• Ladle refining furnace transformer(distribution transformer)
Ladle refining furnace transformer(distribution transformer)
discuss personally
Model
SLR11-20000
Basic info
Brand Vziman
Model NO. Ladle refining furnace transformer
Rated capacity 20000kVA
Series Ladle refining furnace transformer
Product Detail

Description
The ladle refining furnace (LF furnace) transformer is a core equipment in the iron and steel smelting industry, primarily used to provide stable electric energy for the molten steel refining process. Its performance directly impacts the efficiency, energy consumption, and safety of steel production. With the development of electric furnace steelmaking technology, especially the popularization of large-scale LF furnaces above 40 tons, the design and technical standards of transformers have gradually shifted towards high efficiency and internationalization, forming a technological trend centered on energy conservation, reliability, and low maintenance.

Key Features

Energy Efficiency: Low no-load/load losses, optimized impedance voltage; uses Baowu/Nippon Steel 30Z130/30Q130 silicon steel. 

Reliability: 30+ year design life; fully oblique core joints, German Georg shear (<0.02mm burr), low-magnetic steel clamping. 

Overload Capability: Stable operation at 120% load via oxygen-free copper windings, small oil gaps, and cooling cylinder structures. Low Maintenance: 10+ years maintenance-free; vacuum oil injection, anti-aging seals, and folded plate tanks prevent leaks.

Components

Core

  • Material: Uses Baowu 30Z130 or Nippon Steel 30Q130 silicon steel, matching materials used in developed countries.

  • Structure: Full oblique-joint lamination design with low-magnetic steel plate pull rods for clamping, eliminating punching holes to ensure uniform magnetic flux density across core sections without distortion.

  • Processing: German Georg shearing line controls burrs ≤0.02mm (standard ≤0.05mm) and length tolerance ≤0.2mm/m, improving lamination factor to reduce local overheating, noise, and no-load losses.

Windings

  • Material: Oxygen-free copper magnet wires (P<0.017241 at 20°C) with precise insulation paper wrapping.

  • Design: Small oil gaps, internal/external oil baffles, and cooling cylinder structure enhance axial/radial stability, overload capacity, and reduce losses.

  • High-Voltage Solutions: "8"-type coils for one-time winding in high-load voltage regulation and 110kV-grade products, improving strength and reducing eddy current losses.

Body

  • Structure: Laminated wood for all wooden parts to enhance lead frame rigidity; upper/lower pressboards made of insulation boards or epoxy molded parts to increase conductor-to-ground insulation distance and reduce "window height" dimensions.

  • Insulation: Imported cardboard for main insulation, multi-coil integral assembly, and Norwegian steam drying equipment to ensure thorough drying without damaging insulation.

Oil Tank

  • Design: Folded plate structure minimizes welds, tested for positive/negative pressure to ensure sealing reliability.

  • Loss Reduction: Low-magnetic steel or magnetic shielding in strategic positions reduces additional losses from busbar magnetic fields on the tank wall, effectively preventing leakage and reducing losses.

Assembly

  • Process: Hydraulic compaction after body drying and vacuum oil injection to eliminate winding bubbles and reduce partial discharge.

  • Sealing: Anti-aging sealing materials address oil leakage; control circuits (gas relay, thermometers, etc.) integrated into a top-mounted junction box for a sleek, unified appearance.

Accessories

  • Cooling: YS1 water-coolers or stainless steel spiral plate coolers; anti-pollution high-voltage bushings increase creepage distance.

  • Tap Changers: Advanced "M" or "V" type from leading manufacturers with remote display and control interfaces.

  • Oil System: Karamay naphthenic anti-aging transformer oil in fully enclosed tanks with pressure relief valves and diaphragm conservators for complete protection.

