• Low-Loss Three-Phase Photovoltaic Isolation Transformer
Low-Loss Three-Phase Photovoltaic Isolation Transformer
discuss personally
Model
SG-1250kVA
SG-300kVA
Basic info
Brand ROCKWILL
Model NO. Low-Loss Three-Phase Photovoltaic Isolation Transformer
Rated frequency 50/60Hz
Rated capacity 1250kVA
Phases Three-phase
Series SGG
Product Detail

Product Overview:

For many years, our company has specialized in manufacturing SD/SG(YSD) series single-phase and three-phase dry-type transformers dedicated to mechanical equipment, with capacities ranging from 1KVA to 3000KVA. Developed by referencing the latest similar products from Siemens, our SG series three-phase dry-type transformers not only provide voltage transformation in the power grid but also isolate third harmonics from the grid to equipment, reducing heat generation in machines and extending the service life of insulating materials. They are particularly suitable for imported equipment (380V input → 220V output, 380V input → any voltage output, 220V input → any voltage output) with specifications from 1KVA to 3000KVA.

Our SG and DG series dry-type isolation transformers are widely applicable to various power supply scenarios with AC 50-60HZ and input/output voltages not exceeding 3000V. All parameters, including input/output voltage levels, connection groups, tap positions, winding capacity distribution, secondary winding configurations, and whether a casing is required, are meticulously designed and manufactured according to user requirements.

Material Configuration Description of Transformer:

Transformers serve as the main components of various power supplies and electrical equipment. Isolation transformers consist of cylindrical windings and laminated cores, where the core is stacked with brand-new high-quality high-silicon silicon steel sheets using fully mitered joints. Our company employs advanced manufacturing processes, including imported Max high-speed automatic winding machines and a full set of vacuum pressure impregnation (VPI) equipment. The windings are formed using the skeletonless full-series winding method, and the transformers undergo vacuum impregnation to achieve insulation classes of F (155℃) or H (180℃).The input and output voltages of the transformer can be designed according to customer requirements, available in various specifications such as single-phase, three-phase, or multiple-way input/output configurations.

  •  Core:Made of brand-new high-quality high-silicon silicon steel sheets, mainly with materials of 0.35mm thick H18, H14, H12, and Z11 high-quality silicon steel sheets. We select the most suitable material based on customer requirements and usage conditions to optimize the transformer's performance design. (Conventional material: brand-new high-quality silicon steel sheets).

  • Wire:Using PEW, UEW, EIW, SEIW, FEAI enameled wires and glass fiber-covered wires, with temperature resistance grades of F (155℃), H (180℃), HC (200℃), and C (220℃). (Conventional temperature resistance grade: H grade, 180℃).

  • Insulating Materials:Adopting high-temperature resistant insulating paper as the insulating material, which has multiple properties of high-temperature insulation, flame retardancy, and moisture resistance.

  •  Insulating Material Terminal Blocks

  • For low-power applications: Using terminal blocks, which feature a beautiful appearance and excellent voltage resistance, temperature resistance, and flame retardant properties.

  • For high-power applications: Using high-quality copper busbars.

  •  Iron Feet:Mainly made of CNC bent cold-rolled steel plates, with environmentally friendly electroplating options such as multicolor plating (golden yellow), blue zinc (silver white), white zinc (ivory white), and surface anodizing (black).

Technical data:

Product Operating Conditions:

  • Applicable altitude: ≤ 5000m

  • Ambient temperature: -15℃~+45℃

  • Relative humidity: ≤ 90%

  • The installation site shall be free of gases, vapors, chemical deposits, dirt, conductive dust that seriously affect the insulation strength of the transformer, and free of other explosive, flammable, and corrosive substances.

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
What tests need to be conducted on current transformers?
What tests need to be conducted on current transformers?
By Oliver, 8 Years in the Electrical IndustryHi everyone, I'm Oliver, and I've been working in the electrical industry for 8 years.From early days doing substation equipment commissioning to now managing protection and metering configurations for entire distribution systems, one of the most frequently used devices in my work has been the Current Transformer (CT).Recently, a friend who's just starting out asked me:“How do you test current transformers? Is there a simple and effective way to
Oliver Watts
07/04/2025
What should be noted when choosing a current transformer for a 10kV station transformer circuit?
What should be noted when choosing a current transformer for a 10kV station transformer circuit?
Practical Experience Sharing from an Electrical Engineer in the FieldBy James, 10 Years in the Electrical IndustryHi everyone, I'm James, and I've been working in the electrical industry for 10 years.From early involvement in substation design and equipment selection, to later taking charge of relay protection and automation system commissioning for entire projects, one of the most frequently used devices in my work has been the current transformer (CT).Recently, a friend who's just starting out
James
07/04/2025
What are the application and improvement directions of current transformers in power systems?
What are the application and improvement directions of current transformers in power systems?
As a front - line power operation and maintenance worker, I deal with current transformers (CTs) daily. Having witnessed the popularization of new photoelectric CTs and tackled numerous faults, I’ve gained practical insights into their application and testing improvements. Below, I’ll share my on - site experience with new CTs in power systems, aiming for a balance between professionalism and practicality.1. Application of New CTs in Power Systems1.1 CTs in Power SystemsMost new CTs
Echo
07/04/2025
What are the troubleshooting methods for current transformers?
What are the troubleshooting methods for current transformers?
As a front - line fault maintenance worker, I deal with current transformers (CTs) daily. A CT’s secondary winding in operation must never open - circuit! Once open - circuited, the secondary current and demagnetizing potential vanish. All primary - side magnetic potential then becomes the iron core’s exciting potential, sharply increasing its magnetic flux density. High voltage on the secondary side will endanger safety anytime.Despite strict power operation regulations, user electr
Felix Spark
07/04/2025
What are the criteria for selection of distribution transformer?
What are the criteria for selection of distribution transformer?
Transformer Selection Criteria: Essential Factors for Optimal PerformanceSelecting the appropriate transformer is critical for ensuring power distribution reliability across industrial, commercial, and residential systems. This process requires meticulous evaluation of load dynamics, environmental constraints, and regulatory standards. Below we outline key selection criteria to guide engineers and designers in making informed decisions.1. Maximum Demand AssessmentThe transformer’s capacity (kVA)
Master Electrician
07/03/2025
What are the causes of current transformer faults and the countermeasures for faults?
What are the causes of current transformer faults and the countermeasures for faults?
As a front - line maintenance technician, I deal with current transformers (CTs) daily. CTs convert high - magnitude primary current to low - magnitude secondary current for substation/line protection and measurement, operating in series long - term. However, they face faults from external (unbalanced loads, wrong wiring, etc.) and internal (insulation defects) issues. These faults, like secondary open - circuits or insulation breakdown, harm measurement accuracy, protection operation, and grid
Felix Spark
07/03/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!