• DLMS Electricity Meter Split Type PLC Communication
  • DLMS Electricity Meter Split Type PLC Communication
  • DLMS Electricity Meter Split Type PLC Communication
DLMS Electricity Meter Split Type PLC Communication
$90.00
Model
DM-230/5(30)-SPLIT
DM-230/5(32)-SPLIT
DM-230/5(40)-SPLIT
DM-230/5(45)-SPLIT
DM-230/5(50)-SPLIT
DM-230/5(80)-SPLIT
SEM-230/5(100)-PLC
Basic info
Brand Wone
Model NO. DLMS Electricity Meter Split Type PLC Communication
Rated voltage 230V
Rated normal current 5(30)A
Rated frequency 50Hz
Methods of Communication RS485
Series D12A067
Product Detail

Description

Electricity charging and electricity tamper has always been a focus of great concern in African countries, this three-phase four-wire meter effectively solves the problem of charging for STS prepaid meters, and has anti-tamper functions such as zero-line metering and open cover detection, which meets the pain points of power operators in African countries.

Features

  • Support load ground connection, bypass, open cover detection, influence of external magnetic field, abnormal voltage record, live&neutral wire metering.

  •  Anti-tamper when Neutral missing:when Neutral missing, the meter still can workbattery support

  • Divide into weekday timetable and weekend timetable, with 8 time period and 8 tariffs. Every timetable has a backup table for remote updating of backup timetable and configure the switching time. Meter will automatically switch the tariff table at the switching time.

  • Meter support PLC communication.

  • Open cover, magnetic field, load ground connection, reserve current, over-voltage, low-voltage, low-frequency, overload, power-fail, low remaining power, and token record.

  • Meter measures voltage, current, active power, reactive power, frequency, power factor, MD in the current month, MD of last 1 month, MD of last 2 month, the absolute value of total active energy, the absolute value of total active tariff energy, total input energy of the current month, total input energy of last 5 month, total output energy of the current month, total output energy of last 5 month, and total reactive energy.

  • Meter has 3 operation modes: STS token mode, currency prepaid mode and post-paid (traditional) mode, which can be switched.

  • And the currency mode can be divided into tariff mode and step price mode. Modes can be configured through communication.

  • Enter 20-digit token via keypad of meter or IHD, the meter display will be green Pic 1 if recharging is successful, will be red Pic 2 if is failed.

Specifications

Main
Range D12A067
Product or Componet Type Energy meter
Country of origin China
Complementary
Phase Three Phase
Type of measurement

----

Metering type

Measurement

Device Application

Energy Charge

Accuracy class Active power 1.0 
Rated Current 5(100)A

Rated Voltage

230V

Network Frequency 50Hz
Technology Type Electronic
Display Type LCD display(LCD 6+2 = 999999.99kWh)
Impulse Constant

1000imp/kWh(LED)   1000imp/kvarh

Maximum value measured 99999.99kWh
Tariff input ---
Communication port protocol DLMS/COSEM(IEC62056)
Communication port support PLC/Bluetooth
Local signalling

------

Number of inputs -------
Number of Outputs --------------
Output voltage 230V
Mounting Mode ---
Mounting Support ----
Connections - terminals

-------

Standards

IEC62052-11:2003, IEC62053-21:2003, IEC 62056-21,

IEC62055-41:2018



Environment
IP degree of protection

IP54

Relative humidity ≤75%
Ambient air temperature for operation -20…70°C
Ambient Air Temperature for Storage --30…80 °C
Operating altitude ---
Dimensions 193.8*117*58mm
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 60mm
Package 1 Width 119mm
Package 1 Length 195mm
Package 1 Weight 1.000kg



Connection Diagram


image.png


Dimensions


image.png









Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
The design of the three-purpose grounding transformer
The design of the three-purpose grounding transformer
Underground Power Cable Transmission LinesDirect - buried power cable lines have large ground - distributed capacitance, causing high single - phase - to - ground short - circuit capacitive current. For 10 kV lines, if this current exceeds 10 A, arcs hardly self - extinguish, risking arc overvoltage and endangering line equipment. Arc extinction is thus necessary. With a Dyn - connected main transformer, an arc - suppression coil on the secondary neutral point suffices. For Yd - connected ones,
Dyson
06/12/2025
Failure Analysis and Design Optimization of Conventional Grounding Transformers
Failure Analysis and Design Optimization of Conventional Grounding Transformers
I. Core Cause of Damage: Electrodynamic Impact (Complying with GB/T 1094.5 / IEC 60076-5)The direct cause of high-voltage winding end collapse is the instantaneous electrodynamic impact induced by short-circuit current. When a single-phase grounding fault occurs in the system (such as lightning overvoltage, insulation breakdown, etc.), the grounding transformer, as the fault current path, withstands high-amplitude and steep-rise-rate short-circuit currents. According to Ampère's force law
Felix Spark
06/12/2025
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
1 Theoretical AnalysisIn distribution networks, grounding transformers serve two key roles: powering low - voltage loads and connecting arc - suppression coils at neutrals for grounding protection. Grounding faults, the most common distribution network fault, heavily impact transformers’ operating characteristics, causing sharp changes in electromagnetic parameters and status.To study transformers’ dynamic behaviors under single - phase grounding faults, build this model: Assume a tr
Felix Spark
06/12/2025
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
1 Classification of Neutral Grounding Methods for Solar Photovoltaic Power StationsInfluenced by differences in voltage levels and grid structures across regions, the neutral grounding methods of power systems are mainly categorized into non-effective grounding and effective grounding. Non-effective grounding includes neutral grounding via arc suppression coils and neutral ungrounded systems, while effective grounding comprises neutral solid grounding and neutral grounding via resistors. The sel
Dyson
06/12/2025
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
In a neutral-insulated three-phase power system, an earthing transformer provides an artificial neutral point, which can be solidly earthed or earthed via reactors/arc suppression coils. The ZNyn11 connection is typical, where zero-sequence magnetomotive forces in the inner/outer half-windings of the same core column cancel out, balancing fault currents in series windings and minimizing zero-sequence leakage flux/impedance.Zero-sequence impedance is critical: it determines fault current magnitud
Dyson
06/12/2025
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
The neutral grounding mode refers to the connection between the power system neutral point and ground. In China's 35 kV and below systems, common methods include ungrounded neutral, arc-suppression coil grounding, and small-resistance grounding. The ungrounded mode is widely used as it allows short-term operation during single-phase grounding faults, while small-resistance grounding has become mainstream for its fast fault removal and overvoltage limitation. Many substations install grounding tr
Felix Spark
06/12/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放