• MC Series Flexible Cable For Coal-mining
  • MC Series Flexible Cable For Coal-mining
MC Series Flexible Cable For Coal-mining
discuss personally
Model
TYPE A MC-0.38/0.66
Basic info
Brand Wone
Model NO. MC Series Flexible Cable For Coal-mining
Rated voltage 0.38/0.66kV
芯数 3+1+3-core
alloy code TU2
Series MC
Product Detail

Application

It is suitable for rated voltage Uo/U 1.9/3.3KV coalmining machine and the similar equipments.

Application conditions

The long-term permissible working temperature of cable conductor for rated voltage up to and including 0.38/0.66kV is 90 ,Black jacket.

The long-term permissible working temperature of cable conductor for rated voltage up to and including 0.66/1.44kV is 90 ,Yellow jacket . and that of the cable conductor of rated voltage1.9/3.3kV is 90℃ It’s smallest bending radiusis 6 times than the size of cable diameter. The yellow sheathed cables can’t be exposed in the sun for a long time.

Model and names

用途.png

Structure diagram

结构.png

Specification size

Rated voltage 0.66/1.14kV cable dimensions

规格.png

Rated voltage 0.38/0.66kV cable dimensions

规格2.png

 Rated voltage 1.9/3.3kV cable dimensions

规格3.png

Technical parameter

Finished DC resistance

 技术特性1.png

Finished insulation resistance

技术特性2.png

    a. Conductor temperature of  90℃ to allow work;

    b. it has the anti-bending characteristics;

    c. it has the anti-extrusion and anti-pressure characteristics;

    d. Insulation tensile strength greater than 6.5Mpa, more than 200% elongation;

    e. Max anti-bending 11.0 N/mm2, Max anti-tensible force>250%;

    f. No damage under rated voltage 0.38/0.66kV for 3.0kV/5min,0.66/1.14kV for 3.7kV/5min, 1.9/3.3kV for 6.8kV/0.5min respectively;

    g. It complies with fire-proof feature based on MT386-1995.


Q: What is MC cable? 

A: MC Cable is Metal Clad Cable. It consists of a combination of insulated wires and is covered with a metal sheath. This cable has good mechanical protection performance and can resist external physical damage such as extrusion and collision to a certain extent. 

Q: What are the main application scenarios of MC cables? 

A: MC cable is often used in commercial buildings, industrial facilities, mining sites and other places. In commercial buildings, such as shopping malls, office buildings, etc., it can be used for electrical wiring systems to power lighting, sockets and other equipment. In industrial facilities, such as factory floors, due to the complex environment, the metal sheathing of MC cables can provide additional protection and is suitable for connecting power to various types of machines and equipment. Because of its excellent defensive performance, it is often used in mining, metallurgy and other fields. 

Q: What are the advantages of MC cable? 

A: Its advantages include high safety, metal sheath can be used as a grounding path; The installation is relatively flexible, and can be laid under a variety of ways such as bridge and cable trough. And has a good electromagnetic compatibility, can reduce the electromagnetic interference to the surrounding equipment.



Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
The design of the three-purpose grounding transformer
The design of the three-purpose grounding transformer
Underground Power Cable Transmission LinesDirect - buried power cable lines have large ground - distributed capacitance, causing high single - phase - to - ground short - circuit capacitive current. For 10 kV lines, if this current exceeds 10 A, arcs hardly self - extinguish, risking arc overvoltage and endangering line equipment. Arc extinction is thus necessary. With a Dyn - connected main transformer, an arc - suppression coil on the secondary neutral point suffices. For Yd - connected ones,
Dyson
06/12/2025
Failure Analysis and Design Optimization of Conventional Grounding Transformers
Failure Analysis and Design Optimization of Conventional Grounding Transformers
I. Core Cause of Damage: Electrodynamic Impact (Complying with GB/T 1094.5 / IEC 60076-5)The direct cause of high-voltage winding end collapse is the instantaneous electrodynamic impact induced by short-circuit current. When a single-phase grounding fault occurs in the system (such as lightning overvoltage, insulation breakdown, etc.), the grounding transformer, as the fault current path, withstands high-amplitude and steep-rise-rate short-circuit currents. According to Ampère's force law
Felix Spark
06/12/2025
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
1 Theoretical AnalysisIn distribution networks, grounding transformers serve two key roles: powering low - voltage loads and connecting arc - suppression coils at neutrals for grounding protection. Grounding faults, the most common distribution network fault, heavily impact transformers’ operating characteristics, causing sharp changes in electromagnetic parameters and status.To study transformers’ dynamic behaviors under single - phase grounding faults, build this model: Assume a tr
Felix Spark
06/12/2025
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
1 Classification of Neutral Grounding Methods for Solar Photovoltaic Power StationsInfluenced by differences in voltage levels and grid structures across regions, the neutral grounding methods of power systems are mainly categorized into non-effective grounding and effective grounding. Non-effective grounding includes neutral grounding via arc suppression coils and neutral ungrounded systems, while effective grounding comprises neutral solid grounding and neutral grounding via resistors. The sel
Dyson
06/12/2025
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
In a neutral-insulated three-phase power system, an earthing transformer provides an artificial neutral point, which can be solidly earthed or earthed via reactors/arc suppression coils. The ZNyn11 connection is typical, where zero-sequence magnetomotive forces in the inner/outer half-windings of the same core column cancel out, balancing fault currents in series windings and minimizing zero-sequence leakage flux/impedance.Zero-sequence impedance is critical: it determines fault current magnitud
Dyson
06/12/2025
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
The neutral grounding mode refers to the connection between the power system neutral point and ground. In China's 35 kV and below systems, common methods include ungrounded neutral, arc-suppression coil grounding, and small-resistance grounding. The ungrounded mode is widely used as it allows short-term operation during single-phase grounding faults, while small-resistance grounding has become mainstream for its fast fault removal and overvoltage limitation. Many substations install grounding tr
Felix Spark
06/12/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放