• 100kVA Step Up All Copper Three Phase Dry Type Distribution Transformer
  • 100kVA Step Up All Copper Three Phase Dry Type Distribution Transformer
100kVA Step Up All Copper Three Phase Dry Type Distribution Transformer
discuss personally
Model
SC(B)-35KV-100KVA
SC(B-20KV-100KVA
SC(B)-10KV-100KVA
Basic info
Brand Vziman
Model NO. 100KVA Step Up All Copper Three Phase Dry Type Distribution Transformer
Rated capacity 100kVA
Voltage grade 10KV
Series SC(B)
Product Detail

Description:

  • Dry-type transformers rely on natural or forced air cooling to dissipate the heat generated during operation. Proper ventilation and airflow around the transformer are essential to prevent overheating and maintain optimal efficiency.

  • Dry-type transformers are less susceptible to environmental factors than oil-immersed transformers, but certain environmental conditions still need to be taken into account.

  • The installation site should have protection against exposure to moisture, dust, corrosive agents, or other contaminants that could potentially degrade the transformer's insulation and components.

  • In harsh environments, such as coastal areas or industrial settings, additional protection measures, such as weatherproof enclosures or specialized coatings, may be necessary.

  • Proper electrical connections, including the primary and secondary windings, as well as the grounding of the transformer, must be carried out according to relevant electrical codes and manufacturer's specifications.

Feature:


  • The magnetic core has a miter step joint to ensure optimum performance and minimum sound levels by using step lap technology.

  • Windings are cast under vacuum with epoxy resin. Transient analysis tests have been performed to verify the electrical stress distribution.

  • Air-cooling system adopts top-blowing cross flow fan, which has the characteristics of low noise, high wind pressure, beautiful look, etc.

  • Intelligent temperature controller improves the safety and reliability of the transformer.

  • Supply various Enclosure options in IP20, IP23, etc.


Parameter:

image.png

Installation Location:


  • Installed in places without fire, explosion hazard, serious pollution, chemical corrosion and cluster vibration, indoor or outdoor.

  • Supply Ability:500 Set/Sets per Month.

Customized Service:

  • E2 Environmental Class.

  • C2 Climate Class.

  • F1 Fire Resistance Class.

Product Advantages:

  •  Vacuum-Casting

  • Our product is manufactured with vacuum casting process using a metal pattern, producing a thick resin layer with a smooth surface.

  •  Partial Discharge Free

  • Lower partial discharge characteristics.

  • All units are subjected to partial discharge test.

  • Voltage that is twice that of the operating system is applied to ensure safety.

  • Partial discharge is less than 10 pC.

  •  Shop Test Items.

Routine test:

  • Routine test is a must test for all transformers in our workshop.

  • Type test (as requested).

  • Lightning impulse test.

  • Temperature-rise test.

  • Measurement of sound level.


What is a step-up all-copper three-phase dry-type distribution transformer?

Definitions and Characteristics:

  • Voltage Boosting: It means that a transformer converts the input low-voltage electrical energy into high-voltage electrical energy.

  • All-Copper: The windings of the transformer are all made of copper wires, which possess excellent electrical conductivity and mechanical strength.

  • Three-Phase: It indicates that the transformer has three independent windings and is applicable to three-phase alternating current systems.

  • Dry-Type: It means that the transformer does not use a liquid cooling medium (such as transformer oil), and usually adopts natural air cooling or forced air cooling.

Working Principle:

  • Input Voltage: The low-voltage power source is applied to the transformer through the primary winding.

  • Generating Magnetic Field: The current in the primary winding generates an alternating magnetic field in the iron core.

  • Transferring Magnetic Field: The alternating magnetic field is transferred to the secondary winding through the iron core.

  • Inducing Electromotive Force: The alternating magnetic field induces an electromotive force in the secondary winding, generating a high-voltage output voltage.

  • Output Voltage: The secondary winding outputs the required high-voltage electrical energy for the load to use.


Know your supplier
Vziman
Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150000000
Professional Experience
3 years
Workplace
10000m²
占位
占位
Related Products
Related Knowledges
What are the common failures in single-phase distribution transformers?
What are the common failures in single-phase distribution transformers?
Single - phase distribution transformers, as crucial voltage transformation and power distribution equipment in the power system, are widely used in rural power grids, low - voltage residential areas, and areas with concentrated single - phase loads.With the continuous increase in the proportion of single - phase loads in the distribution network, the failure rate of single - phase transformers has also increased. Timely identification and handling of these faults are of great significance for e
Felix Spark
06/18/2025
Comprehensive Analysis of Single-Phase Distribution Transformer Technologies in Multiple Application Scenarios
Comprehensive Analysis of Single-Phase Distribution Transformer Technologies in Multiple Application Scenarios
Introduce the 10 kV line to the load center. Following “small capacity, dense points, short radius”, adopt the new single - phase distribution mode, featuring notable low - voltage line loss reduction, high power quality, and reliability. By comparing the economy and reliability of single - phase vs three - phase transformers in different scenarios, this paper analyzes their applicable scope and application suggestions.Single - phase transformers are classified by distribution mode:
Echo
06/18/2025
What are the technical features and applications of single-phase distribution transformers?
What are the technical features and applications of single-phase distribution transformers?
1 Technical Features of Single - phase TransformersFrom the operation practice of foreign distribution networks, it is known that single - phase transformers are quite widely applied. Compared with three - phase transformers, they have unique advantages, which are specifically reflected as follows:1.1 Simple StructureThis characteristic makes that, when using the same materials, for single - phase transformers with the same capacity, their no - load losses are lower than those of three - phase t
Echo
06/17/2025
Application Analysis of High-Voltage Single-Phase Distribution Transformers in Power Distribution Networks
Application Analysis of High-Voltage Single-Phase Distribution Transformers in Power Distribution Networks
1. Safety Hazards in Substation Operation1.1Transformer FailuresTransformers are critical substation equipment and maintenance focal points. Loose/defective components often cause malfunctions, while internal damage (e.g., oil tank impurities/water/bubbles) triggers partial discharge, risking major losses during outages.1.2 Overvoltage RisksOutdoor overvoltage threatens equipment. Lightning-induced impulse currents alter transformer electromagnetic energy, and circuit breaker misoperations cause
Echo
06/17/2025
Prototype Development of 20 kV Single-Phase Distribution Transformer
Prototype Development of 20 kV Single-Phase Distribution Transformer
1. Design of 20 kV Single - phase Distribution Transformer20 kV distribution systems usually adopt cable lines or mixed cable - overhead line networks, and the neutral point is mostly grounded through a small resistance. When a single - phase grounding occurs, there will be no problem that the phase voltage will rise by more than √3 times as in the case of a single - phase fault in a 10 kV system. Therefore, the single - phase distribution transformer of the 20 kV system can adopt the type
Dyson
06/17/2025
Single-Phase Transformer with High Lightning Impulse Withstand Capability
Single-Phase Transformer with High Lightning Impulse Withstand Capability
1 IntroductionTo ensure the safe operation of railways and reduce the risk of lightning damage to railway telecommunication control systems, the author has specially researched and designed a single - phase series transformer with a relatively high impulse voltage withstand level, with the model number D10 - 1.2 - 30/10. This transformer is equipped with an oil conservator and adopts a fully sealed structure (it can also be designed as a dry - type structure according to actual needs). This seri
Dyson
06/17/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放