• Single-phase fee-controlled smart watt-hour meter DDZY71-Z
Single-phase fee-controlled smart watt-hour meter DDZY71-Z
$66.00
Model
SEM-220
Basic info
Brand POWERTECH
Model NO. Single-phase fee-controlled smart watt-hour meter DDZY71-Z
Rated voltage 220V
Rated frequency 50(Hz)
Series DDZY71-Z
Product Detail

Description

DDZY71-Z/DDZY71-J series single-phase fee-controlled smart energy meter is used to measure AC single-phase active energy with a rated frequency of 50Hz. 

The product adopts national standards and industry standards such as GB/T 17215.321-2021 "Special Requirements for Electrical Measuring Equipment Part 21: Static Active Energy Meters (Class A, B, C, D and E)" and GB/T 15284-2002 "Special Requirements for Multi-rate Energy Meters" and 2020 Standard "Technical Specifications for Single-phase Smart Energy Meters". 

The communication protocol complies with the DL/T698.45 standard.

Industry applications

It is used to measure the consumption of electrical energy and is generally widely used in household and industrial electricity consumption.

Features

  • It adopts a special metering chip with high quality, high precision, high sensitivity, high stability, wide range and low power consumption.

  • The voltage sampling loop adopts the resistor voltage divider method.

  • The current sampling loop adopts high-quality, high-precision, high-stability, wide-range manganese-copper shunt or transformer.

  • The display adopts an LCD display with wide viewing angle, high contrast, UV protection, and reliable performance.

  • Application of digital processing technology and SMT process.

  • The structure is firm, flame retardant, anti-aging, and has good sealing performance. The structure of the case is unified and simple, beautiful and exquisite, and easy to install.

Technical parameters

The way the electric energy meter is connected to the line

Standard reference frequency

Accuracy rating

Voltage (V) Unom

Current (Ah) Imin Itel (Imax)

Direct

50Hz

Active grade A

220 0.25-0.5(60)
220 0.5-1(100)

Product show

企业微信截图_17155823784398.png


Know your supplier
POWERTECH
We are an electrical company that manufactures and sells high and low voltage electrical products.
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$120000000
Professional Experience
7 years
Workplace
580000m²
占位
占位
Related Knowledges
Failure Analysis and Design Optimization of Conventional Grounding Transformers
Failure Analysis and Design Optimization of Conventional Grounding Transformers
I. Core Cause of Damage: Electrodynamic Impact (Complying with GB/T 1094.5 / IEC 60076-5)The direct cause of high-voltage winding end collapse is the instantaneous electrodynamic impact induced by short-circuit current. When a single-phase grounding fault occurs in the system (such as lightning overvoltage, insulation breakdown, etc.), the grounding transformer, as the fault current path, withstands high-amplitude and steep-rise-rate short-circuit currents. According to Ampère's force law
Felix Spark
06/12/2025
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
1 Theoretical AnalysisIn distribution networks, grounding transformers serve two key roles: powering low - voltage loads and connecting arc - suppression coils at neutrals for grounding protection. Grounding faults, the most common distribution network fault, heavily impact transformers’ operating characteristics, causing sharp changes in electromagnetic parameters and status.To study transformers’ dynamic behaviors under single - phase grounding faults, build this model: Assume a tr
Felix Spark
06/12/2025
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
1 Classification of Neutral Grounding Methods for Solar Photovoltaic Power StationsInfluenced by differences in voltage levels and grid structures across regions, the neutral grounding methods of power systems are mainly categorized into non-effective grounding and effective grounding. Non-effective grounding includes neutral grounding via arc suppression coils and neutral ungrounded systems, while effective grounding comprises neutral solid grounding and neutral grounding via resistors. The sel
Dyson
06/12/2025
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
In a neutral-insulated three-phase power system, an earthing transformer provides an artificial neutral point, which can be solidly earthed or earthed via reactors/arc suppression coils. The ZNyn11 connection is typical, where zero-sequence magnetomotive forces in the inner/outer half-windings of the same core column cancel out, balancing fault currents in series windings and minimizing zero-sequence leakage flux/impedance.Zero-sequence impedance is critical: it determines fault current magnitud
Dyson
06/12/2025
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
The neutral grounding mode refers to the connection between the power system neutral point and ground. In China's 35 kV and below systems, common methods include ungrounded neutral, arc-suppression coil grounding, and small-resistance grounding. The ungrounded mode is widely used as it allows short-term operation during single-phase grounding faults, while small-resistance grounding has become mainstream for its fast fault removal and overvoltage limitation. Many substations install grounding tr
Felix Spark
06/12/2025
Discussion on the Design of Low Zero-Sequence Impedance Grounding Transformers
Discussion on the Design of Low Zero-Sequence Impedance Grounding Transformers
With the expansion of power system scale and the cableization process of urban power grids, the capacitive current in 6kV/10kV/35kV power grids has significantly increased (generally exceeding 10A). As power grids at this voltage level mostly adopt neutral ungrounded operation mode, and the distribution voltage side of main transformers is usually in delta connection, lacking a natural grounding point, the arc during ground faults cannot be reliably extinguished, necessitating the introduction o
Dyson
06/11/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放