• DS6B 126kV 145kV 252kV 420kV 550kV High voltage disconnect switch
DS6B 126kV 145kV 252kV 420kV 550kV High voltage disconnect switch
discuss personally
Model
DS6B-550D/4000-63
DS6B-420D/4000-63
DS5A-252/5000-63
DS6B-252D/4000-63
DS6B-252D/3150-50
DS6B-252D/2000-40
DS6B-145D/3150-50
DS6B-145D/2000-40
DS6B-126D/3150-50
DS6B-126D/2000-50
Basic info
Brand ROCKWILL
Model NO. DS6B 126kV 145kV 252kV 420kV 550kV High voltage disconnect switch
Rated voltage 550kV
Rated normal current 4000A
Rated frequency 50/60Hz
Rated peak value withstand current 160kA
Rated short-time withstand current 63kA
Series DS6B
Product Detail

Product introduction:

DSDS6B Switch Disconnector is a kind of outdoor HV electricity transmission equipment’s at three-phase AC frequency of 50Hz/60Hz. It is used for breaking or connecting HV lines under no loads so that these lines can be changed and connected and the way the electricity runs is changed, In addition, it can be used to exercise safe electrical insulation for such HV electric

apparatuses as bus and breaker. The switch can open and close inductance/capacitance current and is able to open and close the bus to switch current.

This product is of the single-post bi-arm vertical telescope type (scissor-type) and suitable for the bus's Switch Disconnector. It can be laid out directly under the bus, thus occupying a small area. It’s effect of saving energy can be prominent at the substation where double bus lines are accompanied by the bypass bus.

The Switch Disconnector is accompanied by a JW10 earthing switch which will be used for the bus grounding at the lower layer, The grounding of the bus line at the upper layer requires the use of an independent earthing switch. 363kV and 550Kv Switch Disconnector and earthing switch are equipped with the SRCJ8 motor actuator for the single pole operation. Meanwhile, the tri-pole linkage can be achieved. The 126kV and 252kV Switch Disconnector adopt SRCJ3 motor-based actuator to realize the tri-pole linkage. The earthing switch adopts SRCS manual actuator to actualize tri-pole linkage.

This Switch Disconnector has passed the verification by the review procedure organized by China Machinery industry federation that the product structure and performance satisfy the requirements on perfection, and product's performance indices have reached the internally level of the same kinds of products

DS6B Switch Disconnector comprises three single poles and actuator. Each single pole is made of a base, post insulator, operating insulator and conducive part., The conductive pat includes the gear box and foldable conductive am fixed on the top of the post insulator, and the fixed contact hanging on the overload bus.

The actuator dives the operating insulator, and through the four link lever-driven scissor-type conductive arm, lift and lower the insulator to tighten or separate the moving contact and fixed contact on the directly overhead bus line, to open or close the Switch Disconnector. After the closing, a vertical insulating break will be formed.

Main characteristic:

  • Superior conductance system; With open structure, conductor is laid out in the middle of the transmission base while the main rod and reverse connecting rod are installed outside. Balancing spring is sealed with aluminum cover and transmission parts needing debugging are exposed for easy installation and debugging. dust prevention. Add a dustcover to bearing and adopt seal structure externally.
  • Contact forceps can cover a large area of rated contact, This product is in the double arm telescopic (scissor-type) structure. The forceps of the moving contact cover a large area of rated contact, particularly applicable to soft bus line, and also to hard bus line.
  • Open gear box, which has a good visibility, is convenient for installation, debugging and maintenance. The main crank arm is combined with operating flange to reduce he transmission link and the height of transmission base, which can improve the transmission efficiency and reliability. The rotation shat is designed as double bearing structure so that the transmission is flexible and reliable.
  • Structural design: the separation of machines from power. The design concept is the separation of machines from power, that is, the conductive elements, springs and mechanic driving elements are mutually isolated to prevent current from passing through springs and mechanical driving elements. in this way, the stability of the driving elements can be enhanced.
  • Provide one key sequential control "double confirmation" function expansion.

