• Indoor vacuum circuit breaker Generator circuit breaker up to 63kA and 15 kV
Indoor vacuum circuit breaker Generator circuit breaker up to 63kA and 15 kV
discuss personally
Model
VD4G-25
Basic info
Brand ABB
Model NO. VD4G generator circuit breaker Small footprint, full protection for generator applications
Rated voltage 15kV
Rated normal current 1250A
Rated frequency 50/60Hz
Series VD4G
Product Detail

Description:

ABB offers its new vacuumgenerator circuit breakers at 15 kV,4000 A, 63 kA in accordance to thenew Dual Logo IEEE/IEC 62271-37-013 standard to satisfy yourbusiness needs in power generation applications.

Features:

Protect your assets

  • Use a solution completely inaccordance with the latest global standards - IEC as well as IEEE

  • Count on a generator circuit breakersuitable for all highly demanding conditions, including out-of-phase condition and island mode

  • Be safe thanks to a completely testedsolution for DC-component up to130%, so no need to add any time delay in the protection

Maximize your output

  • Experience the easy installation/integration of VD4G, thanks to itsinterfaces and dimensions equivalentto the standard version VD4

  • Accelerate your projects with theoutstanding technical support grantedby our Field Application Engineeringm team

Optimize your investment

  • Choose ratings that fit your needs from 25/16 kA @ 15 kV to 63/50 kA @ 15 kV

  • Take advantage of using the samecompact switchgear setup like inpower distribution systems

Technical characteristics:

Standards IEEE/IEC 62271-37- 013

 

Know your supplier
ABB
As an authorized distributor of ABB products, we take great pride in our partnership.
Main Categories
High voltage/Low voltage
Business Type
Sales
Highest Annual Export (USD)
$580000000
Professional Experience
11 years
Workplace
20000m²
占位
占位
Documents
Public.
VD4G generator circuit breaker Small footprint, full protection for generator applications
Manual English
PDF
FAQ
Q: What is a generator circuit breaker?
A: A generator circuit breaker (GCB) is a specialized switchgear device used in power generation systems to safely connect or disconnect a generator from the electrical grid or load. It is designed to interrupt high fault currents, protect the generator from overloads, short circuits, and other electrical faults, and ensure reliable operation during normal and abnormal conditions.
Related Knowledges
Research and Application of Prefabricated Enclosure Structure for High-Voltage Compartments in Substations
Research and Application of Prefabricated Enclosure Structure for High-Voltage Compartments in Substations
The economic development demands higher efficiency in substation construction, giving rise to prefabricated cabin substation technology. With modular design, equipment wiring, commissioning, and prefabrication are completed in factories, requiring only "building-block" assembly on-site. Take the 10kV prefabricated high-voltage room as an example: equipment and cabin are installed in the factory, with on-site work limited to busbar and cabin assembly. The main transformer incoming line connects v
Echo
06/14/2025
Modular Intelligent Substation - Prefabricated Secondary Switchgear Integration Assembly
Modular Intelligent Substation - Prefabricated Secondary Switchgear Integration Assembly
With the development of the national economy and society, the requirements for the quality and craftsmanship of power grid projects have become increasingly stringent. The need to improve the construction progress and quality of substations has created opportunities for the promotion of prefabricated cabin - type intelligent substations. The traditional on - site wiring and commissioning of secondary substation equipment involve a large amount of work. Moreover, on - site construction has to wai
Echo
06/13/2025
Application of Pre-integrated Prefabricated Substations in Renewable Energy Sector
Application of Pre-integrated Prefabricated Substations in Renewable Energy Sector
Against the backdrop of profound changes in the global energy landscape and the booming development of the new energy industry, the construction mode of traditional substations struggles to meet the rapid deployment needs of new energy projects. The modular intelligent prefabricated cabin substation, leveraging its innovative advantages, has become a key direction for optimizing the new energy power system. In - depth exploration of its technical principles, industry adaptability, and applicatio
Echo
06/13/2025
Research on Reliability Enhancement Scheme Implementation for Modular Intelligent Prefabricated Substations
Research on Reliability Enhancement Scheme Implementation for Modular Intelligent Prefabricated Substations
1 Implementation Strategies for the Scheme1.1 Deepen Survey and ResearchBefore constructing prefabricated cabin - type substations, it is necessary to conduct detailed surveys of local working conditions, clarify the construction scale and objectives, evaluate existing power facilities, plan projects, make up for infrastructure shortcomings, and adjust the construction rhythm. Meanwhile, control costs to avoid project suspension.1.2 Strengthen Structural ConstructionDuring promotion, multi - dim
Echo
06/13/2025
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
The secondary equipment area of conventional substations uses reinforced concrete or prefabricated steel structures, facing issues like long construction cycles, unreasonable functional zone design, strict environmental assessments, dust, noise, and disturbances. Primary and secondary equipment can only be installed after civil works and decoration, lowering construction efficiency.Prefabricated cabin substations integrate modularity, intelligence, and cost - effectiveness, boasting green, energ
Dyson
06/13/2025
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Under global climate diversity, alpine power construction faces technical and environmental challenges. Extreme climates, complex geology, and long - term low winter temperatures, along with ice, snow, and storms, strain electrical equipment stability and power facility construction (schedule, cost, maintenance). Traditional on - site substations, with long construction and poor adaptability, can’t meet alpine regions’ fast, stable power needs.Prefabricated cabin substations, as modu
Echo
06/13/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放