• 9.6kWh-143kWh Combined type-high voltage energy storage battery
  • 9.6kWh-143kWh Combined type-high voltage energy storage battery
  • 9.6kWh-143kWh Combined type-high voltage energy storage battery
9.6kWh-143kWh Combined type-high voltage energy storage battery
$38016.00
Model
DSH-30K
DSH-30K
DSH-25K
DSH-25K
DSH-20K
DSH-20K
DSH-15K
DSH-15K
DSH-10K
DSH-10K
DDH-143K
DDH-143K
DDH-120K
DDH-120K
DDH-107K
DDH-107K
DDH-80K
DDH-80K
DDH-68K
DDH-68K
DDH-54K
DDH-54K
DDH-40K
DDH-40K
DDH-27K
DDH-27K
DCH-75K
DCH-75K
DCH-50K
DCH-50K
DCH-45K
DCH-45K
DCH-40K
DCH-40K
DCH-30K
DCH-30K
DCH-25K
DCH-25K
DCH-20K
DCH-20K
DCH-15K
DCH-15K
DCH-10K
DCH-10K
Basic info
Brand POWERTECH
Model NO. Combined type-high voltage energy storage battery
Mounting type Stack mounting
Energy storage capacity 28.8kWh
Master-slave mode 1 host 6 slave
System architecture Overall-Master-Slave
Series Industrial&Commercial energy storage
Product Detail

Combined type-high voltage energy storage battery free combination

自由堆叠.png

Technical parameter

DCH series (Rack stack install)

image.png

DDH seriesCabinet drawer type install

image.png

DSH seriesgravity-stacked

image.png

Unified parameter description:

Secondary architecture: The BMU and BCU control the data monitoring, charge and discharge, and energy management of the energy storage system.

Three-tier architecture: The BMU controller, BCU controller, and BAU controller are responsible for hierarchical management of modules and PACK clusters, and communication and control of air conditioners and fire fighting devices.

Fire protection: Cabinet type high pressure energy storage adopts a two-level fire protection scheme. A single battery contains 12g aerosol monomer automatic fire extinguishing device, and 300g aerosol monomer automatic fire extinguishing device in the cabinet.

Cell: Square aluminum shell lithium iron phosphate battery

Screen: High voltage system optional display: secondary structure add 500RMB, tertiary structure add 1800 RMB.

Life: 6000 cycles of product A standard DOD 80%/25/0.5C.

Communication mode: RS485/RS232/CAN Communication options: Bluetooth/WiFi.

What is High Voltage Direct Current (HVDC) technology?

High Voltage Direct Current (HVDC) technology is a technology used for long-distance power transmission. It is characterized by using direct current instead of traditional alternating current (AC).

Working principle.

  • Rectification:At the sending end, alternating current (AC) is converted into direct current (DC) through a rectifier.The rectifier is usually based on a thyristor rectifier or other solid-state switching devices such as IGBT (Insulated Gate Bipolar Transistor).

  • Transmission:The converted direct current is transmitted through high-voltage direct current cables or lines.

  • Since direct current does not generate inductive reactance and capacitive reactance, it has lower losses and is suitable for long-distance transmission.

  • Inversion:At the receiving end, direct current is converted back into alternating current (AC) through an inverter.

        The inverter also uses thyristors or other solid-state switching devices.


Know your supplier
POWERTECH
We are an electrical company that manufactures and sells high and low voltage electrical products.
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$120000000
Professional Experience
7 years
Workplace
580000m²
占位
占位
Related Products
Related Knowledges
What are the causes of failure of ferromagnetic voltage transformers in new energy power stations?
What are the causes of failure of ferromagnetic voltage transformers in new energy power stations?
By Felix, 15 Years in the Electrical IndustryHi everyone, I'm Felix, and I've been working in the electrical industry for 15 years.From early involvement in traditional substation commissioning and maintenance to now managing electrical system operations for multiple photovoltaic and wind power projects, one of the most frequently encountered devices I deal with is the Electromagnetic Voltage Transformer (PT).The other day, a shift operator at a new energy plant asked me:“We have an electr
Felix Spark
07/02/2025
In which directions will dry-type transformers develop in the future?
In which directions will dry-type transformers develop in the future?
By Echo, 12 Years in the Electrical IndustryHi everyone, I'm Echo, and I've been working in the electrical industry for 12 years.From my early days doing commissioning and maintenance in distribution rooms, to later participating in electrical system design and equipment selection for large-scale projects, I’ve witnessed how dry-type transformers have evolved from traditional tools into smarter, greener devices.Recently, a new colleague asked me:“What’s the current state of dry
Echo
07/02/2025
Installation and Commissioning of 10kV Dry-Type Transformers
Installation and Commissioning of 10kV Dry-Type Transformers
By James, 10 Years of Electrical Equipment Maintenance ExperienceHi everyone, I’m James, and I’ve been working in electrical equipment fault repair for 10 years.Over the past decade, I’ve worked in factories, substations, and distribution rooms of all sizes, involved in the installation, commissioning, maintenance, and troubleshooting of dry-type transformers. Dry-type transformers are among the most common electrical devices we deal with on a daily basis.Today, a new colleague
James
07/01/2025
What are the reasons for low insulation at the low-voltage side of a dry-type transformer?
What are the reasons for low insulation at the low-voltage side of a dry-type transformer?
Hi everyone, I’m Felix, and I’ve been working in electrical equipment fault repair for 15 years.Over these years, I’ve traveled across factories, substations, and distribution rooms all over the country, troubleshooting and repairing all kinds of electrical equipment. Dry-type transformers are among the most common devices we deal with.Today, a friend asked me:“What does it mean when the low-voltage side of a dry-type transformer has low insulation resistance?”Great
Felix Spark
07/01/2025
What tests are required for dry-type transformers?
What tests are required for dry-type transformers?
1 Pre - commissioning InspectionAs a front - line tester, before formally commissioning a dry - type transformer, I need to carry out a comprehensive and systematic inspection. First, I conduct a visual inspection of the transformer body and its accessories, carefully checking for mechanical damage or deformation. Then, I check whether the leads of the high - and low - voltage windings are firmly connected and whether the bolt tightening torque meets the standard requirements (usually 40 - 60N&m
Oliver Watts
07/01/2025
What aspects need attention during the installation of dry-type transformers?
What aspects need attention during the installation of dry-type transformers?
1 Pre - installation PreparationAs a front - line installer, I know very well that the preparation work before installing a dry - type transformer must be thorough. First, I will carefully review the design drawings and technical documents, and check one by one the technical parameters such as the model specification, rated capacity, and voltage level of the transformer to ensure they are in full compliance with the design requirements. Then, I will conduct an unpacking inspection of the transfo
James
07/01/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!