• JSZV16-24R Voltage Transformer (with fuse)
JSZV16-24R Voltage Transformer (with fuse)
discuss personally
Model
JSZV16-24R-11kV
Basic info
Brand Wone Store
Model NO. JSZV16-24R Voltage Transformer (with fuse)
Rated frequency 50/60Hz
Primary voltage 11kV
Secondary voltage 100/220V
Series JSZV
Product Detail

Product Overview

JSZV16-24R voltage transformer, epoxy resin casting and full enclosed construction, is used indoor for measuring current, electric energy and protective relaying in single-phase or three-phase AC circuit with the frequency 50Hz or 60Hz and highest voltage for equipement 12kV.

The product has the feature of high reliability, low magnetism of core, large creepage distance of external insulation and maintenance free etc.

Key Features

  • Integrated Overvoltage Protection with Fuse:The JSZV16 - 24R Voltage Transformer comes with an integrated fuse. This fuse is designed to offer reliable overvoltage protection. In case of abnormal voltage surges in the 24kV power system, it quickly cuts off the circuit, safeguarding the transformer and other connected electrical equipment from potential damage due to excessive voltage. This not only enhances the safety of the power system but also extends the lifespan of the voltage transformer.
  • Precise Voltage Measurement:Engineered with high - precision components and advanced design, the JSZV16 - 24R can accurately convert the 24kV high - voltage in the primary side to low - voltage signals in the secondary side. The error is strictly controlled within a narrow range. Whether it is for power metering, voltage monitoring, or providing signals for relay protection devices, it ensures that the measured voltage values are highly accurate, enabling stable and efficient operation of the power system.
  • Compact and Space - saving Structure:Featuring a compact structure, this voltage transformer takes up minimal space. Its design is optimized for installation in various settings, especially in switch cabinets and substations where space might be limited. Despite its small size, it doesn't compromise on performance. The compactness also makes transportation and installation more convenient, reducing both the installation space requirements and the associated costs.

Main technical parameter

  • Highest voltage for equipment: 12kV
  • Rated primary voltage: 11kV
  • Rated secondary voltage: 100/220V or 110/220V or 100V or 110V.
  • Technical standard accords with IEC 60044-2:2003 Part2 Instrument transformers-Part2: inductive voltage transformers

Remarks: Upon request we are glad to offer transformers according to other standards or with non-standard technical specs.

 

Know your supplier
Wone Store
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment/MV & LV CT PT/Switchgear parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
What should be noted when selecting and installing GIS voltage transformers?
What should be noted when selecting and installing GIS voltage transformers?
In power systems, voltage transformers in GIS (Gas Insulated Switchgear) play a crucial role in voltage measurement and relay protection. Selecting the right model and installing it correctly is vital for the stable operation of the equipment. The following points should be noted regarding selection and installation.I. Key Points for Selection(1) Matching Rated ParametersVoltage Level: It must be consistent with the voltage level of the GIS system. For example, 110kV and 220kV GIS systems requir
James
07/08/2025
What are the causes of the breakdown and burning of the 35 kV GIS voltage transformer?
What are the causes of the breakdown and burning of the 35 kV GIS voltage transformer?
1. Accident Overview1.1 Structure and Connection of 35kV GIS Switchgear Voltage TransformerThe ZX2 gas-insulated double-bus switchgear, manufactured in March 2011 and officially put into operation in July 2012, is configured with two groups of bus voltage transformers (PTs) for each bus section. The two PT groups of the same bus section are designed in one switchgear cabinet with a width of 600 mm. The three-phase PTs are arranged in a triangular formation at the bottom of the cabinet.The PTs ar
Felix Spark
07/08/2025
What Are the Steps for Error Testing GIS Voltage Transformers?
What Are the Steps for Error Testing GIS Voltage Transformers?
Hey everyone, I'm Oliver, and I've been working with current transformers (CTs) and voltage transformers (VTs) for 8 years.From assisting my mentor on site to leading high-voltage testing teams and conducting error calibrations independently, I’ve dealt with all kinds of instrument transformers — especially those used in GIS systems. The error test for voltage transformers is something I perform regularly.A few days ago, a friend asked me:“Oliver, how exactly do you perform an
Oliver Watts
07/08/2025
An GIS Equipment Explosion Accident Caused by PT Secondary Wiring Errors
An GIS Equipment Explosion Accident Caused by PT Secondary Wiring Errors
1. Accident OverviewA newly - built 110kV substation’s GIS exploded during commissioning due to a PT secondary circuit short - circuit. Though the cause was simple, consequences were severe, warranting reflection.2. Accident ProcessOn the power - transmission day:The upper - level power supply charged the 110kV GIS (a combined appliance).20s after closing the incoming switch and first live - impacting the 110kV bus, white smoke emerged between the PT compartment and control cabinet.Within
Felix Spark
07/08/2025
Operation Method for PT Resonance in 500kV GIS Switching Station
Operation Method for PT Resonance in 500kV GIS Switching Station
1. Causes of ResonanceA 500kV GIS switching station is designed following the principle of “primary equipment intelligence and secondary equipment networking”. The PT high - voltage side has no disconnector and is directly connected to the bus GIS. Through the analysis of fault recording diagrams, when the 5021 circuit breaker opens, the fracture capacitance and PT form a series circuit. Moreover, the bus voltage, after being paralleled by the PT inductance, shows inductive character
James
07/08/2025
What to Pay Attention to When Selecting and Installing GIS Current Transformers?
What to Pay Attention to When Selecting and Installing GIS Current Transformers?
Hi everyone, I'm James, and I've been working with current transformers (CTs) for 10 years. Today, I’ll talk about what you need to watch out for when selecting and installing GIS current transformers.Part 1: Key Considerations During Selection1. Accuracy ClassProtection-grade CTs: Used for relay protection — focus on overload capacity and transient response.Metering-grade CTs: Used for billing purposes — require high accuracy, usually 0.2S or 0.5S class.2. Rated Primary Curren