• 2.2kWh portable power station boasts VDA battery
  • 2.2kWh portable power station boasts VDA battery
2.2kWh portable power station boasts VDA battery
discuss personally
Model
WN- 2000
Basic info
Brand POWERTECH
Model NO. 2.2kWh portable power station boasts VDA battery
输出功率 1600W
Energy capacity 2203Wh
Series Portable power station
Product Detail

Description:

This 2.2kWh portable power station boasts VDA battery module and dual back up BMS, which brings you the ultimate safety. It covers almost all your household appliance power needs both indoors and outdoors and can support 15 devices simultaneously. 

Feature:

  • 95% Inverter Efficiency.

  • Equipped with 2 Wireless Charging Pads.

  • 95% of DoD(Depth of Discharge).

  • Fully Charged in 1.5 Hours via AC and Solar Panel Charging.

  • Capable to Charge 15 Devices Simultaneously.

Technical parameter

image.png

image.png


What is the role of VDAs in portable power stations?

Portable substations are usually used in scenarios such as emergency power supply and temporary power support. The applications of VDA battery modules in such substations mainly include the following aspects:

  • Emergency Power Supply:In the event of a power grid outage or insufficient power supply, the VDA battery modules can serve as temporary emergency power sources to provide power support for critical equipment.

  • Peak Shaving and Valley Filling:They can be charged during the low-tariff period and discharged during the high-tariff period, helping users save on electricity bills.

  • Standby Power Supply:When the power supply is unstable or there is a need to temporarily increase the power capacity, the VDA battery modules can be used as standby power sources.

  • Renewable Energy Integration:Used in combination with renewable energy power generation systems such as solar and wind energy, they can store the excess electrical energy and smooth the output of renewable energy.

  • Mobile Power Supply:Portable substations can act as mobile power supplies and be used in occasions where temporary power support is needed, such as outdoor activities and construction sites.


Know your supplier
POWERTECH
We are an electrical company that manufactures and sells high and low voltage electrical products.
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$120000000
Professional Experience
7 years
Workplace
580000m²
占位
占位
Related Knowledges
The design of the three-purpose grounding transformer
The design of the three-purpose grounding transformer
Underground Power Cable Transmission LinesDirect - buried power cable lines have large ground - distributed capacitance, causing high single - phase - to - ground short - circuit capacitive current. For 10 kV lines, if this current exceeds 10 A, arcs hardly self - extinguish, risking arc overvoltage and endangering line equipment. Arc extinction is thus necessary. With a Dyn - connected main transformer, an arc - suppression coil on the secondary neutral point suffices. For Yd - connected ones,
Dyson
06/12/2025
Failure Analysis and Design Optimization of Conventional Grounding Transformers
Failure Analysis and Design Optimization of Conventional Grounding Transformers
I. Core Cause of Damage: Electrodynamic Impact (Complying with GB/T 1094.5 / IEC 60076-5)The direct cause of high-voltage winding end collapse is the instantaneous electrodynamic impact induced by short-circuit current. When a single-phase grounding fault occurs in the system (such as lightning overvoltage, insulation breakdown, etc.), the grounding transformer, as the fault current path, withstands high-amplitude and steep-rise-rate short-circuit currents. According to Ampère's force law
Felix Spark
06/12/2025
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
1 Theoretical AnalysisIn distribution networks, grounding transformers serve two key roles: powering low - voltage loads and connecting arc - suppression coils at neutrals for grounding protection. Grounding faults, the most common distribution network fault, heavily impact transformers’ operating characteristics, causing sharp changes in electromagnetic parameters and status.To study transformers’ dynamic behaviors under single - phase grounding faults, build this model: Assume a tr
Felix Spark
06/12/2025
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
1 Classification of Neutral Grounding Methods for Solar Photovoltaic Power StationsInfluenced by differences in voltage levels and grid structures across regions, the neutral grounding methods of power systems are mainly categorized into non-effective grounding and effective grounding. Non-effective grounding includes neutral grounding via arc suppression coils and neutral ungrounded systems, while effective grounding comprises neutral solid grounding and neutral grounding via resistors. The sel
Dyson
06/12/2025
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
In a neutral-insulated three-phase power system, an earthing transformer provides an artificial neutral point, which can be solidly earthed or earthed via reactors/arc suppression coils. The ZNyn11 connection is typical, where zero-sequence magnetomotive forces in the inner/outer half-windings of the same core column cancel out, balancing fault currents in series windings and minimizing zero-sequence leakage flux/impedance.Zero-sequence impedance is critical: it determines fault current magnitud
Dyson
06/12/2025
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
The neutral grounding mode refers to the connection between the power system neutral point and ground. In China's 35 kV and below systems, common methods include ungrounded neutral, arc-suppression coil grounding, and small-resistance grounding. The ungrounded mode is widely used as it allows short-term operation during single-phase grounding faults, while small-resistance grounding has become mainstream for its fast fault removal and overvoltage limitation. Many substations install grounding tr
Felix Spark
06/12/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放