• Intelligent Dual Power Controller
  • Intelligent Dual Power Controller
Intelligent Dual Power Controller
discuss personally
Model
RWD-LCN-SP
Basic info
Brand RW Energy
Model NO. Intelligent Dual Power Controller
Rated voltage 230V ±20%
Rated frequency 50/60Hz
Electric energy consumption ≤5W
Series RWD-LC
Product Detail

Description

With the development of society, people have higher and higher requirements for power supply reliability. In many cases, two power supplies are used to ensure the reliability of power supply, which requires a product to switch reliably between two power supplies. The intelligent dual power automatic conversion device produced by our company is mainly composed of a high-voltage vacuum circuit breaker with electric dual isolation and a dual power intelligent backup self-input controller. Applied to AC 50HZ, rated voltage 12KV, rated current up to 1250A dual power supply system, when one power failure or undervoltage occurs, the isolation switch automatically switches to the other, the whole process automatically switches to the other normal power supply. Reliable guarantee of continuity of power supply

The controller has a variety of protection functions such as short circuit, three-stage overcurrent, single-phase ground, undervoltage, reclosing and prepaid, which effectively avoids unnecessary re-supply shock when the load fails. When the common power supply fails, the switching device can automatically switch with the standby power supply to ensure reliability and safety. It is especially suitable for important places where power is not allowed, as an important electrical control device to ensure continuous power supply, it is a self-throwing self-restoring dual power automatic switching device matching with high voltage vacuum circuit breaker. The products are widely used in 10kV distribution lines in oil fields and mines, and 10kV lines in industrial and mining enterprises to ensure real-time power supply of important loads. It has the characteristics of small footprint, small investment, convenient debugging and maintenance, and is an ideal switchgear for realizing power supply automation.

Support communication methods: wireless (GSM/GPRS/CDMA), Ethernet, WIFI, optical fiber, power carrier, RS232/485,RJ45, etc., and can access other station equipment (such as TTU, FTU, DTU, etc.).

Main function introduction

1. Protection relay functions:

AST    Double line Protection,

49     Thermal Overload (Over load), 

50 Three-section of Overcurrent (Ph.OC),

50G/N/SEF Sensitive Earth Fault (SEF),

27/59 Under/Over Voltage (Ph.OV/Ph.UV), 

51C Cold load pickup (Cold load).

2. Supervision functions:

60CTS CT Supervision,

60VTS VT Supervision. 

3. Control functions:

79 Auto Reclose,

86 Lockout>>>>>>.

circuit-breaker control.

4. Monitoring Functions: 

1) Primary currents for Phases and Zero sequence current,

2) Primary PT Voltage,

3) Frequency,

4) Binary Input/Output status, 

5) Trip circuit healthy/failure,

6) Time and date,

7) Fault records,

8) Event records.

5. Data Storage functions:

1) Event Records,

2) Fault Records,

3) Measurands

Technology parameters

 paramete.png

Device structure

RWD-LC-尺寸.png

双电源控制器的应用方案.png

About customization

The following optional functions are available: Upgrade SMS Function. Upgrade RS485/RS232 socket.

For detailed customization, please contact the salesman.

Q: What is a high voltage dual power switch?

A: The high-voltage dual power switch is a device used to automatically switch between two high-voltage power supplies. When one power supply fails (such as power failure, abnormal voltage, etc.), it can quickly switch the load to another normal power supply to ensure the continuity of power supply.

Q: Where is it mainly used?

A: In hospitals, data centers, large factories and other places where continuity of power supply is highly required. For example, during hospital surgery, a sudden power outage may endanger the patient's life, and the use of high-voltage dual power switch can avoid this situation.

Q: How fast does it switch?

A: Generally speaking, the switching time can reach the millisecond level, which can minimize the time of load power failure and avoid damage to the equipment.

