• 344KWh Liquid Cooling ESS Solution
344KWh Liquid Cooling ESS Solution
discuss personally
Model
LC-344K2HDLA
Basic info
Brand POWERTECH
Model NO. 344KWh Liquid Cooling ESS Solution
Rated capacity 344KWh
Max discharge power 0.5P
Series Industrial&Commercial energy storage
Product Detail

Description

The liquid cooling battery cabinet integrates battery modules with a full configuration capacity of 344kWh. It is compatible with 1000V and 1500V DC battery systems, and can be widely used in various application scenarios such as generation and transmission grid, distribution grid, new energy plants.

Features

  • Full configuration capacity with 8 modules with 344kWh.

  • Liquid-cooled battery modular design, easy to system expansion.

  • Intelligent monitoring and linkage actions ensure battery system safety.

  • Integrated heating system for thermal safety and enhanced performance and reliability.

  • The turnkey system is design to enhance higher efficiency and prolong battery life.

  • Highly integrated ESS for easy transportation and flexible O&M.

  • Multiple operation modes are available, the software can be customized and upgraded.

  • Cloud-based monitoring and operation platform supports the visit of Mysql database and multiple devices.

Application

  • Discharge at time of peak demand to reduce expensive demand charge.

  • Daytime load maximizes PV power, and excess power is stored for use at night.

  • Powers a facility when the grid goes down, or application in areas without electricity.

  • Carry out arbitrage by using peak and valley electricity prices in different time periods.

  • Smooth out the intermittency of renewables by storing and dispatching when needed.

  • Supply power at a distributed location to reduce investment in the construction of the grid.

Battery date

image.png

General date

image.png

How liquid-cooled energy storage solutions work?

The core of the liquid-cooled energy storage solution lies in its efficient thermal management system. This system absorbs and transfers the heat generated during the battery's operation through a liquid (usually a water-based coolant or a special coolant), thereby keeping the battery within the optimal operating temperature range and improving the battery's performance and lifespan. The following is the specific working process:

  • Energy storage:When the power supply is sufficient, the energy storage system converts alternating current (AC) into direct current (DC) through an inverter and stores it in the battery module.Battery modules usually adopt lithium-ion battery technologies such as lithium iron phosphate (LiFePO4), ternary material (NMC), lithium cobalt oxide (LCO), etc.

  • Temperature monitoring:The battery management system (BMS) monitors the temperature of each battery cell and detects temperature changes through sensors.The BMS will send temperature data to the control system so that the cooling system can be started in time.

  • Liquid cooling:The cooling system pumps the coolant to the cooling plates or cooling channels around the battery module through pipes.
    The coolant directly contacts the battery surface or cooling plate and absorbs the heat generated during the battery's operation.

  • Heat transfer:The coolant after absorbing heat is pumped back to the cooling device (such as a heat exchanger, radiator, etc.) through pipes.
    In the cooling device, the heat is transferred to the external environment. After the coolant is cooled again, it returns to the battery module to continue circulating.

  • Energy release:When power demand increases or supply is insufficient, the stored direct current is converted into alternating current through an inverter and transmitted to the power grid or directly used by users.
    During this process, the liquid cooling system continues to monitor and manage the battery's temperature to ensure that the battery is in the optimal working state.



Know your supplier
POWERTECH
We are an electrical company that manufactures and sells high and low voltage electrical products.
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$120000000
Professional Experience
7 years
Workplace
580000m²
占位
占位
Related Knowledges
The design of the three-purpose grounding transformer
The design of the three-purpose grounding transformer
Underground Power Cable Transmission LinesDirect - buried power cable lines have large ground - distributed capacitance, causing high single - phase - to - ground short - circuit capacitive current. For 10 kV lines, if this current exceeds 10 A, arcs hardly self - extinguish, risking arc overvoltage and endangering line equipment. Arc extinction is thus necessary. With a Dyn - connected main transformer, an arc - suppression coil on the secondary neutral point suffices. For Yd - connected ones,
Dyson
06/12/2025
Failure Analysis and Design Optimization of Conventional Grounding Transformers
Failure Analysis and Design Optimization of Conventional Grounding Transformers
I. Core Cause of Damage: Electrodynamic Impact (Complying with GB/T 1094.5 / IEC 60076-5)The direct cause of high-voltage winding end collapse is the instantaneous electrodynamic impact induced by short-circuit current. When a single-phase grounding fault occurs in the system (such as lightning overvoltage, insulation breakdown, etc.), the grounding transformer, as the fault current path, withstands high-amplitude and steep-rise-rate short-circuit currents. According to Ampère's force law
Felix Spark
06/12/2025
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
1 Theoretical AnalysisIn distribution networks, grounding transformers serve two key roles: powering low - voltage loads and connecting arc - suppression coils at neutrals for grounding protection. Grounding faults, the most common distribution network fault, heavily impact transformers’ operating characteristics, causing sharp changes in electromagnetic parameters and status.To study transformers’ dynamic behaviors under single - phase grounding faults, build this model: Assume a tr
Felix Spark
06/12/2025
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
1 Classification of Neutral Grounding Methods for Solar Photovoltaic Power StationsInfluenced by differences in voltage levels and grid structures across regions, the neutral grounding methods of power systems are mainly categorized into non-effective grounding and effective grounding. Non-effective grounding includes neutral grounding via arc suppression coils and neutral ungrounded systems, while effective grounding comprises neutral solid grounding and neutral grounding via resistors. The sel
Dyson
06/12/2025
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
In a neutral-insulated three-phase power system, an earthing transformer provides an artificial neutral point, which can be solidly earthed or earthed via reactors/arc suppression coils. The ZNyn11 connection is typical, where zero-sequence magnetomotive forces in the inner/outer half-windings of the same core column cancel out, balancing fault currents in series windings and minimizing zero-sequence leakage flux/impedance.Zero-sequence impedance is critical: it determines fault current magnitud
Dyson
06/12/2025
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
The neutral grounding mode refers to the connection between the power system neutral point and ground. In China's 35 kV and below systems, common methods include ungrounded neutral, arc-suppression coil grounding, and small-resistance grounding. The ungrounded mode is widely used as it allows short-term operation during single-phase grounding faults, while small-resistance grounding has become mainstream for its fast fault removal and overvoltage limitation. Many substations install grounding tr
Felix Spark
06/12/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放