• 15kV MV outdoor vacuum Auto Circuit recloser
  • 15kV MV outdoor vacuum Auto Circuit recloser
15kV MV outdoor vacuum Auto Circuit recloser
$7500.00
Model
RCW-F15G/630-16
RCW-F15G/400-12.5C
RCW-F15G/1250-25C
RCW-F15G/1250-25
RCW-F15G/800-20C
RCW-F15G/800-20
RCW-F15G/400-12.5
Basic info
Brand ROCKWILL
Model NO. 15kV MV outdoor vacuum Auto Circuit recloser
Rated voltage 15kV
Rated normal current 630A
Rated short circuit breaking current 16kV
Power frequency withstand voltage 45kV/min
Rated lightning impulse voltage 120kV
manual closing No
Series RCW
Product Detail

Description:

The RCW   series automatic circuit reclosers can use on overhead distribution lines as well as distribution substation applications for allvoltage classes 11kV up to 38kV at 50/60Hz power system.  and it’s rated current can reach 1250A.The RCW   series automatic circuit reclosers integrates the functions of control, protection, measurement, communication, fault detection, on-line monitoring of closing or opening.The RCW   series vacuum recloser is mainly combined with integration terminal, current transformer, permanent magnetic actuator and it’s recloser controller.

Features:

  • Optional grades available in rated current range

  • With optional relay protection and logic for user selection

  • With optional communication protocols and I/O ports for users to choose

  • PC software for controller testing, setup, programming, updates

Parameters:

Rated maximum voltage

15KV

Rated maximum current

400A

Rated frequency

50Hz

Rated short circuit breaking current

12.5KA

Rated peak value withstand current

31.5KA

Rated 1min power frequencywithstand voltageThree-phase Epoxy resin pole

45KV

Rated lightning impulse voltage(Three-phase Epoxy resin pole)

120KV

Operation sequence

C-0.5-CO-2-CO-5-CO(Magnetic actuator)

Mechanical life

n:30000(Magnetic actuator)

Power supply and operating voltage

110/220V( Customized)

Ratio of current transformer

400/1A( Customized)

Number of voltage sensorsThree-phase Epoxy resin pole

≤6

Opening time

≤30ms(Magnetic actuator)

Closing time

≤40ms(Magnetic actuator)

Minimum creepage distance

31level4mm/kv

Minimum distance between phases

360mm

Potential transformer

110/220V( Customized)

Cable length

6,8,12m( Customized)

Cable clampThree-phase Epoxy resin pole

4-hole NEMA

Lightning arrester

≤6

Mounting type

Single / double column

With optional relay protection& logics for user choice

Instantaneous over-current protection

Timing over-current protection

Negative sequence over-current protection

Directional over-current protection(*)

Over-voltage protection./Under voltage protection

Programable protection relay curves total 10 nos ANSI/IEC curves

Cold load pickup protection TCC +Hot line tag

Earth protection EF/SEF +Zone Sequence Co-ordination

More relay functions can be customized

With optional communication protocols & I/O port for user choice

RS-232 and RS-485 ports supporting

DNP3.0 communication protocol support(*)

Modbus communication protocol is optional(*)

IEC 60870-5-101 communication protocol support

IEC 60870-5-104 communication protocol support.(*)

The recloser can communicate through GPRS(Or GSM) modem with English or Specified language (*)

With optional functions for use

Rated currents, System phase current.

