Digital solutions

Distributed DTU Easergy T300
- Comprehensive features and flexbile scalability
- Tailored to meet future operational challenges of
distribution network automation
- Applications range from monitoring rooms to
medium and low voltage distribution stations
TH110-R cable joint temperature measurement
- Wireless passive, easy to install
- Direct measurement of conductor temperature
with high accuracy
PD110 series local discharge test device
- Real-time monitoring of equipment corona and
partial discharge status and change trend
VT/LPVT Lowpower voltage transformer
- High accuracy to meet protection and
measurement requiements
- No ferromagnetic resonance, no risk of second
short circuit
- Compact and esay to install, convenient and
reliable
CT/LVCT Bushing CT
- High accuracy to meet protection and
measurement requirements
- Highly integrated intelligent solutions
Intelligent power distribution status
monitoring unit
Backup power Management
Backup power management (UPS or batteries ) is widely used in industrial and
commercial buildings. However, they are often the weak link in the power supply
and can have serious consequences if they do not work properly.
In view of the harsher operating environment of substations, the RM6 SeT system
includes PS100 or PS50, specially designed for high insulation levels, to provide a
reliable backup power supply for smart devices 24 hours a day.
Easy maintenance:
- Single battery replacement option only
- Battery life alarms are sent over Modbus communication

Easergy T300
- Distributed modular intelligent power distribution terminal
- Support common communication protocols: IEC 60870-101/104, MODBUS,
IEC61850
- Medium and low voltage integration, medium voltage monitoring, transformer
temperature monitoring and outlet load monitoring
- PLC framework IEC61131-3 automation function customization
- Compatible with computer, mobile phone, mobile terminal and other mobile
operation and maintenance

Easergy monitors wireless sensors online
Medium voltage switch cable connection point is one of the key points in
the substation, loose and incorrect cable connection will lead to increased
impedance causing heat escape and eventually lead to cable connection failure.
Easergy TH110/ TH110-R provides continuous temperature monitoring for critical
power connections of medium voltage switches as a new generation of wireless
smart sensors:
- Prevent unplanned power outages
- Improve the safe operating environment for operations personnel and
equipment
- Predictive information to optimize operations processes

Easergy CL110 wireless environmental monitoring sensor
Long term battery powered, ZigBee low power wireless transmission, both
temperature and humidity monitoring
- ±1°C accuracy range temperature monitoring(-25°C to 90°C)
- 2% accuracy range relative humidity

Partial Discharge (PD) Online Monitoring
PD110 series office discharge monitoring device can monitor and report all kinds
of office discharge status and change trend in electrical equipment in real time,
and support qualitative and quantitative analysis of equipment office discharge
signal through discharge graph
- Collect the local discharge signal directly and calculate the local discharge
appatent charge pC value quantitatively
- According to the office release characteristic map, the type of office release
can be identified
- Measuring range 0-30000pC

Substation Intelligent Monitoring Terminal
(SMD)
- Monitor substation operating status and alarm of unexpected events. SMD
intelligent monitoring terminal helps you control the status and alarm events of
medium
- Intelligent fault handling suggestions