Main technical parameters:

Order notice 

Product model, rated voltage, rated current, rated short-lime withstand current and creepage distance must be specified at the goods-ordering time;

It must be decided whether a earthing switch should be attached to the Switch Disconnector;it must be decided whether the upper bus line of the Switch Disconnector is soft or hard.

Additionally, the external diameter of the tubular busbar shall be specified;

It must be decided whether the Switch Disconnector is arranged in cross-over or parallel form;

The actuator's model and name, motor's voltage, control voltage and the number of contacts for auxiliary switch

 

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Coordination of Reclosers and Sectionalizers in Distribution Networks
Coordination of Reclosers and Sectionalizers in Distribution Networks
Coordination of Reclosers and Sectionalizers in Distribution NetworksAutomatic reclosers and automatic sectionalizers (reclosers and sectionalizers for short) are relatively complete and highly reliable automated devices. They can not only reliably and promptly eliminate transient faults but also minimize the power outage range caused by permanent faults. Since reclosers and sectionalizers are used in distribution networks, they can selectively and effectively eliminate transient faults to preve
Echo
06/04/2025
What does the recloser testing process in Nigeria involve?
What does the recloser testing process in Nigeria involve?
The testing of reclosers in Nigeria is a rigorous, multi-stage process designed to ensure compliance with local regulations, adaptability to harsh environmental conditions, and reliable operation across diverse grid landscapes. Below is an in-depth exploration of the key testing phases and their technical implications:1. Regulatory Compliance: SONCAP Certification and NERC StandardsReclosers entering Nigeria’s market must first navigate mandatory regulatory hurdles. SONCAP certification in
Oliver Watts
06/04/2025
What are the key considerations for recloser selection in Nigeria?
What are the key considerations for recloser selection in Nigeria?
When selecting reclosers for power distribution networks in Nigeria, several critical factors must be addressed to ensure reliable, efficient, and compliant operation. Here's a breakdown of key considerations:1. Voltage Compatibility: 11kV StandardsNigeria’s distribution grid widely operates at the 11kV voltage level. Reclosers must be rated for 11kV to seamlessly integrate into the network. This ensures they can handle the system’s voltage demands, whether in urban, rural, or indust
James
06/04/2025
How does the merger device achieve distribution network feeder automation?
How does the merger device achieve distribution network feeder automation?
AC High - Voltage Automatic Recloser (Recloser for Short in This Article)The AC high - voltage automatic recloser (referred to as the recloser for short in this article) is a high - voltage switchgear with self - control (it has the functions of fault current detection, operation sequence control and execution by itself, without the need for additional relay protection and operation devices) and protection functions. It can automatically detect the current and voltage passing through the main ci
Echo
06/04/2025
Short Circuit Ratio of a Synchronous Machine
Short Circuit Ratio of a Synchronous Machine
The Short Circuit Ratio (SCR) of a Synchronous MachineThe Short Circuit Ratio (SCR) of a synchronous machine is defined as the ratio of the field current needed to generate rated voltage under open-circuit conditions to the field current required to sustain rated armature current during a short-circuit condition. For a three-phase synchronous machine, the SCR can be derived from its Open-Circuit Characteristic (O.C.C) at rated speed and Short-Circuit Characteristic (S.C.C), as illustrated in the
Edwiin
06/04/2025
Fault Analysis and Remedial Strategies for Reclosers in Vietnam's 20kV Coastal Grid
Fault Analysis and Remedial Strategies for Reclosers in Vietnam's 20kV Coastal Grid
1. IntroductionIn Vietnam's coastal regions, 20kV reclosers play a critical role in maintaining power supply reliability amid harsh environmental conditions. These devices, compliant with IEC 62271-111 and Vietnam's national standard TCVN, are frequently exposed to salt fog, high humidity, and typhoons, necessitating robust fault management strategies. This article explores typical malfunctions of IP67-rated reclosers in Vietnam and proposes integrated solutions to enhance grid resilience.2. Env
Felix Spark
06/03/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放