• 12kV, 17.5kV, 24kV available to 36kV Indoor Vacuum Circuit Breaker
12kV, 17.5kV, 24kV available to 36kV Indoor Vacuum Circuit Breaker
discuss personally
Model
VSC-24/1600
VSC-24/1250
VSC-24/800
VSC-24/630
VSC-12/1600
VSC-12/1250
VSC-12/800
VSC-12/630
Basic info
Brand ROCKWILL
Model NO. 12kV, 17.5kV, 24kV available to 36kV Indoor Vacuum Circuit Breaker
Rated voltage 24kV
Rated normal current 1600A
Rated frequency 50/60Hz
Series VSC
Product Detail

Product Introduction

VSC medium-voltage indoor vacuum circuit breaker is applicable for three-phase AC power system of rated voltage up to 7.2kV~24kV and frequency 50/60HZ,widely used in many fields such as power plant, transformer substation, petrol chemical industry, metallurgy, manufacturing industry, airport, residential area, etc., to control and protect the electric equipment, especially, It is used for the occasion that needs infrequent operation at rated current or multi-breaking short circuit current, may be mounted in the indoor air insulating switchgear like type KYN28 or KYN96, ABB type ZS series, etc. This circuit breaker is standards as GB1984-2003 AC high voltage circuit breaker,JB3855 3.6-40.5Kv indoor AC High voltage circuit breaker,DL/T403 Specification of 12-40.5Kv indoor High voltage vacuum circuit breaker for order as well as IEC60694.

This circuit breaker is made with mature APG technology. The application of VSC terminal buffer guarantees the indoor terminal is ever more reliable in nay operation environment. VSC can fully meet the requirement of GB, DL, IEC, DIN, VDE as well as standards of other advanced industrial countries.

Service environment

  • Air temperature: Maximum temperature: +40℃; Minimum temperature:-25℃

  • Humidity: Monthly average humidity 95%; Daily average humidity 90% .

  • Altitude above sea level: Maximum installation altitude: 2500m

  • Ambient air not apparently polluted by corrosive and flammable gas, vapor etc.

  • No frequent violent shake

Main technical specifications

Note:For short circuit breaking current & rated current is optional by clients.

Structure & characteristic

1) Wiring board for income line secondary

2) Counter

3) Closing coil

4) Auxiliary switch 8NO,8NC is optional

5) Charging chain

6) Motor

Installation sizes& outline dimensions

 

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Documents
Public.
12kV, 17.5kV, 24kV available to 36kV Indoor Vacuum Circuit Breaker
Manual English
PDF
Related Products
Related Knowledges
What is the current application status and development trend of medium-voltage switchgear?
What is the current application status and development trend of medium-voltage switchgear?
With the accelerated automation of power equipment, various medium-voltage switchgear have emerged in the market. Classified by insulation media, they are mainly divided into air-insulated, SF₆ gas-insulated and solid-insulated types, each with its own advantages and disadvantages: solid insulation offers good performance but poor environmental friendliness, SF₆ features excellent arc extinguishing capability but is a greenhouse gas, and air insulation has high cost-performance but larger volume
Echo
06/11/2025
What components make up the design of medium-voltage ring network distribution switchgear?
What components make up the design of medium-voltage ring network distribution switchgear?
As an expert who has been deeply engaged in the field of power system design for many years, I have always paid attention to the technological evolution and application practice of medium-voltage ring main distribution equipment. As a core electrical device in the secondary distribution link of the power system, the design and performance of such equipment are directly related to the safe and stable operation of the power supply network. The following is a professional analysis of the key design
Dyson
06/11/2025
What aspects should be paid attention to when installing medium-voltage switch cabinets during the initial stage of subway operation?
What aspects should be paid attention to when installing medium-voltage switch cabinets during the initial stage of subway operation?
1. Statistics on Common Faults of Medium-Voltage Switchgear in the Early Operation StageAs project participants, we found during the early operation of a new metro line: 21 sets of power supply equipment were put into use, with a total of 266 accident phenomena in the first year. Among them, 77 faults occurred in medium-voltage switchgear, accounting for 28.9%—significantly higher than faults in other equipment. Statistical analysis shows that major fault types include: protection device s
Felix Spark
06/11/2025
Practice of Intelligent Switchgear Transformation in the 6kV Working Section of a Power Plant
Practice of Intelligent Switchgear Transformation in the 6kV Working Section of a Power Plant
Due to the long service life and severe aging of the equipment, the switches in the 6kV working section of Unit 6 of a certain power plant have potential safety hazards such as deformed locating pins, abnormal closing positions of the earthing switches, and malfunctions of the protection devices. These hazards have threatened the stable operation of the unit, making the transformation extremely urgent. Meanwhile, considering the recent cases of electric shock casualties involving medium-voltage
Echo
06/11/2025
Analysis of the Safety and Reliability Assurance of Medium-Voltage Switchgear
Analysis of the Safety and Reliability Assurance of Medium-Voltage Switchgear
As a professional engaged in power system operations, I recognize that medium-voltage (MV) switchgear plays a pivotal role in power distribution, metering, and protection. Ensuring its operational safety and reliability is critical—any malfunction can severely disrupt the entire power system. To enhance reliability, we must prioritize design-level optimizations, enabling MV switchgear to fulfill its functions and safeguard grid stability.1. Definition of Medium-Voltage SwitchgearIn my prac
Felix Spark
06/10/2025
What should be noted when using indoor vacuum circuit breakers?
What should be noted when using indoor vacuum circuit breakers?
I. Overvoltage PreventionVacuum circuit breakers excel in interrupting performance, but high overvoltage may occur across inductors during the switching of inductive loads due to abrupt changes in loop current, which requires special attention. When switching small-capacity motors, starting currents are large, so measures like step-down starting should be adopted to limit the current.Transformers with different structures show distinct characteristics: oil-immersed transformers have high impulse
Echo
06/10/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放