• 252kV HV SF6 circuit breaker
  • 252kV HV SF6 circuit breaker
252kV HV SF6 circuit breaker
discuss personally
Model
LW58-252(W)/T5000-63
LW58-252(W)/T4000-50
Basic info
Brand Wone
Model NO. 252kV HV Gas circuit breaker
Rated voltage 252kV
Rated normal current 5000A
Rated frequency 50/60Hz
Rated short circuit breaking current 63kA
Series LW58-252
Product Detail

Product introduction:

LW58-252(W) outdoor self-energy power high voltage SF6 circuit breaker is suitable for the electric power system of AC 50Hz and 252kV, which is the control and protection equipment for the electric power system, as well as for circuit breaker connection.

The product uses SF6 gas as the arc extinguishing and insulation medium, adopting the self-energy power arc extin­guishing double-action-type interrupter structure technique, equipped with new-type spring operating mechanism., with features of strong switching ability, less operating power, bow noise and high reliability, the technical indicators have reached similar products in domestic and international advanced level.

Three-phase SF6 circuit breaker, which is operated by one mechanism for one pole, is changed to three-phase mechanical linkage circuit breaker which is operated by one mechanism. The decrease of mechanism improves the linkage reliability for three-phase SF6 circuit breaker to avoid lack of phase operation.

Main characteristic:

  •  Adopting the self- energy power arc extinguishing and double-action-type structure technique breaking capacity is more stabilization.

  •  This product has less, operating power, high reliability and mechanical Life cycle up to 10,000 times;

  •  Dynamic and fixed contact using copper tungsten arc overall sintered structure, withstand high temperature, under the arc burning in a small, full breaking capacity of more than 20 times;

  •  Reliable sealing performance: it is guaranteed that the SF6 gas has an annual leakage of far less than 0.5 percent;

  •  Strict dehumidification process for component parts of the product the SF6, moisture content ls far lower than similar products;

  • The circuit breaker has high insulation level and the creepage distance is more than 31mm/Kv;

  • The valve plate of the arc extinguishing compartment is made of new-type light weight Zinc-base alloy, Compared with the traditional materials adopted for similar products, this, material has more stable and reliable, gas feature and breaking performance;

  •  The spout made of import PTFE mixed with other micro-co.ponents.t has stable breaking performance and strong ablation resistance;

  • Electrical units ln secondary circuit and SF, density relay are high-quality impact or Joint-venture products:

  • Pure spring operating mechanism the important component parts in the mechanism are forged with quality alloy steel for high strength and abrasion resistant, which can ensure low fault rate under frequent operation of the breaker.

Main technical parameters:

1732504456227.png

Instructions on placing orders  : 

  • Model and format of the circuit breaker;

  • Rated electrical parameters (voltage, current, breaking current, etc);

  • Working conditions for using (environment temperature, altitude, and environment pollution level);

  • Rated control circuit electrical parameters (Rated voltage of energy-store moter and Rated voltage of opening, closing coil);

  • Names and quantities of spare items needed, parts and special equipment and tools (to be otherwise ordered);

  • The wire connecting direction of the primary upper terminal.

What are the main types of tank circuit breakers?

SF6 Gas-Insulated Circuit Breaker:

  • SF6 Gas-Insulated Circuit Breaker: Uses sulfur hexafluoride (SF6) gas as the insulating and arc-quenching medium. SF6 gas has excellent insulating properties and arc-quenching capabilities, allowing it to meet the high voltage and high current breaking and insulation requirements in a small space. It is widely used in high-voltage and ultra-high-voltage power systems.

Oil-Immersed Circuit Breaker:

  • Oil-Immersed Circuit Breaker: Uses insulating oil as the insulating and arc-quenching medium. Insulating oil has good insulating properties and heat dissipation capabilities, effectively extinguishing arcs and cooling the contacts. However, due to the fire risk and environmental pollution associated with insulating oil, its application range has gradually decreased. Currently, it is mainly used in specific situations where fire prevention requirements are not stringent.


Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Analysis of the Safety and Reliability Assurance of Medium-Voltage Switchgear
Analysis of the Safety and Reliability Assurance of Medium-Voltage Switchgear
As a professional engaged in power system operations, I recognize that medium-voltage (MV) switchgear plays a pivotal role in power distribution, metering, and protection. Ensuring its operational safety and reliability is critical—any malfunction can severely disrupt the entire power system. To enhance reliability, we must prioritize design-level optimizations, enabling MV switchgear to fulfill its functions and safeguard grid stability.1. Definition of Medium-Voltage SwitchgearIn my prac
Felix Spark
06/10/2025
What should be noted when using indoor vacuum circuit breakers?
What should be noted when using indoor vacuum circuit breakers?
I. Overvoltage PreventionVacuum circuit breakers excel in interrupting performance, but high overvoltage may occur across inductors during the switching of inductive loads due to abrupt changes in loop current, which requires special attention. When switching small-capacity motors, starting currents are large, so measures like step-down starting should be adopted to limit the current.Transformers with different structures show distinct characteristics: oil-immersed transformers have high impulse
Echo
06/10/2025
The application of indoor high-voltage vacuum circuit breakers
The application of indoor high-voltage vacuum circuit breakers
In the first half of 2007, as project participants from the Electromechanical Equipment Company of Huaibei Mining Group, we carried out a technical transformation of the 10kV substation in the East Factory Area. Our primary task was to replace the original 10kV disconnector - oil - immersed circuit breaker units with ZN20 indoor high - voltage vacuum circuit breakers.Previously, the SN10 - 10 oil - immersed circuit breakers had been in operation for an extended period, leading to severe oil leak
Echo
06/09/2025
What are the common faults and corresponding solutions for indoor drawer-type high-voltage vacuum circuit breakers?
What are the common faults and corresponding solutions for indoor drawer-type high-voltage vacuum circuit breakers?
Inability to Push In or Withdraw the Draw-out CarriageThe main manifestation is difficulty in inserting the carriage, which may cause equipment damage and threaten production when severe. The causes and countermeasures are shown in Table 1.The circuit - breaker fails to close. It manifests as the closing core actuating but the circuit - breaker not closing successfully; or the closing core not actuating, which shows that the control circuit of the circuit - breaker is open - circuited or the mec
Felix Spark
06/09/2025
What are the common faults and handling methods of the operating mechanisms of 35kV and 10kV indoor vacuum circuit breakers?
What are the common faults and handling methods of the operating mechanisms of 35kV and 10kV indoor vacuum circuit breakers?
In power system operation and maintenance, we have found that 35kV and 10kV indoor vacuum circuit breakers, as core primary equipment of high-voltage switchgear, are widely used in main grid and user substations due to their high reliability and low maintenance workload. From daily inspections and live detection to routine maintenance, vacuum circuit breakers always remain our key focus, as their operational quality is directly related to the stability and reliability of the power system. This p
Felix Spark
06/09/2025
Analysis of the Impact of Vacuum Arc Chamber Inspection and Maintenance on Improving the Reliability of Vacuum Circuit Breakers
Analysis of the Impact of Vacuum Arc Chamber Inspection and Maintenance on Improving the Reliability of Vacuum Circuit Breakers
Vacuum circuit breakers are widely used in distribution networks. As core components of power supply equipment, their performance hinges on both vacuum interrupters’ capabilities and circuit breakers’ mechanical characteristics (contact opening distance, stroke, pressure, average closing/opening speed, closing bounce time, opening - closing asynchronism, operation times, and cumulative allowable wear of contacts). Both are critical for reliable operation. The vacuum interrupter is th
Oliver Watts
06/09/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放