• Arc-proof Air-insulated Switchgear for Primary Distribution  12kV 630...2000A 25kA
Arc-proof Air-insulated Switchgear for Primary Distribution 12kV 630...2000A 25kA
discuss personally
Model
LeanGear ZS9-12
Basic info
Brand ABB
Model NO. Arc-proof Air-insulated Switchgear for Primary Distribution 12kV 630...2000A 25kA
Rated voltage 12kV
Rated frequency 50/60Hz
Series LeanGear ZS9
Product Detail

Description:

LeanGear ZS9 is an arc-proof air-insulated switchgear designed to meet space requirements and ratings of low electrical distribution grids.

It offers optimal safety and reliability standards, consistent with the ABB’s UniGear range of switchgear. With a proven robustness and flexibility,  the LeanGear ZS9 is tested for tropical conditions.

Main benefits:

  • Safety: Increased safety level assured by integrated ducting system against effects of internal arc.
  • Security: Comprehensive interlocks provide optimum protection for both personnel and equipment.
  • Space: Maximum functionality in a compact design with reduced footprint and height.
  • Service: Ease of service and operation by personnel as switchgear and cable termination height are ergonomically designed.
  • Speed: Minimal service downtime attributable to modular circuit breaker design and built-in features that eliminate use of special handling tools.
  •  Strength: Robust panel structure that is proven against external mechanical impacts.

Main features:

  • Type-tested to IEC standard by STL lab.
  • Internal arc classification IAC AFLR 25kA 1s.
  • Classified as LSC2B, PM.
  • Up to 1250A, proven for severe climatic conditions compliant to IEC 62271-304 Class 2.
  • CB racking with closed door.
  • Cable termination height of 700 mm.
  •  IP4X degree of protection.
  • Extensible on both sides.
  • Integrate with ABB Relion® series relay for protection and control.
  •  For Higher Altitude contact ABB.

VInd/L circuit breaker:

  • Floor-rolling circuit breaker.
  • Suitable for E2, M2, and C2 endurance class application.
  •  Integral spring charging handle.
  •  Built-in mechanical anti-pumping device.

Single line diagram of typical units:

Typical feeder unit:

 A: Circuit breaker compartment
 B: Busbar compartment
 C: Cable compartment
 D: Low voltage compartment
 E: Integral panel gas duct

Know your supplier
ABB
As an authorized distributor of ABB products, we take great pride in our partnership.
Main Categories
High voltage/Low voltage
Business Type
Sales
Highest Annual Export (USD)
$580000000
Professional Experience
11 years
Workplace
20000m²
占位
占位
Documents
Public.
LeanGear ZS9 Arc-proof Air-insulated Switchgear for Primary Distribution
Manual English
PDF
FAQ
Q: What support and services does ABB provide for installation, commissioning, and after-sales maintenance?
A: ABB provides comprehensive support services including installation, commissioning, and after-sales maintenance. Our team of experts ensures smooth deployment and ongoing support to maximize the performance and longevity of our switchgear products.
Q: What smart solutions are available for ABB’s AIS portfolio?
A: ABB’s switchgear smart solutions are designed to help our customers make data-driven decisions. Our customers can benefit from a wide range monitoring, diagnostic, automation and control features for their ABB’s air-insulated medium voltage switchgear. Contact our sales team to learn more about ABB’s smart solutions for each of our switchgear.
Related Products
Related Knowledges
Modular Intelligent Substation - Prefabricated Secondary Switchgear Integration Assembly
Modular Intelligent Substation - Prefabricated Secondary Switchgear Integration Assembly
With the development of the national economy and society, the requirements for the quality and craftsmanship of power grid projects have become increasingly stringent. The need to improve the construction progress and quality of substations has created opportunities for the promotion of prefabricated cabin - type intelligent substations. The traditional on - site wiring and commissioning of secondary substation equipment involve a large amount of work. Moreover, on - site construction has to wai
Echo
06/13/2025
Application of Pre-integrated Prefabricated Substations in Renewable Energy Sector
Application of Pre-integrated Prefabricated Substations in Renewable Energy Sector
Against the backdrop of profound changes in the global energy landscape and the booming development of the new energy industry, the construction mode of traditional substations struggles to meet the rapid deployment needs of new energy projects. The modular intelligent prefabricated cabin substation, leveraging its innovative advantages, has become a key direction for optimizing the new energy power system. In - depth exploration of its technical principles, industry adaptability, and applicatio
Echo
06/13/2025
Research on Reliability Enhancement Scheme Implementation for Modular Intelligent Prefabricated Substations
Research on Reliability Enhancement Scheme Implementation for Modular Intelligent Prefabricated Substations
1 Implementation Strategies for the Scheme1.1 Deepen Survey and ResearchBefore constructing prefabricated cabin - type substations, it is necessary to conduct detailed surveys of local working conditions, clarify the construction scale and objectives, evaluate existing power facilities, plan projects, make up for infrastructure shortcomings, and adjust the construction rhythm. Meanwhile, control costs to avoid project suspension.1.2 Strengthen Structural ConstructionDuring promotion, multi - dim
Echo
06/13/2025
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
The secondary equipment area of conventional substations uses reinforced concrete or prefabricated steel structures, facing issues like long construction cycles, unreasonable functional zone design, strict environmental assessments, dust, noise, and disturbances. Primary and secondary equipment can only be installed after civil works and decoration, lowering construction efficiency.Prefabricated cabin substations integrate modularity, intelligence, and cost - effectiveness, boasting green, energ
Dyson
06/13/2025
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Under global climate diversity, alpine power construction faces technical and environmental challenges. Extreme climates, complex geology, and long - term low winter temperatures, along with ice, snow, and storms, strain electrical equipment stability and power facility construction (schedule, cost, maintenance). Traditional on - site substations, with long construction and poor adaptability, can’t meet alpine regions’ fast, stable power needs.Prefabricated cabin substations, as modu
Echo
06/13/2025
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Compact substation boxes, with advantages like safe operation, high reliability, and easy maintenance, are used in urban grid construction/renovation. Structurally divided into American - style (high - cost, noisy, low - efficiency, gradually phased out) and European - style (large - sized but more advantages, still popular).To address their pros/cons, ring - network prefabricated ones were developed.I. Basic Materials for Prefabricated Compact Substation BoxesMaterials need hardness, strength,
Echo
06/13/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放