• 6kV 10kV Series air-core current-limiting reactor
6kV 10kV Series air-core current-limiting reactor
discuss personally
Model
XKGKL-10/200-4
XKGKL-6/200-4
Basic info
Brand Wone
Model NO. Series air-core current-limiting reactor
Rated voltage 6kV
Rated normal current 200A
Reactance 4%
Series XKGKL
Product Detail

Description:

The current-limiting reactor is connected in series with the power system to limit the short-circuit current when the power system fails. When a short circuit occurs in the line, the current-limiting reactor uses its reactor characteristics to limit the short-circuit current of the line within a certain limit, so as to facilitate the smooth and effective removal of the fault of the switchgear. Current-limiting reactors generally use air-core reactors with good linearity of reactance values. The current-limiting reactor can operate safely and reliably at long-term rated current. In the case of failure, the ampere turns increase by several times or dozens of times, but its resistance value or the ability to limit the short-circuit current cannot be reduced, so the current-limiting reactor should be made into a hollow product rather than an iron-core product.

Feature:

  •  Multi-layer parallel air duct structure, epoxy glass fiber wrapping, uniform impact potential distribution, good ability to withstand short-circuit current.

  • Using computer-aided design, the structure and parameters of the product can be quickly and accurately determined according to the customer's requirements.

  •  The dry hollow form makes up for the disadvantages of oil leakage in the oil-immersed reactor, and there is no concern about core saturation, and the inductance value is linear.

  • The winding is wound with a variety of small cross-section film-wrapped wires, which has the characteristics of excellent insulation performance, low loss, light weight, small size, and maintenance-free.

  •  The entire outer surface of the reactor is coated with an anti-ultraviolet protective layer, which can be used indoors and outdoors, and the installation method is flexible, which can be stacked in three phases or arranged horizontally in three phases.

Technical indicators:

  • The parameters of rated voltage, rated current and supporting capacitors are shown in the technical parameter table.

  • Overload capacity: 1.35 times the rated current for continuous operation.

  • Thermal stability: It can withstand the rated current at the last of the rated reactance rate for 2s.

  • Dynamic stability performance: It can withstand 2.55 times of thermal stability current, time 0.5s, and no thermal mechanical damage.

  • Temperature rise: the average temperature rise of the coil is ≤ 75k (resistance method).

Parameters:

Insulation Level: LI60AC35, LI75AC42

企业微信截图_17331911257456.png

企业微信截图_17331915759690.png

企业微信截图_1733191282709.png

企业微信截图_17331917691924.png

企业微信截图_17331914508860.png

企业微信截图_17331915109334.png

What is the current limiting principle based on inductance of series air-core current limiting reactors?

Current Limiting Principle Based on Inductance:

  • According to Faraday's law of electromagnetic induction, when current flows through the windings of a reactor, it generates a magnetic field around the windings. This magnetic field, in turn, opposes the change in current, as described by Lenz's Law.

  • A series-connected air-core current-limiting reactor utilizes this principle. When a short-circuit fault or an excessive current occurs in the circuit, the inductance of the reactor impedes the rapid rise of the current, limiting its magnitude. This protects other equipment in the circuit from the impact of high currents.

  • For example, in a power transmission system, if a short circuit occurs on a line, the series-connected air-core current-limiting reactor will quickly increase the impedance of the circuit, preventing the short-circuit current from reaching excessively high values instantaneously. This provides additional time for protective devices, such as circuit breakers, to operate, ensuring the safety and stability of the system.


Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Application of Pre-integrated Prefabricated Substations in Renewable Energy Sector
Application of Pre-integrated Prefabricated Substations in Renewable Energy Sector
Against the backdrop of profound changes in the global energy landscape and the booming development of the new energy industry, the construction mode of traditional substations struggles to meet the rapid deployment needs of new energy projects. The modular intelligent prefabricated cabin substation, leveraging its innovative advantages, has become a key direction for optimizing the new energy power system. In - depth exploration of its technical principles, industry adaptability, and applicatio
Echo
06/13/2025
Research on Reliability Enhancement Scheme Implementation for Modular Intelligent Prefabricated Substations
Research on Reliability Enhancement Scheme Implementation for Modular Intelligent Prefabricated Substations
1 Implementation Strategies for the Scheme1.1 Deepen Survey and ResearchBefore constructing prefabricated cabin - type substations, it is necessary to conduct detailed surveys of local working conditions, clarify the construction scale and objectives, evaluate existing power facilities, plan projects, make up for infrastructure shortcomings, and adjust the construction rhythm. Meanwhile, control costs to avoid project suspension.1.2 Strengthen Structural ConstructionDuring promotion, multi - dim
Echo
06/13/2025
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
The secondary equipment area of conventional substations uses reinforced concrete or prefabricated steel structures, facing issues like long construction cycles, unreasonable functional zone design, strict environmental assessments, dust, noise, and disturbances. Primary and secondary equipment can only be installed after civil works and decoration, lowering construction efficiency.Prefabricated cabin substations integrate modularity, intelligence, and cost - effectiveness, boasting green, energ
Dyson
06/13/2025
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Under global climate diversity, alpine power construction faces technical and environmental challenges. Extreme climates, complex geology, and long - term low winter temperatures, along with ice, snow, and storms, strain electrical equipment stability and power facility construction (schedule, cost, maintenance). Traditional on - site substations, with long construction and poor adaptability, can’t meet alpine regions’ fast, stable power needs.Prefabricated cabin substations, as modu
Echo
06/13/2025
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Compact substation boxes, with advantages like safe operation, high reliability, and easy maintenance, are used in urban grid construction/renovation. Structurally divided into American - style (high - cost, noisy, low - efficiency, gradually phased out) and European - style (large - sized but more advantages, still popular).To address their pros/cons, ring - network prefabricated ones were developed.I. Basic Materials for Prefabricated Compact Substation BoxesMaterials need hardness, strength,
Echo
06/13/2025
The design of the three-purpose grounding transformer
The design of the three-purpose grounding transformer
Underground Power Cable Transmission LinesDirect - buried power cable lines have large ground - distributed capacitance, causing high single - phase - to - ground short - circuit capacitive current. For 10 kV lines, if this current exceeds 10 A, arcs hardly self - extinguish, risking arc overvoltage and endangering line equipment. Arc extinction is thus necessary. With a Dyn - connected main transformer, an arc - suppression coil on the secondary neutral point suffices. For Yd - connected ones,
Dyson
06/12/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放