• 180kW DC/DC EV charger
  • 180kW DC/DC EV charger
180kW DC/DC EV charger
discuss personally
Model
WZ-180kW-1E
Basic info
Brand RW Energy
Model NO. 180kW DC/DC EV charger
Rated Output Rating 180KW
Output Voltage DC150-750V
Connector Options CCS2
Cable Length 5m
Input Voltage DC260-900V
Series DC EV Chargers
Product Detail

Parameters:

Name

DC/DC180kW-CCS1

Size(mm)

750mm X 600mm X 1290mm

Weight(KG)

250KGs

Screen Material

7’LCD

Shell Material

Sheet Metal

DC Input

Voltage

260VDC-900VDC

Current

≤200A

DC Output

Voltage

150VDC~750VDC

Voltage stabilization accuracy

<±0.5%

Current stabilization accuracy

≤±1%(Output load 20%~100% Rated range)

Voltage ripple factor

≤1%(150~750V, 0~20MHz)

Efficiency

≥ 95%, @750V, 50%~100% load current, rated 710V input

IP Degree of protection

IP54

Operating ambient temperature

-40℃~70℃, Above 50℃, use with derating

Relative humidity

≤95%RH, no condensation

Altitude

≤2000 meters,Derating for use above 2000 meters

Cooling mode

Forced air cooling

Remote monitoring mode

Ethernet / 4G/Wi-Fi

Startup mode

RFID/APP

Standby power

180W

Charging standard

IEC-62196-2;EN61851;ISO 15118

Installation method

Floor mounted

Metering accuracy

0.5

Safety protection function

Input Overvoltage Protection

≥900VDC

Input undervoltage protection

≤260VDC

Output overvoltage protection

DC150V ~ 750V can be set

Over temperature protection

Derating above 55 ℃; 75 ℃ protection shutdown

Short circuit protection

Yes

Emergency stop protection

Yes

Lightning protection

Level 2 lightning protection standard

How does a DC EV charging pile convert electricity?

The DC Fast Charger is a device specifically designed for rapidly charging electric vehicles. The DC charging pile initially obtains alternating current (AC) from the power grid, typically at a voltage of single-phase 230V or three-phase 400V, depending on the regional standards. Inside the charging pile, there are power electronic devices that are responsible for converting the AC from the grid into direct current (DC) suitable for use by the electric vehicle's battery.



Know your supplier
RW Energy
Zhejiang Rockwell Energy Technology Co., Ltd. is an international enterprise specializing in the research, development and manufacturing of recloser controllers, power quality management, power monitoring systems and other high-end power equipment. In today's critical period of global energy transition and power system upgrading, the company has gathered a group of top talents in the fields of power engineering, automation control, software development, etc., who carry the enthusiasm and persistence for the power business, and are committed to overcoming the complex problems in the power system, and promoting the intelligent development of the power industry with innovative technology. Mission: To make global electricity smarter, more reliable and more efficient with innovative technology. Vision: To be the leader in global power intelligence.
Main Categories
High voltage/New energy/Tester
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$100000000
Professional Experience
12 years
Workplace
30000m²
占位
占位
Related Products
Related Knowledges
The design of the three-purpose grounding transformer
The design of the three-purpose grounding transformer
Underground Power Cable Transmission LinesDirect - buried power cable lines have large ground - distributed capacitance, causing high single - phase - to - ground short - circuit capacitive current. For 10 kV lines, if this current exceeds 10 A, arcs hardly self - extinguish, risking arc overvoltage and endangering line equipment. Arc extinction is thus necessary. With a Dyn - connected main transformer, an arc - suppression coil on the secondary neutral point suffices. For Yd - connected ones,
Dyson
06/12/2025
Failure Analysis and Design Optimization of Conventional Grounding Transformers
Failure Analysis and Design Optimization of Conventional Grounding Transformers
I. Core Cause of Damage: Electrodynamic Impact (Complying with GB/T 1094.5 / IEC 60076-5)The direct cause of high-voltage winding end collapse is the instantaneous electrodynamic impact induced by short-circuit current. When a single-phase grounding fault occurs in the system (such as lightning overvoltage, insulation breakdown, etc.), the grounding transformer, as the fault current path, withstands high-amplitude and steep-rise-rate short-circuit currents. According to Ampère's force law
Felix Spark
06/12/2025
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
1 Theoretical AnalysisIn distribution networks, grounding transformers serve two key roles: powering low - voltage loads and connecting arc - suppression coils at neutrals for grounding protection. Grounding faults, the most common distribution network fault, heavily impact transformers’ operating characteristics, causing sharp changes in electromagnetic parameters and status.To study transformers’ dynamic behaviors under single - phase grounding faults, build this model: Assume a tr
Felix Spark
06/12/2025
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
1 Classification of Neutral Grounding Methods for Solar Photovoltaic Power StationsInfluenced by differences in voltage levels and grid structures across regions, the neutral grounding methods of power systems are mainly categorized into non-effective grounding and effective grounding. Non-effective grounding includes neutral grounding via arc suppression coils and neutral ungrounded systems, while effective grounding comprises neutral solid grounding and neutral grounding via resistors. The sel
Dyson
06/12/2025
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
In a neutral-insulated three-phase power system, an earthing transformer provides an artificial neutral point, which can be solidly earthed or earthed via reactors/arc suppression coils. The ZNyn11 connection is typical, where zero-sequence magnetomotive forces in the inner/outer half-windings of the same core column cancel out, balancing fault currents in series windings and minimizing zero-sequence leakage flux/impedance.Zero-sequence impedance is critical: it determines fault current magnitud
Dyson
06/12/2025
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
The neutral grounding mode refers to the connection between the power system neutral point and ground. In China's 35 kV and below systems, common methods include ungrounded neutral, arc-suppression coil grounding, and small-resistance grounding. The ungrounded mode is widely used as it allows short-term operation during single-phase grounding faults, while small-resistance grounding has become mainstream for its fast fault removal and overvoltage limitation. Many substations install grounding tr
Felix Spark
06/12/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放