• 5kW Single Three-phase Integrated Small Diesel Generator Set
  • 5kW Single Three-phase Integrated Small Diesel Generator Set
  • 5kW Single Three-phase Integrated Small Diesel Generator Set
  • 5kW Single Three-phase Integrated Small Diesel Generator Set
5kW Single Three-phase Integrated Small Diesel Generator Set
$5000.00
Model
DMDS6500LE
Basic info
Brand Wone
Model NO. 5kW Single Three-phase Integrated Small Diesel Generator Set
Phases Single /Three
Engine Max Output Power 6.5/3600 kW/rpm
Generator Rated Power 5.0 kW
Generator Rated Voltage 230V、230/400V
Generator Capacity 12.5L
Series Small diesel generator set
Product Detail

Description:

  • Large muffler, dynamic balance shaft, special design of low-noise unit, shell and frame with shock absorption function.

  • Large capacity fuel tank to ensure long-term continuous work.

  • Non-fuse circuit breaker provides overload protection, capacitive voltage regulator to ensure stable voltage output.

  • Durable four-wheel dragging base structure, easy to move.

Parameter:

image.png

Feature:

Single - cylinder air - cooled engine - compact structure

It is a four - stroke, direct - injection, air - cooled engine with well - designed transmission mechanism. It features light weight, small volume, and low failure rate. The high - precision fuel injection pump enables more complete combustion of fuel and saves fuel.

企业微信截图_1734333634346.png

Arbitrary switching between single - phase and three - phase — equal power output

  • The single - phase and three - phase have an equal power output of 5 kilowatts, and the dual - voltage can be switched with one key, which is convenient and fast.

  • When switched to 230V: single - phase power generation is 5KW.

  • When switched to 400V: three - phase power generation is 5KW.

企业微信截图_17343338181766.png

The open - shelf structure - convenient for maintenance

  • It uses high - quality metal pipes and has a shelf - like design. It is integrally welded, with a high safety factor and good heat dissipation performance.

  • It is convenient for maintenance and suitable for various engineering construction applications and outdoor transportation.

OTC automatic welding

  • The frame is more solid, and the joints are not easy to break.

  • It is safer and more reassuring.

企业微信截图_17343339424276.png

Standard - equipped mobile fire - wheels — convenient for movement

  • It is convenient for movement in outdoor construction. The wheels are made of nylon, which is wear - resistant and has a long service life.Contact customer service to customize brake - equipped universal wheels according to your own needs. The brake - equipped universal caster wheels can be temporarily fixed when in use and converted to a rotation mode when pushed.

企业微信截图_17343340651622.png

The all - copper - wire damping motor - high reliability

  • The damping motor has good waveform, small distortion, strong overload capacity and high reliability. Equipped with an AVR automatic voltage regulator, it stabilizes the output voltage of the generator and automatically changes the excitation current size.

企业微信截图_17343341581777.png


Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Phasor Method for Solving Parallel Circuits
Phasor Method for Solving Parallel Circuits
When dealing with parallel circuits, multiple branches are connected in parallel. Each branch contains components such as resistors, inductors, and capacitors, forming a series circuit within that branch. Each branch is first analyzed separately as a series circuit, and then the effects of all branches are combined.In circuit calculations, both the magnitude and phase angle of current and voltage are taken into account. When solving the circuit, the magnitudes and phase angles of voltages and cu
Edwiin
05/30/2025
Permanent Magnet Moving Coil or PMMC Instrument
Permanent Magnet Moving Coil or PMMC Instrument
DefinitionInstruments that utilize a permanent magnet to generate a stationary magnetic field within which a coil moves are known as Permanent Magnet Moving Coil (PMMC) instruments. They operate on the principle that torque is exerted on a moving coil situated in the magnetic field of a permanent magnet. PMMC instruments provide accurate results for direct current (DC) measurements.Construction of PMMC InstrumentThe moving coil and the permanent magnet are the key components of a PMMC instrument
Edwiin
05/30/2025
Difference Between Porcelain and Glass Insulators
Difference Between Porcelain and Glass Insulators
Key Differences Between Glass and Porcelain InsulatorsBoth porcelain and glass insulators are widely applied in power transmission and distribution to insulate overhead line conductors from supporting towers and poles. With extended service lives and suitability for high voltage ratings, their unique characteristics and properties define their distinct application scenarios.Porcelain InsulatorsPorcelain, a ceramic material, is valued for its absence of internal defects such as voids, cracks, or
Edwiin
05/30/2025
What is Static VAR Compensator (SVC)? Circuit & Operation in PF Correction
What is Static VAR Compensator (SVC)? Circuit & Operation in PF Correction
What is a Static VAR Compensator (SVC)?A Static VAR Compensator (SVC), also termed a Static Reactive Compensator, is a critical device for enhancing the power factor in electrical power systems. As a type of static reactive power compensation equipment, it injects or absorbs reactive power to maintain optimal voltage levels, ensuring stable grid operation.An integral part of the Flexible AC Transmission System (FACTS), an SVC comprises a bank of capacitors and reactors controlled by power electr
Edwiin
05/30/2025
Comparison Between Overhead & Underground Transmission Systems
Comparison Between Overhead & Underground Transmission Systems
Key Differences and Comparison Between Underground and Overhead Power Transmission & DistributionPublic SafetyIn terms of public safety, underground systems outperform overhead transmission systems. With all transmission and distribution components buried, underground setups minimize risks from obstacles and external interference. Additionally, they are less susceptible to environmental factors like wind, storms, and heavy rain, making them inherently more secure.Initial CostUnderground syst
Edwiin
05/30/2025
What is the Difference Between Shunt Reactor and Shunt Capacitor?
What is the Difference Between Shunt Reactor and Shunt Capacitor?
In an electrical power system, various devices are utilized to enhance power factor and operational efficiency. Shunt capacitors and shunt reactors represent two distinct components designed to optimize the performance of electrical grids. This article explores their key differences, beginning with an overview of their fundamental principles.Shunt CapacitorsA shunt capacitor refers to a single capacitor or a group of capacitors (termed a capacitor bank) connected in parallel to the power system.
Edwiin
05/30/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放