• PG208 Protected Pressure Transmitter
  • PG208 Protected Pressure Transmitter
  • PG208 Protected Pressure Transmitter
  • PG208 Protected Pressure Transmitter
PG208 Protected Pressure Transmitter
$40.00
Model
PG208
Basic info
Brand Wone
Model NO. PG208 Protected Pressure Transmitter
Power supply 9~30VDC
Type of pressure Gauge pressure
display Yes
Series PG208
Product Detail

Description

The protective pressure transmitter adopts imported silicon wafers, with high precision and stable performance; As a sensing element, the silicon piezoresistive pressure core has a built-in processing circuit that converts the millivolt signal of the sensor into a standard voltage and current signal, and combines it with the unit instrument, DCS system, PLC, etc. to form an automatic control system, which is an ideal pressure measuring instrument in the field of industrial automation. It is an ideal pressure measuring instrument in the field of industrial automation to form an automatic control system.

Industry applications

It is widely used in various industrial fields (automation equipment and petroleum, chemical, natural gas, energy, etc.) where fluid pressure needs to be measured.

Features

Diaphragm isolation technology is adopted, which has high stability and high reliability.

Integrated chip, wide voltage power supply.

 Integral die-cast aluminum structure, strong and reliable.

 Frequency cut-off design, strong anti-interference ability, lightning protection.

Current limiting, voltage limiting, reverse polarity protection (current limiting output).

High precision, good stability, fast response speed and impact resistance.

Technical parameters

Measuring medium Liquids or gases (compatible with contact materials)
Pressure range - 100 k Pa~ 0 ~ 100 MPa
Pressure mode Gauge pressure, absolute pressure, negative pressure
Output signal 4 ~ 20 m A 0 ~ 10 VDC 0 ~ 5 VDC RS 485 customized
Supply voltage 9 ~ 30 VDC
Accuracy class ± 0.25 % FS ± 0.5 % FS Header display accuracy 0 . 5-level, digital tube (LED) display
working conditions Medium temperature - 40 ~ 80 °C Ambient temperature - 40 ~ 80 °C
Seismic performance 10 g( 20 ... 2000 Hz)
Overload capacity 1.5 times ~ 5 times
Frequency of response Analog signal output ≤ 500 Hz and digital signal output ≤ 5 Hz
Stable performance ± 0 . 1 % FS/year
Temperature drift ±0 . 01 % FS/ °C (within temperature compensation)
Ingress protection IP 65 IP 66
Explosion-proof type Flameproof ExdII.CT 6 Gb Intrinsically Safe ExiaII.CT 6 Ga
Load characteristics Current load ≤{(Us- 7.5 )÷ 0.02 ( Us=supply voltage)}Ω Voltage load≥ 100 k Ω

Product show

企业微信截图_17157381573209.png

企业微信截图_17157381856397.png

     企业微信截图_17157382114987.png

企业微信截图_17157382354458.png




Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Failure Analysis and Design Optimization of Conventional Grounding Transformers
Failure Analysis and Design Optimization of Conventional Grounding Transformers
I. Core Cause of Damage: Electrodynamic Impact (Complying with GB/T 1094.5 / IEC 60076-5)The direct cause of high-voltage winding end collapse is the instantaneous electrodynamic impact induced by short-circuit current. When a single-phase grounding fault occurs in the system (such as lightning overvoltage, insulation breakdown, etc.), the grounding transformer, as the fault current path, withstands high-amplitude and steep-rise-rate short-circuit currents. According to Ampère's force law
Felix Spark
06/12/2025
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
1 Theoretical AnalysisIn distribution networks, grounding transformers serve two key roles: powering low - voltage loads and connecting arc - suppression coils at neutrals for grounding protection. Grounding faults, the most common distribution network fault, heavily impact transformers’ operating characteristics, causing sharp changes in electromagnetic parameters and status.To study transformers’ dynamic behaviors under single - phase grounding faults, build this model: Assume a tr
Felix Spark
06/12/2025
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
1 Classification of Neutral Grounding Methods for Solar Photovoltaic Power StationsInfluenced by differences in voltage levels and grid structures across regions, the neutral grounding methods of power systems are mainly categorized into non-effective grounding and effective grounding. Non-effective grounding includes neutral grounding via arc suppression coils and neutral ungrounded systems, while effective grounding comprises neutral solid grounding and neutral grounding via resistors. The sel
Dyson
06/12/2025
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
In a neutral-insulated three-phase power system, an earthing transformer provides an artificial neutral point, which can be solidly earthed or earthed via reactors/arc suppression coils. The ZNyn11 connection is typical, where zero-sequence magnetomotive forces in the inner/outer half-windings of the same core column cancel out, balancing fault currents in series windings and minimizing zero-sequence leakage flux/impedance.Zero-sequence impedance is critical: it determines fault current magnitud
Dyson
06/12/2025
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
The neutral grounding mode refers to the connection between the power system neutral point and ground. In China's 35 kV and below systems, common methods include ungrounded neutral, arc-suppression coil grounding, and small-resistance grounding. The ungrounded mode is widely used as it allows short-term operation during single-phase grounding faults, while small-resistance grounding has become mainstream for its fast fault removal and overvoltage limitation. Many substations install grounding tr
Felix Spark
06/12/2025
Discussion on the Design of Low Zero-Sequence Impedance Grounding Transformers
Discussion on the Design of Low Zero-Sequence Impedance Grounding Transformers
With the expansion of power system scale and the cableization process of urban power grids, the capacitive current in 6kV/10kV/35kV power grids has significantly increased (generally exceeding 10A). As power grids at this voltage level mostly adopt neutral ungrounded operation mode, and the distribution voltage side of main transformers is usually in delta connection, lacking a natural grounding point, the arc during ground faults cannot be reliably extinguished, necessitating the introduction o