• DS5A 40.5kV 72.5kV 126kV High voltage disconnect switch
DS5A 40.5kV 72.5kV 126kV High voltage disconnect switch
discuss personally
Model
DS5A-126/3150-50
DS5A-126/2500-50
DS5A-126/2000-50
DS5A-126/1250-50
DS5A-72.5/4000-40
DS5A-72.5/3150-40
DS5A-72.5/2500-40
DS5A-72.5/2000-40
DS5A-72.5/1250-40
DS5A-40.5/4000-20
DS5A-40.5/2500-20
DS5A-40.5/2000-20
DS5A-40.5/1250-20
DS5A-40.5/630-20
Basic info
Brand ROCKWILL
Model NO. DS5A 40.5kV 72.5kV 126kV High voltage disconnect switch
Rated voltage 126kV
Rated normal current 3150A
Rated frequency 50/60Hz
Rated peak value withstand current 125kA
Rated short-time withstand current 50kA
Series DS5A
Product Detail

Product introduction:

DS5A Switch Disconnector Is a kind of outdoor HV electricity transmission equipment’s al three-phase AC frequency of 50Hz/60Hz. It Is used for breaking or connecting HV lines under no loads so that the power lines can be changed and connected and the way the electricity runs is changed. In addition it can be used to exercise safe eleclrica.1 insulation for such HV electric apparatuses as bus and break.

This product has two posts with horizontal open breaks. It Is open able In the middle and accessible to the grounding switch on one side or two sides. 90°drive's isolating switch and grounding switches adopt cs11 manual operating mechanism to execute the tri-pole linkage;180°drive's isolating switch adopts CS11 manual operating mechanism or CS14g manual to execute the tri-pole linkage; the grounding Switch adopts CS11 manual actuator to realize the tri-pole linkage.

DS5A Switch Disconnector comprises three single poles and actuator. Each single pole is made of a base, post insulator and conductive part. Two rotating post insulators are installed at a base with two insulators forming an angle of 50° and arranged in V shape. The contact finger arms and contact head arms of the conductive knife switch are separately fixed onto the end of the Insulating post.

The actuator drives one side of the insulating post to revolve, and drives the other side of the insulating post to rotate reversely by 90° through the angular wheel or link lever, so that the knife switch will be in circumgyration to realize the opening and closing of the Switch Disconnector. A horizontal insulating open break will appear at the closing moment.

Main characteristic:

  • The conductive arm made of rectangular Al-alloy pipes is characterized by high strength, light, weigh, large radiation area and strong resistance against corruption.
  • DS5A adopts particular copper alloy to develop the self-contained contact. The contact point is tightened by the elastic force of the contact itself. The contact spring is eliminated to avoid possible drop of the contact in gripping force due to the spring's corrosion and shunting, possible heating and annealing, possible increment in contact resistance, and possible vicious cycle of the growing heat or the contact The contact is made of curved copper plate, forming a large connection area with the conductive arm. In the opening and dosing processes, there is a short trip of friction between the contact and the finger and the required operating force is small. The conductive part has been acknowledged by the Chinese competent authority as a new and practical patent.(Patent No.: 2103 2 20022.6)
  • The rotating parts of the Switch Disconnector are designed to be free of maintenance. The rotating base is designed into a closure structure which denies the access of moisture, dust and harmful gases so that the low-temperature lubricating cream within the bearing will not run off or harden. Within the bearing base are thrust ball bearing and radial ball bearing, both of which will share the gravity and horizontal component of the Switch Disconnector so that the operating torque will not increase after the long-term operation of the disconnect switch
  • The mechanical interlock between the primary switch and earthing switch is directly installed onto the principal axis of the primary switch and the revolution axis of the earthing switch. The interlock Is direct and reliable, eliminating the structurally complex gearbox. It also facilitates easy adjustment In the field erection and avoids the corrosion of the gear box.
  • Provide one-key sequential control "double confim1ation" function expansion

