• 252kV outdoor self-energy power high voltage SF6 circuit breaker
252kV outdoor self-energy power high voltage SF6 circuit breaker
discuss personally
Model
LW58-252(W)/T5000-63
LW58-252(W)/T4000-50
Basic info
Brand ROCKWILL
Model NO. 252kV outdoor self-energy power high voltage SF6 circuit breaker
Rated voltage 252kV
Rated normal current 5000A
Rated frequency 50/60Hz
Rated short circuit breaking current 63kA
Series LW58-252
Product Detail

Product introduction:

The LW58-252(W) outdoor self-energy high-voltage SF₆ circuit breaker is designed for 252kV, 50Hz AC power systems, serving as a critical control and protection device for power grid interconnections. Utilizing SF₆ gas for arc quenching and insulation, it features a self-energy power arc extinguishing double-action interrupter structure paired with a new-type spring operating mechanism. Renowned for its robust switching capability, low operating power, low noise, and high reliability, its technical indicators align with advanced domestic and international counterparts.

This three-phase SF₆ circuit breaker upgrades from single-pole, single-mechanism operation to a three-phase mechanical linkage system driven by a single mechanism. This design reduces mechanical complexity, enhances three-phase linkage reliability, and eliminates the risk of single-phase misoperation.

Main characteristic:

  • Self-Energy Arc Extinguishing Technology: The double-action structure ensures stable breaking capacity under diverse loads.

  • High Operational Efficiency: Requires minimal operating power, with a mechanical life cycle of up to 10,000 cycles for prolonged reliability.

  • Superior Contact Design: Copper-tungsten arc contacts use integral sintering, withstanding high temperatures, minimal arc erosion, and over 20 full breaking operations.

Reliable Sealing & Insulation:

  • Annual SF₆ gas leakage rate < 0.5% via precision sealing technology.

  • Stringent dehumidification processes ensure SF₆ moisture content far below industry standards.

  • High insulation level with creepage distance > 31mm/kV.

Advanced Materials:

  • Arc extinguishing chamber valve plates use lightweight zinc-base alloy for stable gas dynamics and breaking performance.

  • Imported PTFE-composite nozzles offer excellent ablation resistance and consistent arc quenching.

  • Premium Components: Secondary circuit electrical units and SF₆ density relays are high-quality impact-resistant or joint-venture products.

  • Pure Spring Operating Mechanism: Forged from high-strength alloy steel, key components resist wear, ensuring low failure rates during frequent operations.

Main technical parameters:

1732504456227.png

Instructions on placing orders  : 

  • Model and format of the circuit breaker;

  • Rated electrical parameters (voltage, current, breaking current, etc);

  • Working conditions for using (environment temperature, altitude, and environment pollution level);

  • Rated control circuit electrical parameters (Rated voltage of energy-store moter and Rated voltage of opening, closing coil);

  • Names and quantities of spare items needed, parts and special equipment and tools (to be otherwise ordered);

  • The wire connecting direction of the primary upper terminal.

What are the main types of tank circuit breakers?

SF6 Gas-Insulated Circuit Breaker:

  • SF6 Gas-Insulated Circuit Breaker: Uses sulfur hexafluoride (SF6) gas as the insulating and arc-quenching medium. SF6 gas has excellent insulating properties and arc-quenching capabilities, allowing it to meet the high voltage and high current breaking and insulation requirements in a small space. It is widely used in high-voltage and ultra-high-voltage power systems.

Oil-Immersed Circuit Breaker:

  • Oil-Immersed Circuit Breaker: Uses insulating oil as the insulating and arc-quenching medium. Insulating oil has good insulating properties and heat dissipation capabilities, effectively extinguishing arcs and cooling the contacts. However, due to the fire risk and environmental pollution associated with insulating oil, its application range has gradually decreased. Currently, it is mainly used in specific situations where fire prevention requirements are not stringent.


Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
The design of the three-purpose grounding transformer
The design of the three-purpose grounding transformer
Underground Power Cable Transmission LinesDirect - buried power cable lines have large ground - distributed capacitance, causing high single - phase - to - ground short - circuit capacitive current. For 10 kV lines, if this current exceeds 10 A, arcs hardly self - extinguish, risking arc overvoltage and endangering line equipment. Arc extinction is thus necessary. With a Dyn - connected main transformer, an arc - suppression coil on the secondary neutral point suffices. For Yd - connected ones,
Dyson
06/12/2025
Failure Analysis and Design Optimization of Conventional Grounding Transformers
Failure Analysis and Design Optimization of Conventional Grounding Transformers
I. Core Cause of Damage: Electrodynamic Impact (Complying with GB/T 1094.5 / IEC 60076-5)The direct cause of high-voltage winding end collapse is the instantaneous electrodynamic impact induced by short-circuit current. When a single-phase grounding fault occurs in the system (such as lightning overvoltage, insulation breakdown, etc.), the grounding transformer, as the fault current path, withstands high-amplitude and steep-rise-rate short-circuit currents. According to Ampère's force law
Felix Spark
06/12/2025
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
1 Theoretical AnalysisIn distribution networks, grounding transformers serve two key roles: powering low - voltage loads and connecting arc - suppression coils at neutrals for grounding protection. Grounding faults, the most common distribution network fault, heavily impact transformers’ operating characteristics, causing sharp changes in electromagnetic parameters and status.To study transformers’ dynamic behaviors under single - phase grounding faults, build this model: Assume a tr
Felix Spark
06/12/2025
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
1 Classification of Neutral Grounding Methods for Solar Photovoltaic Power StationsInfluenced by differences in voltage levels and grid structures across regions, the neutral grounding methods of power systems are mainly categorized into non-effective grounding and effective grounding. Non-effective grounding includes neutral grounding via arc suppression coils and neutral ungrounded systems, while effective grounding comprises neutral solid grounding and neutral grounding via resistors. The sel
Dyson
06/12/2025
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
In a neutral-insulated three-phase power system, an earthing transformer provides an artificial neutral point, which can be solidly earthed or earthed via reactors/arc suppression coils. The ZNyn11 connection is typical, where zero-sequence magnetomotive forces in the inner/outer half-windings of the same core column cancel out, balancing fault currents in series windings and minimizing zero-sequence leakage flux/impedance.Zero-sequence impedance is critical: it determines fault current magnitud
Dyson
06/12/2025
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
The neutral grounding mode refers to the connection between the power system neutral point and ground. In China's 35 kV and below systems, common methods include ungrounded neutral, arc-suppression coil grounding, and small-resistance grounding. The ungrounded mode is widely used as it allows short-term operation during single-phase grounding faults, while small-resistance grounding has become mainstream for its fast fault removal and overvoltage limitation. Many substations install grounding tr
Felix Spark
06/12/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放