• Electric arc furnace transformer(distribution transformer)
Electric arc furnace transformer(distribution transformer)
discuss personally
Model
SFS11-220
Basic info
Brand Vziman
Model NO. Electric arc furnace transformer
Voltage grade 220KV
Series electric arc furnace transformer
Product Detail

Description:

  • The electric arc furnace transformer is one of the most representative types of the electric furnace transformer,It is also more frequent and intense than other kinds of transformers that the working short circuit and the harmonic shock are subjected to operation.Therefore, high requirements have been put forward for the electric arc furnace transformer in the design calculation, the structure form, the manufacturing process and the test.

  •  For example, the multi step lap core structure, inclined slot hole free binding structure, and strictly control the cutting burr, and adopts advanced core stacked flip Taiwan, pre stack yoke process measures, and fully guarantee the characteristics of cold rolled grain oriented silicon steel sheet, effectively reduce the no-load loss of the transformer.The low voltage winding impregnation process measures, enhance its stability, transformer suit process, based on the strip adjustment, ensure winding and core and winding and winding "zero tolerance" suit, in order to enhance the mechanical strength of the winding and the ability to withstand short circuit.The body is completed in a completely closed constant temperature and constant pressure cleaning room to meet the cleaning requirements and constant temperature requirements of the 220kV grade products and ensure the cleanliness and dryness of the body. At the same time, the imported kerosene steam phase drying equipment is used to make the cleanliness of the product better.The lower bracket of the lower part of the body and the upper press board all adopt the high mechanical and electrical properties of the electrotechnical laminated board. Steel clamps and pressing steel nails have sufficient strength to choose jacket pulp insulation pressure screw bowl, and reasonable layout of the support block, a stay, the pressure screw position, the winding force relative balance, improve the stability of the body.The body adopts the whole set of constant pressure drying technology to shorten the assembly time of the body. To ensure that the center of each winding is the same, so that all the windings are subjected to uniform force, thus improving the capacity of each winding to withstand short circuit.Besides, the six direction positioning measures are adopted for the body and the oil tank and the box cover to ensure the stability of the transformer in the transportation process, so that the field can be directly positioned, and the structure without suspending core is realized, which provides great convenience for on-site installation.

  •  After the whole transformer assembly is completed, the leakage point is checked through the oil pressure test, and all the leakage points are eliminated before the transformer goes out, so as to ensure that the field will not leak. And the transformer is tested in accordance with the national standard, so that every transformer in the factory is the best.

  •  Our company is the exclusive manufacturer that designs the transformer with 66kV and above electric arc furnace at the same time, and it can be designed as the three side interrupting and direct descending electric arc furnace transformer.The structure of products is the main advantage of electric arc furnace in order to solve the frequent power outages, circuit breaker short life, the operation of electric transformer in a side power case, reduces operation times of high voltage circuit breaker, reduces the operation cost because of the high voltage circuit breaker caused by frequent replacement of expensive, improved steelmaking the production efficiency of the system.

What is an electric arc furnace transformer?

Basic Concepts

  • Electric Arc Furnace: A device that utilizes the high temperature generated by electric arcs to melt metals. It is widely used in industries such as iron and steel, and non-ferrous metal smelting.

  • Electric Arc Furnace Transformer: A transformer specifically designed to supply power to electric arc furnaces. It can provide high current and high voltage and withstand frequent impact loads.

Working Principles

  • Arc Generation: The electric arc furnace generates high temperatures through the arcs between the electrodes and the metal raw materials, causing the metal raw materials to melt.

  • High Current Output: The electric arc furnace transformer provides a high current output to meet the high current requirements of the electric arc furnace.

  • Voltage Regulation Function: The electric arc furnace transformer is usually equipped with a voltage regulation device, which can adjust the output voltage according to the working state of the electric arc furnace to optimize the smelting process.

  • Impact Loads: The electric arc furnace will generate frequent impact loads during the working process, and the electric arc furnace transformer must be able to withstand these impact loads.


Know your supplier
Vziman
Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150000000
Professional Experience
3 years
Workplace
10000m²
占位
占位
Related Products
Related Knowledges
The design of the three-purpose grounding transformer
The design of the three-purpose grounding transformer
Underground Power Cable Transmission LinesDirect - buried power cable lines have large ground - distributed capacitance, causing high single - phase - to - ground short - circuit capacitive current. For 10 kV lines, if this current exceeds 10 A, arcs hardly self - extinguish, risking arc overvoltage and endangering line equipment. Arc extinction is thus necessary. With a Dyn - connected main transformer, an arc - suppression coil on the secondary neutral point suffices. For Yd - connected ones,
Dyson
06/12/2025
Failure Analysis and Design Optimization of Conventional Grounding Transformers
Failure Analysis and Design Optimization of Conventional Grounding Transformers
I. Core Cause of Damage: Electrodynamic Impact (Complying with GB/T 1094.5 / IEC 60076-5)The direct cause of high-voltage winding end collapse is the instantaneous electrodynamic impact induced by short-circuit current. When a single-phase grounding fault occurs in the system (such as lightning overvoltage, insulation breakdown, etc.), the grounding transformer, as the fault current path, withstands high-amplitude and steep-rise-rate short-circuit currents. According to Ampère's force law
Felix Spark
06/12/2025
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
1 Theoretical AnalysisIn distribution networks, grounding transformers serve two key roles: powering low - voltage loads and connecting arc - suppression coils at neutrals for grounding protection. Grounding faults, the most common distribution network fault, heavily impact transformers’ operating characteristics, causing sharp changes in electromagnetic parameters and status.To study transformers’ dynamic behaviors under single - phase grounding faults, build this model: Assume a tr
Felix Spark
06/12/2025
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
1 Classification of Neutral Grounding Methods for Solar Photovoltaic Power StationsInfluenced by differences in voltage levels and grid structures across regions, the neutral grounding methods of power systems are mainly categorized into non-effective grounding and effective grounding. Non-effective grounding includes neutral grounding via arc suppression coils and neutral ungrounded systems, while effective grounding comprises neutral solid grounding and neutral grounding via resistors. The sel
Dyson
06/12/2025
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
In a neutral-insulated three-phase power system, an earthing transformer provides an artificial neutral point, which can be solidly earthed or earthed via reactors/arc suppression coils. The ZNyn11 connection is typical, where zero-sequence magnetomotive forces in the inner/outer half-windings of the same core column cancel out, balancing fault currents in series windings and minimizing zero-sequence leakage flux/impedance.Zero-sequence impedance is critical: it determines fault current magnitud
Dyson
06/12/2025
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
The neutral grounding mode refers to the connection between the power system neutral point and ground. In China's 35 kV and below systems, common methods include ungrounded neutral, arc-suppression coil grounding, and small-resistance grounding. The ungrounded mode is widely used as it allows short-term operation during single-phase grounding faults, while small-resistance grounding has become mainstream for its fast fault removal and overvoltage limitation. Many substations install grounding tr
Felix Spark
06/12/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放