulating transformer (auxiliary transformer).

  • Input terminal block.

  • Output terminal block.

  • Compensation transformer (main transformer).

  • Inlet and outlet holes (knock off holes).


What is the co-operation principle of the three-phase AC power regulator?

Working Principle:

The working principle of a three-phase AC voltage stabilizer mainly includes the following steps:

Input Voltage Detection: The voltage stabilizer first detects the input three-phase AC voltage.

Voltage Comparison: The detected input voltage is compared with the preset target voltage.

Adjusting Circuit: Based on the result of the voltage comparison, the voltage stabilizer adjusts the output voltage through the adjusting circuit. Common adjustment methods include:

  • Voltage-Regulating Transformer: Adjusting the voltage by changing the turns ratio of the transformer.

  • Servo Motor Drive: Driving the carbon brush to move on the sliding rheostat by the servo motor to change the resistance value and thus adjust the voltage.

  • Electronic Control: Using electronic components (such as thyristors, IGBTs, etc.) to adjust the voltage.


Output Voltage Stabilization: The adjusted voltage is supplied to the load through the output port to ensure that the output voltage remains stable within the predetermined range.

Know your supplier
Vziman
Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150000000
Professional Experience
3 years
Workplace
10000m²
占位
占位
Related Products
Related Knowledges
Modular Intelligent Substation - Prefabricated Secondary Switchgear Integration Assembly
Modular Intelligent Substation - Prefabricated Secondary Switchgear Integration Assembly
With the development of the national economy and society, the requirements for the quality and craftsmanship of power grid projects have become increasingly stringent. The need to improve the construction progress and quality of substations has created opportunities for the promotion of prefabricated cabin - type intelligent substations. The traditional on - site wiring and commissioning of secondary substation equipment involve a large amount of work. Moreover, on - site construction has to wai
Echo
06/13/2025
Application of Pre-integrated Prefabricated Substations in Renewable Energy Sector
Application of Pre-integrated Prefabricated Substations in Renewable Energy Sector
Against the backdrop of profound changes in the global energy landscape and the booming development of the new energy industry, the construction mode of traditional substations struggles to meet the rapid deployment needs of new energy projects. The modular intelligent prefabricated cabin substation, leveraging its innovative advantages, has become a key direction for optimizing the new energy power system. In - depth exploration of its technical principles, industry adaptability, and applicatio
Echo
06/13/2025
Research on Reliability Enhancement Scheme Implementation for Modular Intelligent Prefabricated Substations
Research on Reliability Enhancement Scheme Implementation for Modular Intelligent Prefabricated Substations
1 Implementation Strategies for the Scheme1.1 Deepen Survey and ResearchBefore constructing prefabricated cabin - type substations, it is necessary to conduct detailed surveys of local working conditions, clarify the construction scale and objectives, evaluate existing power facilities, plan projects, make up for infrastructure shortcomings, and adjust the construction rhythm. Meanwhile, control costs to avoid project suspension.1.2 Strengthen Structural ConstructionDuring promotion, multi - dim
Echo
06/13/2025
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
The secondary equipment area of conventional substations uses reinforced concrete or prefabricated steel structures, facing issues like long construction cycles, unreasonable functional zone design, strict environmental assessments, dust, noise, and disturbances. Primary and secondary equipment can only be installed after civil works and decoration, lowering construction efficiency.Prefabricated cabin substations integrate modularity, intelligence, and cost - effectiveness, boasting green, energ
Dyson
06/13/2025
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Under global climate diversity, alpine power construction faces technical and environmental challenges. Extreme climates, complex geology, and long - term low winter temperatures, along with ice, snow, and storms, strain electrical equipment stability and power facility construction (schedule, cost, maintenance). Traditional on - site substations, with long construction and poor adaptability, can’t meet alpine regions’ fast, stable power needs.Prefabricated cabin substations, as modu
Echo
06/13/2025
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Compact substation boxes, with advantages like safe operation, high reliability, and easy maintenance, are used in urban grid construction/renovation. Structurally divided into American - style (high - cost, noisy, low - efficiency, gradually phased out) and European - style (large - sized but more advantages, still popular).To address their pros/cons, ring - network prefabricated ones were developed.I. Basic Materials for Prefabricated Compact Substation BoxesMaterials need hardness, strength,
Echo
06/13/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放