• DS22B 126kV 145kV 252kV 363kV 420kV 550kV High voltage disconnect switch
DS22B 126kV 145kV 252kV 363kV 420kV 550kV High voltage disconnect switch
discuss personally
Model
DS22B-550D/5000-63
DS22B-550D/4000-63
DS22B-420D/3150-63
DS22B-363D/5000-63
DS22B-363D/4000-63
DS22B-252D/5000-63
DS22B-252D/4000-63
DS22B-252D/3150-50
DS22B-252D/2000-50
DS22B-145D/2500-50
DS22B-126D/4000-50
DS22B-126D/3150-50
DS22B-126D/2000-50
Basic info
Brand ROCKWILL
Model NO. DS22B 126kV 145kV 252kV 363kV 420kV 550kV High voltage disconnect switch
Rated voltage 550kV
Rated normal current 5000A
Rated frequency 50/60Hz
Rated peak value withstand current 160kA
Rated short-time withstand current 63kA
Series DS22B
Product Detail

Product introduction

DS22B Switch Disconnector is a kind of outdoor HV electricity transmission equipment at three-phase AC frequency of 50Hz/60Hz. it is used for breaking or connecting HV lines under no loads so that these lines can be changed and connected and the way he electricity runs is changed, in addition, it can be used to exercise safe electrical insulation for such HV electric apparatuses as bus and breaker. The switch can open and close inductance/capacitance current and is able to open and close the bus to switch current.

This product is in the single-post single arm vertical telescopic structure. The contact is of the forceps-type, Vertical insulating breaks will be formed after the opening. The product can be used as an disconnect switch for bus. it is directly installed directly under the bus and only occupies a small space. JW10 earthing switch can be attached for grounding the bus at the lower layer, The grounding for the bus at the upper layer requires an independent earthing switch. 363kV and 550kV switch Disconnector and earthing switch are equipped with the SRCJ2 motor actuator for the single pole operation, Meanwhile, the tre-pole linkage can be achieved, The 126kV and 252kV isolating switches adopt SRCJ7 and SRCJ3 motor-based actuators to realize the tri-pole linkage. The grounding switch adopts CS11 and SRCS manual actuators to actualize tri-pole linkage.

This switch Disconnector has passed the verification by the review procedure organized by China Machinery industry federation that the product structure and performance satisfy the requirements on perfection, and product's performance indices have reached the internal level of the same kinds of products.

DS22B switch Disconnector comprises three single poles and actuator, Each single pole is made of a base, post insulator operating insulator and conductive part. The conductive part includes the gear box and foldable conductive arm fixed on the top of the post insulator, and the fixed contact hanging on the overload bus.

The actuator drives the operating insulator, and through the ink lever-driven conducive arm, if and lower the insulator to tighten or separate the moving contact and fixed contact on the directly overhead bus line to open or close the disconnect switch. After the opening, a vertical insulating break will be formed.

Main characteristic

  • State-of-art structure: The switch Disconnector is in the single-arm, foldable and telescopic structure, The driving elements and balancing springs are sealed within the conductive tube to reduce their adverse effects on natural environment and render the appearance compact and simple; The drive base adopts a link lever, Compared with angular wheels, the product is simpler and easier to adjust.
  • Superior conductance system: The conductive part made of Al-alloy of high conductance rate is characteristic of good conductance, high mechanical strength, light weight and strong corrosion resistance; The current will pass through the foldable area of the conductive arm via soft connection (without recourse to any movable contacts) to ensure reliable conductance, few maintenance, no examination, and long-term reliable operation.
  • Stable static contact structure:The hanging fixed contact is fixed with a pure alloy conductor ring to realize high degree of current flow capacity, The fixed contacts are hanged and fixed with the steel wires in the triangle shape to ensure the adjustment friendliness, stability and the reduction in vertical displacement.
  • Provide one-key sequential control "double confirmation" function expansion.
  • Unique forceps-type contact: The contact is of the forceps-type. The moving knife switch will be additionally accompanied by the extremal spring to ensure the constant contact pressure. The lower end of the knife switch is in sot connection with the base (without recourse to any movable contacts) to ensure reliable conductance and avoid the over-heating from poor contact The base for the moving contact is welded with the upper guide tube to prevent the water from penetrant into the milling mouth of the clamping head, The connection between the base of the contact and the draw rod is uniquely sealed to ensure no water penetration or accumulation at the base for the movable contact, In this way, the rust of parts within the conducive arm or the obstacles to the movement of the contact as a result of the ice coating in winter will be eliminated, and the failure of the disconnect switch to be opened or closed will also be avoided; The arc contact can be mounted onto the movable and fixed contacts to enable the switch Disconnector to switch current capacitive and inductive current by opening and closing bus line.
  • Simple and superior earthing switch: 363kV and above earthing switch is in the single-arm standing and openable structure, with the structurally simple plug-type contact. The conductive rod for grounding will move in two steps at the moments of opening and closing. At the moment of closing, the conductive rod will rotate vertically and rise up lo the fixed contact, and then automatically plug itself into the star-shaped contact. By doing so, the contact will be made reliable and be able to sustain the heavy short-circuit current.

