Description

WDYZ-201 Zinc oxide arrester live tester is a special instrument for testing the electrical performance of zinc oxide arresters. 

This instrument is suitable for live or power failure detection of zinc oxide arresters of various voltage levels. Dangerous defects such as aging.

The instrument is simple to operate and easy to use. The whole measurement process is controlled by the man-machine interface. 

It can measure the full current, resistive current and its harmonics, power frequency reference voltage and its harmonics, active power and phase difference of zinc oxide arresters. 

Large screen Real waveforms of voltage and current can be displayed.

 The instrument uses digital waveform analysis technology, adopts software anti-interference methods such as harmonic analysis and digital filtering to make the measurement results accurate and stable, and can accurately analyze the content of the fundamental wave and the 3rd to 9th harmonics.

Specifications

  • Power supply: internal lithium battery power supply or DC8.4V adapter

  •  Measuring range:

Leakage current: 0-20mA (expandable);

(Optional: Current clamp sensor 0-20mA.)

Voltage: 30-250V (expandable);

(Optional: Electric field strength input range: 30kV/m~300kV/m.)

Angle: 0-306º

Resistive current: 0-20mA (expandable);

Capacitive current: 0-20mA (expandable);

  •  Measurement accuracy:

Current: When the full current is >100μA: ±5% reading ±1 word;

Voltage: When the reference voltage signal is >30V: ±5% reading ±1 word.

  •  Measurement parameters:

Leakage current: full current waveform, fundamental RMS value, peak value.

Leakage Current Resistive Component: Waveform

1, 3, 5, 7, 9 valid values.

Positive peak Ir+ Negative peak Ir-.

Capacitive current fundamental.

Voltage: voltage waveform, voltage RMS.

Phase angle difference, power consumption.

  • Lithium battery parameters:

 Charging time > 2.5 hours

Continuous working time > 7 hours

Intermittent working time > 7×24 hours

  • FCL size: host 42cm×34cm×18cm

  •  The weight of the whole box: 7.0kg for the host





Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Modular Intelligent Substation - Prefabricated Secondary Switchgear Integration Assembly
Modular Intelligent Substation - Prefabricated Secondary Switchgear Integration Assembly
With the development of the national economy and society, the requirements for the quality and craftsmanship of power grid projects have become increasingly stringent. The need to improve the construction progress and quality of substations has created opportunities for the promotion of prefabricated cabin - type intelligent substations. The traditional on - site wiring and commissioning of secondary substation equipment involve a large amount of work. Moreover, on - site construction has to wai
Echo
06/13/2025
Application of Pre-integrated Prefabricated Substations in Renewable Energy Sector
Application of Pre-integrated Prefabricated Substations in Renewable Energy Sector
Against the backdrop of profound changes in the global energy landscape and the booming development of the new energy industry, the construction mode of traditional substations struggles to meet the rapid deployment needs of new energy projects. The modular intelligent prefabricated cabin substation, leveraging its innovative advantages, has become a key direction for optimizing the new energy power system. In - depth exploration of its technical principles, industry adaptability, and applicatio
Echo
06/13/2025
Research on Reliability Enhancement Scheme Implementation for Modular Intelligent Prefabricated Substations
Research on Reliability Enhancement Scheme Implementation for Modular Intelligent Prefabricated Substations
1 Implementation Strategies for the Scheme1.1 Deepen Survey and ResearchBefore constructing prefabricated cabin - type substations, it is necessary to conduct detailed surveys of local working conditions, clarify the construction scale and objectives, evaluate existing power facilities, plan projects, make up for infrastructure shortcomings, and adjust the construction rhythm. Meanwhile, control costs to avoid project suspension.1.2 Strengthen Structural ConstructionDuring promotion, multi - dim
Echo
06/13/2025
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
The secondary equipment area of conventional substations uses reinforced concrete or prefabricated steel structures, facing issues like long construction cycles, unreasonable functional zone design, strict environmental assessments, dust, noise, and disturbances. Primary and secondary equipment can only be installed after civil works and decoration, lowering construction efficiency.Prefabricated cabin substations integrate modularity, intelligence, and cost - effectiveness, boasting green, energ
Dyson
06/13/2025
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Under global climate diversity, alpine power construction faces technical and environmental challenges. Extreme climates, complex geology, and long - term low winter temperatures, along with ice, snow, and storms, strain electrical equipment stability and power facility construction (schedule, cost, maintenance). Traditional on - site substations, with long construction and poor adaptability, can’t meet alpine regions’ fast, stable power needs.Prefabricated cabin substations, as modu
Echo
06/13/2025
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Compact substation boxes, with advantages like safe operation, high reliability, and easy maintenance, are used in urban grid construction/renovation. Structurally divided into American - style (high - cost, noisy, low - efficiency, gradually phased out) and European - style (large - sized but more advantages, still popular).To address their pros/cons, ring - network prefabricated ones were developed.I. Basic Materials for Prefabricated Compact Substation BoxesMaterials need hardness, strength,
Echo
06/13/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放