• Long-Lasting 800V/800V Photovoltaic Transformer for Continuous Solar Energy Supply
Long-Lasting 800V/800V Photovoltaic Transformer for Continuous Solar Energy Supply
discuss personally
Model
SGG-80kVA
Basic info
Brand ROCKWILL
Model NO. Long-Lasting 800V/800V Photovoltaic Transformer for Continuous Solar Energy Supply
Rated frequency 50/60Hz
Rated capacity 80kVA
Series SGG
Product Detail

Product Overview:

Our 80KVA Photovoltaic Transformer is specifically engineered for solar energy applications, ensuring high efficiency, reliability, and durability in PV power systems. Designed for three-phase solar installations, it delivers stable voltage conversion (220VAC to 440VAC) with low losses and excellent thermal performance, making it ideal for continuous solar energy supply in commercial and industrial settings.

Product Features:

  • Superior Electrical Performance: Low Short-Circuit Impedance (4%) – Ensures stable voltage regulation High Insulation Resistance (>100MΩ @500VDC) – Prevents leakage and breakdown 2500VAC/min Voltage Withstand – No puncture or breakdown under high voltage stress
  • Premium Materials & Construction:Winding Material: High-temperature (200°C) copper/aluminum wire for enhanced conductivity Core Material: Baosteel B50A470 silicon steel – Low no-load loss and reduced heat generation Connection Mode: Y (Star) configuration (customizable to Delta or other requirements)
  • Reliable Thermal Management:Temperature Rise Limit: 100K – Ensures safe operation under continuous load Natural Cooling / Optional Fan Cooling – Adaptable to different cooling needs.
  • Durability & Safety:Indoor Protection (IP20) – Suitable for controlled environments 12-Hour Aging Test Before Shipment – Guarantees long-term reliability 2-Year Warranty – Full coverage for manufacturing defects
  • Customization Options:Voltage Adjustments (Input/Output) Cooling System Upgrade (Fan-assisted) Branding & Packaging (Logo printing available)

Technical parameters:

Product Advantages:

  • Optimized for Solar Applications – Designed to handle PV system fluctuations and harmonic loads.
  • High Efficiency & Low Losses – Premium materials ensure minimal energy waste Robust Overload Capacity – Withstands 300%
  • Overload for 10 sec / 150% for 120 min
  • Long Service Life – Class H insulation (200°C) and high-quality Baosteel B50A470 silicon steel core Fast Delivery – Standard units ready in 7 working days (10+ pcs) Global Compliance – CE, RoHS, and ISO 9001 certified.
Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
What tests need to be conducted on current transformers?
What tests need to be conducted on current transformers?
By Oliver, 8 Years in the Electrical IndustryHi everyone, I'm Oliver, and I've been working in the electrical industry for 8 years.From early days doing substation equipment commissioning to now managing protection and metering configurations for entire distribution systems, one of the most frequently used devices in my work has been the Current Transformer (CT).Recently, a friend who's just starting out asked me:“How do you test current transformers? Is there a simple and effective way to
Oliver Watts
07/04/2025
What should be noted when choosing a current transformer for a 10kV station transformer circuit?
What should be noted when choosing a current transformer for a 10kV station transformer circuit?
Practical Experience Sharing from an Electrical Engineer in the FieldBy James, 10 Years in the Electrical IndustryHi everyone, I'm James, and I've been working in the electrical industry for 10 years.From early involvement in substation design and equipment selection, to later taking charge of relay protection and automation system commissioning for entire projects, one of the most frequently used devices in my work has been the current transformer (CT).Recently, a friend who's just starting out
James
07/04/2025
What are the application and improvement directions of current transformers in power systems?
What are the application and improvement directions of current transformers in power systems?
As a front - line power operation and maintenance worker, I deal with current transformers (CTs) daily. Having witnessed the popularization of new photoelectric CTs and tackled numerous faults, I’ve gained practical insights into their application and testing improvements. Below, I’ll share my on - site experience with new CTs in power systems, aiming for a balance between professionalism and practicality.1. Application of New CTs in Power Systems1.1 CTs in Power SystemsMost new CTs
Echo
07/04/2025
What are the troubleshooting methods for current transformers?
What are the troubleshooting methods for current transformers?
As a front - line fault maintenance worker, I deal with current transformers (CTs) daily. A CT’s secondary winding in operation must never open - circuit! Once open - circuited, the secondary current and demagnetizing potential vanish. All primary - side magnetic potential then becomes the iron core’s exciting potential, sharply increasing its magnetic flux density. High voltage on the secondary side will endanger safety anytime.Despite strict power operation regulations, user electr
Felix Spark
07/04/2025
What are the criteria for selection of distribution transformer?
What are the criteria for selection of distribution transformer?
Transformer Selection Criteria: Essential Factors for Optimal PerformanceSelecting the appropriate transformer is critical for ensuring power distribution reliability across industrial, commercial, and residential systems. This process requires meticulous evaluation of load dynamics, environmental constraints, and regulatory standards. Below we outline key selection criteria to guide engineers and designers in making informed decisions.1. Maximum Demand AssessmentThe transformer’s capacity (kVA)
Master Electrician
07/03/2025
What are the causes of current transformer faults and the countermeasures for faults?
What are the causes of current transformer faults and the countermeasures for faults?
As a front - line maintenance technician, I deal with current transformers (CTs) daily. CTs convert high - magnitude primary current to low - magnitude secondary current for substation/line protection and measurement, operating in series long - term. However, they face faults from external (unbalanced loads, wrong wiring, etc.) and internal (insulation defects) issues. These faults, like secondary open - circuits or insulation breakdown, harm measurement accuracy, protection operation, and grid
Felix Spark
07/03/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!