Main technical parameters

Order notice 

Product model, rated voltage, rated current, rated short-time withstand current and creepage distance must be specified at the goods-ordering time;

It can be decided whether a earthing switch should be attached to the switch Disconnector;

It must be decided whether the upper bus line of the switch Disconnector is soft or hard. Additionally, the external diameter of the tubular busbar shall be specified;

It must be decided whether the disconnect switch is arranged in cross-over or parallel form;

The actuator's model, motor's voltage, control voltage and the number of contacts for auxiliary switch.

 

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Modular Intelligent Substation - Prefabricated Secondary Switchgear Integration Assembly
Modular Intelligent Substation - Prefabricated Secondary Switchgear Integration Assembly
With the development of the national economy and society, the requirements for the quality and craftsmanship of power grid projects have become increasingly stringent. The need to improve the construction progress and quality of substations has created opportunities for the promotion of prefabricated cabin - type intelligent substations. The traditional on - site wiring and commissioning of secondary substation equipment involve a large amount of work. Moreover, on - site construction has to wai
Echo
06/13/2025
Application of Pre-integrated Prefabricated Substations in Renewable Energy Sector
Application of Pre-integrated Prefabricated Substations in Renewable Energy Sector
Against the backdrop of profound changes in the global energy landscape and the booming development of the new energy industry, the construction mode of traditional substations struggles to meet the rapid deployment needs of new energy projects. The modular intelligent prefabricated cabin substation, leveraging its innovative advantages, has become a key direction for optimizing the new energy power system. In - depth exploration of its technical principles, industry adaptability, and applicatio
Echo
06/13/2025
Research on Reliability Enhancement Scheme Implementation for Modular Intelligent Prefabricated Substations
Research on Reliability Enhancement Scheme Implementation for Modular Intelligent Prefabricated Substations
1 Implementation Strategies for the Scheme1.1 Deepen Survey and ResearchBefore constructing prefabricated cabin - type substations, it is necessary to conduct detailed surveys of local working conditions, clarify the construction scale and objectives, evaluate existing power facilities, plan projects, make up for infrastructure shortcomings, and adjust the construction rhythm. Meanwhile, control costs to avoid project suspension.1.2 Strengthen Structural ConstructionDuring promotion, multi - dim
Echo
06/13/2025
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
The secondary equipment area of conventional substations uses reinforced concrete or prefabricated steel structures, facing issues like long construction cycles, unreasonable functional zone design, strict environmental assessments, dust, noise, and disturbances. Primary and secondary equipment can only be installed after civil works and decoration, lowering construction efficiency.Prefabricated cabin substations integrate modularity, intelligence, and cost - effectiveness, boasting green, energ
Dyson
06/13/2025
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Under global climate diversity, alpine power construction faces technical and environmental challenges. Extreme climates, complex geology, and long - term low winter temperatures, along with ice, snow, and storms, strain electrical equipment stability and power facility construction (schedule, cost, maintenance). Traditional on - site substations, with long construction and poor adaptability, can’t meet alpine regions’ fast, stable power needs.Prefabricated cabin substations, as modu
Echo
06/13/2025
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Compact substation boxes, with advantages like safe operation, high reliability, and easy maintenance, are used in urban grid construction/renovation. Structurally divided into American - style (high - cost, noisy, low - efficiency, gradually phased out) and European - style (large - sized but more advantages, still popular).To address their pros/cons, ring - network prefabricated ones were developed.I. Basic Materials for Prefabricated Compact Substation BoxesMaterials need hardness, strength,
Echo
06/13/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放