Know your supplier
RW Energy
Zhejiang Rockwell Energy Technology Co., Ltd. is an international enterprise specializing in the research, development and manufacturing of recloser controllers, power quality management, power monitoring systems and other high-end power equipment. In today's critical period of global energy transition and power system upgrading, the company has gathered a group of top talents in the fields of power engineering, automation control, software development, etc., who carry the enthusiasm and persistence for the power business, and are committed to overcoming the complex problems in the power system, and promoting the intelligent development of the power industry with innovative technology. Mission: To make global electricity smarter, more reliable and more efficient with innovative technology. Vision: To be the leader in global power intelligence.
Main Categories
High voltage/New energy/Tester
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$100000000
Professional Experience
12 years
Workplace
30000m²
占位
占位
Documents
Public.
Intelligent Dual Power Controller
Manual English
Consulting
Related Products
Related Knowledges
What are the common failures in single-phase distribution transformers?
What are the common failures in single-phase distribution transformers?
Single - phase distribution transformers, as crucial voltage transformation and power distribution equipment in the power system, are widely used in rural power grids, low - voltage residential areas, and areas with concentrated single - phase loads.With the continuous increase in the proportion of single - phase loads in the distribution network, the failure rate of single - phase transformers has also increased. Timely identification and handling of these faults are of great significance for e
Felix Spark
06/18/2025
Comprehensive Analysis of Single-Phase Distribution Transformer Technologies in Multiple Application Scenarios
Comprehensive Analysis of Single-Phase Distribution Transformer Technologies in Multiple Application Scenarios
Introduce the 10 kV line to the load center. Following “small capacity, dense points, short radius”, adopt the new single - phase distribution mode, featuring notable low - voltage line loss reduction, high power quality, and reliability. By comparing the economy and reliability of single - phase vs three - phase transformers in different scenarios, this paper analyzes their applicable scope and application suggestions.Single - phase transformers are classified by distribution mode:
Echo
06/18/2025
What are the technical features and applications of single-phase distribution transformers?
What are the technical features and applications of single-phase distribution transformers?
1 Technical Features of Single - phase TransformersFrom the operation practice of foreign distribution networks, it is known that single - phase transformers are quite widely applied. Compared with three - phase transformers, they have unique advantages, which are specifically reflected as follows:1.1 Simple StructureThis characteristic makes that, when using the same materials, for single - phase transformers with the same capacity, their no - load losses are lower than those of three - phase t
Echo
06/17/2025
Application Analysis of High-Voltage Single-Phase Distribution Transformers in Power Distribution Networks
Application Analysis of High-Voltage Single-Phase Distribution Transformers in Power Distribution Networks
1. Safety Hazards in Substation Operation1.1Transformer FailuresTransformers are critical substation equipment and maintenance focal points. Loose/defective components often cause malfunctions, while internal damage (e.g., oil tank impurities/water/bubbles) triggers partial discharge, risking major losses during outages.1.2 Overvoltage RisksOutdoor overvoltage threatens equipment. Lightning-induced impulse currents alter transformer electromagnetic energy, and circuit breaker misoperations cause
Echo
06/17/2025
Prototype Development of 20 kV Single-Phase Distribution Transformer
Prototype Development of 20 kV Single-Phase Distribution Transformer
1. Design of 20 kV Single - phase Distribution Transformer20 kV distribution systems usually adopt cable lines or mixed cable - overhead line networks, and the neutral point is mostly grounded through a small resistance. When a single - phase grounding occurs, there will be no problem that the phase voltage will rise by more than √3 times as in the case of a single - phase fault in a 10 kV system. Therefore, the single - phase distribution transformer of the 20 kV system can adopt the type
Dyson
06/17/2025
Single-Phase Transformer with High Lightning Impulse Withstand Capability
Single-Phase Transformer with High Lightning Impulse Withstand Capability
1 IntroductionTo ensure the safe operation of railways and reduce the risk of lightning damage to railway telecommunication control systems, the author has specially researched and designed a single - phase series transformer with a relatively high impulse voltage withstand level, with the model number D10 - 1.2 - 30/10. This transformer is equipped with an oil conservator and adopts a fully sealed structure (it can also be designed as a dry - type structure according to actual needs). This seri
Dyson
06/17/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放