Main technical parameters:

GW5A-parameters.png

Order notice :

Product model, current, rated short-time withstand current and creepage distance must be specified at the goods-ordering time;

The Switch Disconnector offers several options of grounding (no, left, right, both left and right). Unless otherwise specified, the goods suppled will be considered as providing the option of right grounding;

The operating mechanism, voltage and the number of contacts for auxiliary switch;

Methods of installation: horizontal installation, installation by the iodination of 25",side installation. Unless otherwise specified, the horizontal installation will be taken as default;

Specify the type of power and voltage degree for the electromagnetic lock of the actuator.

 

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Synchronizing Power and Torque Coefficient
Synchronizing Power and Torque Coefficient
Definition of Synchronizing PowerSynchronizing power, denoted as Psyn, is defined as the variation in synchronous powerP with respect to changes in the load angle δ. Also referred to as thestiffness of coupling,stability factor, orrigidity factor, it quantifies a synchronous machine’s (generator or motor) inherent tendency to maintain synchronism when connected to infinite busbars.Principle of Synchronism MaintenanceConsider a synchronous generator transmitting a steady power Pa at a
Edwiin
06/04/2025
Coordination of Reclosers and Sectionalizers in Distribution Networks
Coordination of Reclosers and Sectionalizers in Distribution Networks
Coordination of Reclosers and Sectionalizers in Distribution NetworksAutomatic reclosers and automatic sectionalizers (reclosers and sectionalizers for short) are relatively complete and highly reliable automated devices. They can not only reliably and promptly eliminate transient faults but also minimize the power outage range caused by permanent faults. Since reclosers and sectionalizers are used in distribution networks, they can selectively and effectively eliminate transient faults to preve
Echo
06/04/2025
What does the recloser testing process in Nigeria involve?
What does the recloser testing process in Nigeria involve?
The testing of reclosers in Nigeria is a rigorous, multi-stage process designed to ensure compliance with local regulations, adaptability to harsh environmental conditions, and reliable operation across diverse grid landscapes. Below is an in-depth exploration of the key testing phases and their technical implications:1. Regulatory Compliance: SONCAP Certification and NERC StandardsReclosers entering Nigeria’s market must first navigate mandatory regulatory hurdles. SONCAP certification in
Oliver Watts
06/04/2025
What are the key considerations for recloser selection in Nigeria?
What are the key considerations for recloser selection in Nigeria?
When selecting reclosers for power distribution networks in Nigeria, several critical factors must be addressed to ensure reliable, efficient, and compliant operation. Here's a breakdown of key considerations:1. Voltage Compatibility: 11kV StandardsNigeria’s distribution grid widely operates at the 11kV voltage level. Reclosers must be rated for 11kV to seamlessly integrate into the network. This ensures they can handle the system’s voltage demands, whether in urban, rural, or indust
James
06/04/2025
How does the merger device achieve distribution network feeder automation?
How does the merger device achieve distribution network feeder automation?
AC High - Voltage Automatic Recloser (Recloser for Short in This Article)The AC high - voltage automatic recloser (referred to as the recloser for short in this article) is a high - voltage switchgear with self - control (it has the functions of fault current detection, operation sequence control and execution by itself, without the need for additional relay protection and operation devices) and protection functions. It can automatically detect the current and voltage passing through the main ci
Echo
06/04/2025
Short Circuit Ratio of a Synchronous Machine
Short Circuit Ratio of a Synchronous Machine
The Short Circuit Ratio (SCR) of a Synchronous MachineThe Short Circuit Ratio (SCR) of a synchronous machine is defined as the ratio of the field current needed to generate rated voltage under open-circuit conditions to the field current required to sustain rated armature current during a short-circuit condition. For a three-phase synchronous machine, the SCR can be derived from its Open-Circuit Characteristic (O.C.C) at rated speed and Short-Circuit Characteristic (S.C.C), as illustrated in the
Edwiin
06/04/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放