• 0.7-3kW 1 MPPT Single Phase Residential Grid-tied Inverters
  • 0.7-3kW 1 MPPT Single Phase Residential Grid-tied Inverters
0.7-3kW 1 MPPT Single Phase Residential Grid-tied Inverters
discuss personally
Model
WN3000-XS-11
WN2000-XS-11
Basic info
Brand Wone
Model NO. 0.7-3kW 1 MPPT Single Phase Residential Grid-tied Inverters
weight 5.8Kg
Max.Input Voltage 500V
Max. Input Current per MPPT 15A
Number of MPP trackers 1
Nominal Output Voltage 220/230V
Series Residential Grid-tied Inverters
Product Detail

Description:

GoodWe XS PLUS+ is an ultra-small residential solar inverter specifically designed to bring comfort and quiet operation as well as high efficiency to households. Its capacity ranges from 0.7kW to 3.0kW and its most outstanding characteristic is lightweight, which is only 5.8kg and as well as its extremely compact size equivalent to an A4 paper, that make it particularly easy to carry & install. Remarkably, it offers 130% of DC input oversizing and 110% of AC output overloading, and it's able to achieve maximum European efficiency of 97.2% for maximum performance. Conveniently, the communication options available on this inverter are both LAN and WiFi for smart home integration.

Feature:

Smart Control & Monitoring:

  •  Load consumption monitoring 

  • Power export limit

High Power Generation:

  •  Max. 15A DC input current per string

  • 40V start-up voltage

Superb Safety & Reliability:

  •  IP65 ingress protection 

  • Quality and robust components

Friendly & Thoughtful Design:

  • Fanless design for quiet operation 

  • A4 size with light weight

System Parameters:

image.png

image.png

What is MPPT?

Definition:
MPPT (Maximum Power Point Tracking) is an algorithm and technology used to adjust the output voltage and current of a power supply system (such as solar photovoltaic panels, wind turbines, etc.) in real - time so that it always operates at the maximum power point (Maximum Power Point, MPP), thereby maximizing the acquisition and utilization of renewable energy.

Working Principle

MPPT in photovoltaic systems:

  • Output characteristics of photovoltaic cells: The output power of photovoltaic cells changes with changes in light intensity and temperature. Its output characteristics are represented by a curve.

  • Maximum power point (MPP): Under different light intensity and temperature conditions, there is a point on the output characteristic curve of photovoltaic cells where the output power is the largest, that is, the maximum power point.

  • MPPT algorithm: By detecting the output voltage and current of photovoltaic cells in real time, calculate the current optimal operating point, and by adjusting the parameters of the inverter or charge controller, make the system always work near the maximum power point.

MPPT in wind power generation systems:

  • Output characteristics of wind turbines: The output power of wind turbines depends on wind speed and generator speed.

  • Maximum power point (MPP): Under different wind speed conditions, there is a point on the output characteristic curve of wind turbines where the output power is the largest.

  • MPPT algorithm: By adjusting the blade angle or generator speed of wind turbines, make the system always work near the maximum power point.


Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Method for Automatic Isolation of Customer Equipment Faults by Load Switches in Distribution Networks
Method for Automatic Isolation of Customer Equipment Faults by Load Switches in Distribution Networks
1 OverviewDistribution network safety has long been under - addressed, with its automation lagging substation automation . Using 10 kV intervals of existing substations to set line section points meets future grid needs . Configuration of distribution switches, section switches, and protection must match substation outgoing - line protection for reliability. Fault isolation, self - healing, and restoration are key to distribution automation .Scholars have studied smart distribution network fault
Felix Spark
06/30/2025
A Novel Detection Method for Stuck Faults in Load Switches
A Novel Detection Method for Stuck Faults in Load Switches
In recent years, as distribution automation advances, load switches see wider use in distribution lines. Yet, mechanical - failure - induced accidents are on the rise, burdening line operation and maintenance.Poor mechanical performance is the main cause of switch faults. Many scholars study large - scale switchgear operation, using methods like coil current detection, vibration signal analysis, switch travel testing, ultrasonic flaw detection, and infrared thermometry. Motor - current - based s
Oliver Watts
06/30/2025
What You Need to Know About Load Switch Malfunctions
What You Need to Know About Load Switch Malfunctions
Hey there, I’m Blue — been working as an electrical engineer for more than 20 years now.I’ve spent most of my career designing circuit breakers, managing transformers, and helping power companies solve all sorts of electrical system challenges.Today, a friend from Southeast Asia asked me:"What are the common faults of load switches?"Great question! So let’s break it down in simple terms — no fancy jargon, just real-world stuff you might actually see on the job or during maintenance.First, What E
Master Electrician
06/30/2025
What tests need to be conducted for load switches?
What tests need to be conducted for load switches?
As a technician with years of on-site experience in power testing, I understand the importance and complexity of load switch testing. Below, I combine practical work experience to elaborate on the full process of load switch testing, from testing items and methods to equipment and procedural specifications.I. Routine Electrical Performance Testing(1) Loop Resistance TestLoop resistance is a core indicator for evaluating a load switch's conductivity. I strictly follow GB/T 3804 and GB 1984 standa
Oliver Watts
06/28/2025
What are the common faults of load switches?
What are the common faults of load switches?
As an on-site maintenance technician, I frequently deal with electrical, mechanical, and insulation faults in load switches. The following outlines fault manifestations, causes, and solutions:I. Electrical Fault Handling(1) Contact HeatingContact heating is mainly caused by poor contact, insufficient pressure, or three-phase asynchrony. When the contact resistance exceeds 1.5 times the initial value, the temperature rise will exceed the standard in a 40℃ environment. For example, the FW4-10 swit
Felix Spark
06/28/2025
Short-Circuit Fault Analysis of 10kV Puffer-Type Load Switch
Short-Circuit Fault Analysis of 10kV Puffer-Type Load Switch
1. Fault OverviewIn June 2013, a fault occurred in a high - voltage switchgear in operation in a certain urban area, causing a 10kV line to trip. On - site investigation revealed that the faulty switchgear was a pneumatic ring - network high - voltage load switchgear (HXGN2 - 10 type), and the fault characteristic was athree - phase arc short circuit. After isolating the fault and restoring power supply to users, it should be noted that the same type of switchgear in this area, which was put int
Felix Spark
06/28/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!