Transformer Maintenance and Technical Assurance Summary

For transformer maintenance, long-distance transported core-hanging products require post-arrival checks to address loose fasteners and facilitate user acceptance, while routine overhauls should focus on replacing mechanical wear parts (e.g., pumps) per the original cycle. Quality assurance includes designing windings with a 20% overload margin (e.g., 24000kVA for a 20000kVA-rated LF furnace transformer) to ensure stable operation at 120% load, with impedance voltage ≤8% and heat load calculations based on the higher capacity. Anti-impact and short-circuit measures enhance coil axial/radial stability via high-voltage-grade wires, precise drying, hydraulic compaction, and multi-support structures. To guarantee 20-year maintenance-free operation, the design uses Karamay naphthenic oil in fully enclosed tanks with diaphragm conservators, anti-aging seals, and regular oil chromatographic analysis. Key improvements include Baowu/Nippon Steel silicon steel cores with ultra-low burr shearing, oxygen-free copper windings with small oil gaps, laminated wood bodies, folded-plate tanks with magnetic shielding, and integrated control systems. Future trends for ore-heating furnaces include single-phase transformers with side-mounted water-cooling for ≥15000kVA models, while maintenance prioritizes non-intrusive monitoring via oil analysis to reduce costs and contamination risks.

Know your supplier
Vziman
Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150000000
Professional Experience
3 years
Workplace
10000m²
占位
占位
Related Products
Related Knowledges
What are the development trends of voltage transformers?
What are the development trends of voltage transformers?
By Echo, 12 Years in the Electrical IndustryHi everyone, I'm Echo, and I've been working in the electrical industry for 12 years.From early involvement in commissioning and maintenance of distribution rooms to later participation in electrical system design and equipment selection for large-scale projects, I’ve witnessed how voltage transformers have evolved — from traditional analog devices to intelligent, digital components.The other day, a new colleague from a power company asked
Echo
07/02/2025
Design of Electromagnetic Compatibility Performance for Electronic Voltage Transformers
Design of Electromagnetic Compatibility Performance for Electronic Voltage Transformers
With the rapid development of power systems, electronic voltage transformers (EVTs), as key measurement devices in power systems, their performance stability and reliability are crucial for the safe and stable operation of power systems. The electromagnetic compatibility (EMC) performance, as one of the core indicators of EVTs, is directly related to the ability of the device to work normally in complex electromagnetic environments and whether it will cause electromagnetic interference to other
Dyson
07/02/2025
Case Analysis of Abnormal Secondary Circuits in Voltage Transformers
Case Analysis of Abnormal Secondary Circuits in Voltage Transformers
1. Fault SituationIn September 2023, as a front - line fault maintenance worker, I detected abnormal voltage on the 10kV Section I bus of a substation during monitoring duty and informed the operation and maintenance team. The monitoring system showed: U0 = 0 kV, Ua = 6.06 kV, Ub = 5.93 kV, Uc = 6.05 kV, Uab = 10.05 kV, Ubc = 5.94 kVMy team and I rushed to the site. We suspected the secondary air circuit breaker of the 10kV Section I bus voltage transformer was closed and found the U - phase fus
Felix Spark
07/02/2025
What are the causes of failure of ferromagnetic voltage transformers in new energy power stations?
What are the causes of failure of ferromagnetic voltage transformers in new energy power stations?
By Felix, 15 Years in the Electrical IndustryHi everyone, I'm Felix, and I've been working in the electrical industry for 15 years.From early involvement in traditional substation commissioning and maintenance to now managing electrical system operations for multiple photovoltaic and wind power projects, one of the most frequently encountered devices I deal with is the Electromagnetic Voltage Transformer (PT).The other day, a shift operator at a new energy plant asked me:“We have an electr
Felix Spark
07/02/2025
In which directions will dry-type transformers develop in the future?
In which directions will dry-type transformers develop in the future?
By Echo, 12 Years in the Electrical IndustryHi everyone, I'm Echo, and I've been working in the electrical industry for 12 years.From my early days doing commissioning and maintenance in distribution rooms, to later participating in electrical system design and equipment selection for large-scale projects, I’ve witnessed how dry-type transformers have evolved from traditional tools into smarter, greener devices.Recently, a new colleague asked me:“What’s the current state of dry
Echo
07/02/2025
Installation and Commissioning of 10kV Dry-Type Transformers
Installation and Commissioning of 10kV Dry-Type Transformers
By James, 10 Years of Electrical Equipment Maintenance ExperienceHi everyone, I’m James, and I’ve been working in electrical equipment fault repair for 10 years.Over the past decade, I’ve worked in factories, substations, and distribution rooms of all sizes, involved in the installation, commissioning, maintenance, and troubleshooting of dry-type transformers. Dry-type transformers are among the most common electrical devices we deal with on a daily basis.Today, a new colleague
James
07/01/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!