Rated voltages, System phase voltage& secondary low voltage power supply voltage. Frequency, 

power(kWh), reactive power(kV arh), power factor

With optional reclosing interval for user pre-program

Reclosing times setting support

Dead time setting support

With events recording function

SOE 10000 operations record

Fault record and normal operation record

Note: (*) mean should customized by manufacturer if needed

Environmental requirement:

Maximum temperature:

+40℃

Minimum temperature:

-30℃

Monthly average humidity

                          95%

Humidity:

                          90%

Above sea level:

2500m or higher

Ambient air not apparently polluted by corrosive and flammable gas, vapor

Product show:

企业微信截图_17104644186528.png


Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Design of Remote Closing Device for Indoor Handcart High-Voltage Vacuum Circuit Breaker
Design of Remote Closing Device for Indoor Handcart High-Voltage Vacuum Circuit Breaker
The cabling and undergrounding of urban power grid lines have become an irreversible trend in distribution network construction. High-voltage switchgear, as the core equipment of the distribution system, has become the main object of daily operation and maintenance for maintenance personnel. During the equipment iteration process, the comprehensive replacement and commissioning of new equipment have a long cycle, and a type of old hand-cranked high-voltage switchgear is still in service.Due to l
Dyson
06/07/2025
Design and Development of WVT-12 Vacuum Circuit Breaker
Design and Development of WVT-12 Vacuum Circuit Breaker
I. Market and Technical ResearchSince 2003, I have been engaged in the key project of localizing WVT-12 vacuum circuit breaker technology for Anhui Longbo Company. At that time, in the 12kV voltage class, vacuum circuit breakers had occupied more than 98% of the total circuit breakers. With the advancement of power grid construction and the growth of industrial and residential electricity demand, the domestic and international markets have shown a continuous upward trend in the demand for advanc
Dyson
06/07/2025
Regarding the transformation of permanent magnet circuit breakers in the 35kV switch room of 110kV substation in Luliang Oilfield
Regarding the transformation of permanent magnet circuit breakers in the 35kV switch room of 110kV substation in Luliang Oilfield
I. Equipment Dilemmas in Freezing WintersThe 35kV switch room of the 110kV substation in Luliang Oilfield, commissioned in 2002, has always been a key area for my maintenance team. The original ZN23-40.5/1600 vacuum circuit breakers, equipped with spring operating mechanisms, posed recurring challenges during subzero winters. With over 200 components and a 12-stage mechanical linkage, the spring mechanisms suffered severe wear on sliding friction surfaces. In temperatures as low as -40°C, lu
Echo
06/07/2025
What are the contents of operation and maintenance for the VS1 indoor high-voltage vacuum circuit breaker?
What are the contents of operation and maintenance for the VS1 indoor high-voltage vacuum circuit breaker?
VS1 - Type Indoor High - Voltage Vacuum Circuit BreakerThe VS1 - type indoor high - voltage vacuum circuit breaker is an indoor device for three - phase AC 50Hz with a rated voltage of 12kV. It is used for the control and protection of electrical facilities in industrial and mining enterprises, power plants, and substations. The circuit breaker arranges the main circuit and the operating mechanism on a special - shaped frame in a front - rear manner, that is, an integral layout. This structural
Echo
06/06/2025
What are the common faults of indoor AC high-voltage vacuum circuit breakers?
What are the common faults of indoor AC high-voltage vacuum circuit breakers?
ZN63A Indoor AC High-Voltage Vacuum Circuit BreakerThe ZN63A indoor AC high-voltage vacuum circuit breaker is a three-phase AC 50 Hz, 12 kV indoor device, used for starting, stopping, controlling, and protecting high-voltage motors of 10,000-ton free forging presses. AC high-voltage vacuum circuit breakers play a critical role in enterprise production. Timely and accurate resolution of their faults to quickly restore production is essential for enterprise development. During the start/stop of hi
Felix Spark
06/06/2025
Load Frequency Control (LFC) & Turbine Governor Control (TGC) in Power System
Load Frequency Control (LFC) & Turbine Governor Control (TGC) in Power System
Brief Introduction to Thermal Generating UnitsElectricity generation relies on both renewable and non - renewable energy resources. Thermal generating units represent a conventional approach to power production. In these units, fuels such as coal, nuclear energy, natural gas, biofuel, and biogas are combusted within a boiler.The boiler of a generating unit is an extremely complex system. In its simplest conception, it can be visualized as a chamber whose walls are lined with pipes, through which
Edwiin
06/06/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放