• 420kV Dead tank SF6 circuit breaker
420kV Dead tank SF6 circuit breaker
discuss personally
Model
LW-420-5000
Basic info
Brand ROCKWILL
Model NO. 420kV Dead tank SF6 circuit breaker
Rated voltage 420kV
Rated normal current 5000A
Rated frequency 50/60Hz
Series LW
Product Detail

Description:

420kV Dead tank SF6 circuit breaker products are composed of inlet and outlet bushings, current transformers, interrupters, frames, operating mechanisms and other componentsIt is used to cut off the rated current, fault current or conversion line to realize the control and protection of the power system, and is widely used in domestic and overseas electric power, metallurgy, mining, transportation and public utilities industries.

Main Features:

  • High-Efficiency Arc Extinction and Insulation: Utilizes SF6 gas for rapid arc extinction and excellent insulation performance, capable of quickly interrupting fault currents to ensure stable operation of power systems at the 420kV voltage level.
  • Robust Sealed Structure: Adopts a dead-tank design, sealing live components within a metal tank filled with SF6 gas to isolate them from the external environment. Features outstanding seismic resistance and dust-proof capability, adapting to complex environments.
  • Integrated Multifunctionality: Integrates components such as bushings and current transformers, combining functions like current measurement and protection control to simplify system configuration and improve operation and maintenance efficiency.
  • Long Lifespan and Low Maintenance: Exhibits long mechanical and electrical service lives. The sealed structure effectively reduces component aging and corrosion, significantly decreasing maintenance frequency and saving operational costs.
  • Multiple Safety Protections: Equipped with anti-misoperation interlocking devices and comprehensive insulation protections to effectively prevent human errors and fully safeguard the safety of personnel and equipment during operation.

Technical specifications:

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Development of an Outdoor Integrated Low - Voltage Current Transformer
Development of an Outdoor Integrated Low - Voltage Current Transformer
In power grid construction, line losses reflect planning, design, and operation management. They’re key for evaluating power systems. For refined low - voltage transformer area line loss management, accurate line loss counting is critical. So, solidifying basic data, ensuring data accuracy, and proper original data collection matter for analysis. We must also optimize factors affecting collection accuracy, make preventive measures, and boost refined line loss management.1 Current Status of
Dyson
07/05/2025
What might be the future development trends of outdoor current transformers?
What might be the future development trends of outdoor current transformers?
I'm Echo, a 12-Year Veteran in the CT Industry, Talking About What's Coming NextHi everyone, I'm Echo, and I've been working in the current transformer (CT) industry for 12 years.From learning wiring and equipment debugging with my mentor to now leading a team tackling complex on-site issues, I've witnessed many technological advancements and industry changes. Especially with outdoor current transformers, there have been significant developments, but also much room for improvement.A few days ago
Echo
07/05/2025
Ratio Trial Verification Method for Current Transformers
Ratio Trial Verification Method for Current Transformers
Fellow electric power calibration workers, you must have encountered this situation: The nameplate of an outdoor current transformer has been tormented by wind, sun, rain, and freezing, to the point where the transformation ratio is indistinguishable! Don't panic, we have a solution - use a current transformer calibrator and through the “transformation ratio trial calibration method”, we can figure out the actual transformation ratio and errors clearly. Here, taking the SHGQ - DC typ
Oliver Watts
07/05/2025
Why Does the Secondary Insulation of Outdoor Current Transformers Drop?
Why Does the Secondary Insulation of Outdoor Current Transformers Drop?
I'm Felix, a 15-Year Veteran in the CT Industry, Sharing What You Need to Watch Out ForHi everyone, I'm Felix, and I've been working with current transformers (CTs) for over 15 years. Today, let’s talk about why the secondary insulation of outdoor CTs sometimes drops, and what you can do to prevent it.Common Causes:1. Moisture Ingress — Poor Sealing is the Biggest Problem!Outdoor CTs are constantly exposed to wind and rain. If the sealing isn't tight enough, moisture can get inside a
Felix Spark
07/05/2025
What tests need to be conducted on current transformers?
What tests need to be conducted on current transformers?
By Oliver, 8 Years in the Electrical IndustryHi everyone, I'm Oliver, and I've been working in the electrical industry for 8 years.From early days doing substation equipment commissioning to now managing protection and metering configurations for entire distribution systems, one of the most frequently used devices in my work has been the Current Transformer (CT).Recently, a friend who's just starting out asked me:“How do you test current transformers? Is there a simple and effective way to
Oliver Watts
07/04/2025
What should be noted when choosing a current transformer for a 10kV station transformer circuit?
What should be noted when choosing a current transformer for a 10kV station transformer circuit?
Practical Experience Sharing from an Electrical Engineer in the FieldBy James, 10 Years in the Electrical IndustryHi everyone, I'm James, and I've been working in the electrical industry for 10 years.From early involvement in substation design and equipment selection, to later taking charge of relay protection and automation system commissioning for entire projects, one of the most frequently used devices in my work has been the current transformer (CT).Recently, a friend who's just starting out
James
07/04/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!