• Dry isolating transformer
Dry isolating transformer
discuss personally
Model
IS11-20/380
Basic info
Brand Vziman
Model NO. Dry isolating transformer
Rated capacity 20KVA
Voltage grade 380V
Series Isolating Transformer
Product Detail

Product overview:

  • Dry isolating transformer is produced by Wone  with high quality materials and advanced technology. It has the advantages of moistureproof and convenient maintenance. It is mainly used in various power supply places with AC 50/60Hz and voltage not exceeding 660V.

  • Actual measurement is better than GB and IEC standards, CB CCC KEMA certification.

  • High reliability of operation verification in more than 50 countries and regions around the world.

  • Mainly used in various high and low voltage complete sets of electrical, precision machine tools, UPS, electroplating, lighting, heating, communication, chemical industry equipment control power, power supply.

  • Products are mainly exported to central Asia, Southeast Asia, the Middle East, Africa, South America and other markets and regions.

Product advantages:
Leading technology

  •  Copper foil winding technology, high quality A class insulation material insulation.

  •  Small magnetic leakage, high mechanical strength, strong short circuit resistance.

  •  Iron core 45° full oblique joint step laminated structure.

The iron core:

  • The core material is high quality cold rolled grain oriented silicon steel sheet with mineral oxide insulation (from  Baowu Steel Group, China).

  • Minimize loss level, no-load current and noise by controlling the cutting and stacking process of silicon steel sheet.

  • The iron core is specially reinforced to ensure the transformer structure is firm during normal operation and transportation.

winding:

  • Wrapped with high quality copper foil (customizable aluminum foil), excellent insulation resistancem.

  • High quality material.

  • Baowu Steel Group production of silicon steel sheet.

  • High quality anaerobic copper from China.

Ordering instructions:

  • Main transformer parameters.

  • Transformer operating environment.

  • Other customization requirements.

  • The minimum order quantity is 1 sets, worldwide delivery within 7 days.

  • Normal delivery period of 30 days, worldwide fast delivery.

What is galvanic isolation?

Transformer Isolation:

  • Principle: Electrical isolation is achieved by utilizing the magnetic coupling between the primary winding and the secondary winding of the transformer. There is no direct electrical connection between the primary winding and the secondary winding of the transformer, but energy can be transferred through the magnetic field.

  • Application: It is widely used in power adapters, medical devices, laboratory instruments, etc.

 Optocoupler Isolation:

  • Principle: Electrical isolation is realized by using an optocoupler (photoelectric coupler) to convert an electrical signal into an optical signal and then converting the optical signal back into an electrical signal. The optocoupler contains a light-emitting diode (LED) and a photosensitive element (such as a phototransistor) inside.、

  • Application: It is widely used in digital circuits, control systems, communication equipment, etc.

 Relay Isolation:

  • Principle: Electrical isolation is achieved by using the contact switches of the relay. There is no direct electrical connection between the coil circuit and the contact circuit of the relay, but signals can be transmitted through the switching action of the contacts.

  • Application: It is widely used in control systems, switching circuits, etc.

 Isolation Amplifier:

  • Principle: The input signal is isolated from the output signal by using an isolation amplifier while maintaining the amplification and transmission of the signal. The isolation amplifier usually contains isolation elements such as transformers or optocouplers inside.

  • Application: It is widely used in industrial measurement, sensor signal processing, etc.


Know your supplier
Vziman
Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150000000
Professional Experience
3 years
Workplace
10000m²
占位
占位
Related Products
Related Knowledges
The design of the three-purpose grounding transformer
The design of the three-purpose grounding transformer
Underground Power Cable Transmission LinesDirect - buried power cable lines have large ground - distributed capacitance, causing high single - phase - to - ground short - circuit capacitive current. For 10 kV lines, if this current exceeds 10 A, arcs hardly self - extinguish, risking arc overvoltage and endangering line equipment. Arc extinction is thus necessary. With a Dyn - connected main transformer, an arc - suppression coil on the secondary neutral point suffices. For Yd - connected ones,
Dyson
06/12/2025
Failure Analysis and Design Optimization of Conventional Grounding Transformers
Failure Analysis and Design Optimization of Conventional Grounding Transformers
I. Core Cause of Damage: Electrodynamic Impact (Complying with GB/T 1094.5 / IEC 60076-5)The direct cause of high-voltage winding end collapse is the instantaneous electrodynamic impact induced by short-circuit current. When a single-phase grounding fault occurs in the system (such as lightning overvoltage, insulation breakdown, etc.), the grounding transformer, as the fault current path, withstands high-amplitude and steep-rise-rate short-circuit currents. According to Ampère's force law
Felix Spark
06/12/2025
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
1 Theoretical AnalysisIn distribution networks, grounding transformers serve two key roles: powering low - voltage loads and connecting arc - suppression coils at neutrals for grounding protection. Grounding faults, the most common distribution network fault, heavily impact transformers’ operating characteristics, causing sharp changes in electromagnetic parameters and status.To study transformers’ dynamic behaviors under single - phase grounding faults, build this model: Assume a tr
Felix Spark
06/12/2025
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
1 Classification of Neutral Grounding Methods for Solar Photovoltaic Power StationsInfluenced by differences in voltage levels and grid structures across regions, the neutral grounding methods of power systems are mainly categorized into non-effective grounding and effective grounding. Non-effective grounding includes neutral grounding via arc suppression coils and neutral ungrounded systems, while effective grounding comprises neutral solid grounding and neutral grounding via resistors. The sel
Dyson
06/12/2025
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
In a neutral-insulated three-phase power system, an earthing transformer provides an artificial neutral point, which can be solidly earthed or earthed via reactors/arc suppression coils. The ZNyn11 connection is typical, where zero-sequence magnetomotive forces in the inner/outer half-windings of the same core column cancel out, balancing fault currents in series windings and minimizing zero-sequence leakage flux/impedance.Zero-sequence impedance is critical: it determines fault current magnitud
Dyson
06/12/2025
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
The neutral grounding mode refers to the connection between the power system neutral point and ground. In China's 35 kV and below systems, common methods include ungrounded neutral, arc-suppression coil grounding, and small-resistance grounding. The ungrounded mode is widely used as it allows short-term operation during single-phase grounding faults, while small-resistance grounding has become mainstream for its fast fault removal and overvoltage limitation. Many substations install grounding tr