• 150 kVA Single Phase Pole Mounted Transformer
150 kVA Single Phase Pole Mounted Transformer
discuss personally
Model
DR11-150/10
Basic info
Brand Vziman
Model NO. 150 kva Single Phase Pole Mounted Transformer
Rated capacity 150KVA
Series Single Phase Pole Mounted Transformer
Product Detail

Product overview: 

  • WONE is a professional manufacturer of distribution transformers with 10 years of manufacturing experience. 

  • The single-phase Pole-Mounted transformers designed and produced are usually used for urban and rural power distribution .

  • Input voltages:11kv, 12.4kv, 13.2kv, 13.8kv and 34.5kv; Output voltage:240 / 480v, 120 / 240V, etc. 

  • Executive Standards: IEEE C57, ANSI C57, IEC60076 

Leading technology:

  •  Unique winding technology to improve lightning resistance.

  • Small magnetic leakage, high mechanical strength, strong short circuit resistance.

  • Iron core 45° full oblique joint step laminated structure.

The shell:

  • Mitsubishi laser cutting machine and CNC punching, reducing, folding and other equipment to ensure the accuracy of processing.

  • ABB robot automatic welding, laser detection, to avoid leakage, qualified rate of 99.99998%.

  • Electrostatic spray treatment, 50 years of paint (coating corrosion resistance within 100h, hardness ≥0.4.

  • Cylindrical fully sealed construction with self-sealing manual pressure relief valve (according to ANSI specification.

  • Standard NEMA hanger bracket (each device includes pole support bracket plate.

  • Fully sealed structure, maintenance-free, normal operation life of more than 30 years.

The iron core:

  • The core material is high quality cold rolled grain oriented silicon steel sheet with mineral oxide insulation (from Baowu Steel Group, China).

  •  Minimize loss level, no-load current and noise by controlling the cutting and stacking process of silicon steel sheet.

winding:

  • Low voltage windings are made of high quality cable paper wrapped wire.

  • High voltage windings are made of high quality polyurethane enamelled round copper wire.

  • Interlayer insulation using dot adhesive paper, so that the coil bonding into a fixed unit, with excellent insulation resistance.

  • Transformer structure is reliable during normal operation and transportation.

High quality material:

  • Baowu Steel Group production of silicon steel sheet.

  • High quality anaerobic copper from China.

  • CNPC (Kunlun Petroleum) High quality transformer oil (25#).

other:

  •  High strength polymer low pressure casing or high and low pressure porcelain casing.

  •  Equipped with ring type full copper tinned terminal.

  • Install limited current fuses and arresters.

Product parameters:

  •  Input voltage: 11kv, 12.4kv, 13.2kv, 13.8kv and 34.5kv.

  • Output voltage: 0.4kv 0.416 kv 0.420kv 0.440kv 0.480kv.

  • Capacity: 5-167 kva.

  •  Frequency: 50/60 HZ.

  •  Remark: voltage, capacity, frequency, connection group and loss can be customized according to customer requirements.

Ordering instructions:

  •  Main parameters of transformer (voltage, capacity, loss and other main parameters).

  • Transformer use environment (altitude, temperature, humidity, place, etc) .

  • Other customized requirements (tap switch, color, oil pillow, etc) .

  • The minimum order quantity is 1 set, global delivery within 7 days .

  • The normal delivery period is 30 days, with fast delivery worldwide .

What is a single-phase pole-mounted transformer?


The 150 kVA single-phase pole-mounted transformer is a common type of distribution equipment, mainly used to convert high-voltage electrical energy into low-voltage electrical energy suitable for users. This kind of transformer is usually installed on utility poles and is applicable to power distribution in rural, suburban, and some urban areas. The following is a detailed explanation of the 150 kVA single-phase pole-mounted transformer:

Definitions and Characteristics:

  • Single-phase: It means that the transformer has a single independent winding and is applicable to single-phase alternating current systems.

  • Pole-mounted: It means that the transformer is installed on a utility pole and is usually used for outdoor power distribution.

  • 150 kVA: It indicates that the rated capacity of the transformer is 150 kVA, which is suitable for medium-power power distribution.



Know your supplier
Vziman
Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150000000
Professional Experience
3 years
Workplace
10000m²
占位
占位
Related Products
Related Knowledges
The design of the three-purpose grounding transformer
The design of the three-purpose grounding transformer
Underground Power Cable Transmission LinesDirect - buried power cable lines have large ground - distributed capacitance, causing high single - phase - to - ground short - circuit capacitive current. For 10 kV lines, if this current exceeds 10 A, arcs hardly self - extinguish, risking arc overvoltage and endangering line equipment. Arc extinction is thus necessary. With a Dyn - connected main transformer, an arc - suppression coil on the secondary neutral point suffices. For Yd - connected ones,
Dyson
06/12/2025
Failure Analysis and Design Optimization of Conventional Grounding Transformers
Failure Analysis and Design Optimization of Conventional Grounding Transformers
I. Core Cause of Damage: Electrodynamic Impact (Complying with GB/T 1094.5 / IEC 60076-5)The direct cause of high-voltage winding end collapse is the instantaneous electrodynamic impact induced by short-circuit current. When a single-phase grounding fault occurs in the system (such as lightning overvoltage, insulation breakdown, etc.), the grounding transformer, as the fault current path, withstands high-amplitude and steep-rise-rate short-circuit currents. According to Ampère's force law
Felix Spark
06/12/2025
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
1 Theoretical AnalysisIn distribution networks, grounding transformers serve two key roles: powering low - voltage loads and connecting arc - suppression coils at neutrals for grounding protection. Grounding faults, the most common distribution network fault, heavily impact transformers’ operating characteristics, causing sharp changes in electromagnetic parameters and status.To study transformers’ dynamic behaviors under single - phase grounding faults, build this model: Assume a tr
Felix Spark
06/12/2025
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
1 Classification of Neutral Grounding Methods for Solar Photovoltaic Power StationsInfluenced by differences in voltage levels and grid structures across regions, the neutral grounding methods of power systems are mainly categorized into non-effective grounding and effective grounding. Non-effective grounding includes neutral grounding via arc suppression coils and neutral ungrounded systems, while effective grounding comprises neutral solid grounding and neutral grounding via resistors. The sel
Dyson
06/12/2025
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
In a neutral-insulated three-phase power system, an earthing transformer provides an artificial neutral point, which can be solidly earthed or earthed via reactors/arc suppression coils. The ZNyn11 connection is typical, where zero-sequence magnetomotive forces in the inner/outer half-windings of the same core column cancel out, balancing fault currents in series windings and minimizing zero-sequence leakage flux/impedance.Zero-sequence impedance is critical: it determines fault current magnitud
Dyson
06/12/2025
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
The neutral grounding mode refers to the connection between the power system neutral point and ground. In China's 35 kV and below systems, common methods include ungrounded neutral, arc-suppression coil grounding, and small-resistance grounding. The ungrounded mode is widely used as it allows short-term operation during single-phase grounding faults, while small-resistance grounding has become mainstream for its fast fault removal and overvoltage limitation. Many substations install grounding tr
Felix Spark
06/12/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放