• 12kV 17.5kV 24kV outdoor Gas Insulated Ring Main Unit
12kV 17.5kV 24kV outdoor Gas Insulated Ring Main Unit
discuss personally
Model
OMR-24
OMR-12/17.5
Basic info
Brand ROCKWILL
Model NO. 12kV 17.5kV 24kV outdoor Gas Insulated Ring Main Unit
Rated voltage 24kV
Rated normal current 630A
Rated frequency 50/60Hz
1min Power frequency withstand voltage 55kV
Series OMR
Product Detail

Description :

OMR is a ring main unit for the secondary distribution network. RMU(OMR) can be supplied as a 3 or 4-way  standard configurations with additional equipment according to customer specification. OMR can be supplied in 10  different configurations (Such as CVC, CCV, CVV, CFF, CCC, VVV, CCVV etc) suitable for most switching  applications in 12/24 kV distribution networks.  

It is extendable and combined with our own developed technology concept, which is flexible, modular compact  switchgear, they represent a complete solution for 12/24 kV secondary distribution networks. OMR have identical user interfaces. 

OMR is a completely sealed system with a stainless steel tank containing all live parts and switching functions.  A sealed steel tank with constant atmospheric conditions ensures a high level of reliability as well as personnel  safety and a virtually maintenance-free system. 

The OMR concept offers a choice of either switch-fuse combination or circuit-breaker with relay for protection of  the transformer. OMR can be supplied with an integrated remote control and monitoring unit. This product is in conformity with the standards: IEC62271-200, IEC60420

Technical feature :

  • Good insulation performance, compact structural design;

  • High protection level, fully sealed and fully insulated structure;

  • Fast operation performance, high degree of intelligence;

  • Good environmental protection performance, and convenient installation.

Main technical parameters:

image.png

Single Line Diagram:

企业微信截图_17427952361385.png

Structure Diagram:

image.png

image.png


Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Documents
Public.
OMR Type Outdoor Gas Insulated Ring Main Unit
Manual English
Consulting
Related Products
Related Knowledges
What are the common failures in single-phase distribution transformers?
What are the common failures in single-phase distribution transformers?
Single - phase distribution transformers, as crucial voltage transformation and power distribution equipment in the power system, are widely used in rural power grids, low - voltage residential areas, and areas with concentrated single - phase loads.With the continuous increase in the proportion of single - phase loads in the distribution network, the failure rate of single - phase transformers has also increased. Timely identification and handling of these faults are of great significance for e
Felix Spark
06/18/2025
Comprehensive Analysis of Single-Phase Distribution Transformer Technologies in Multiple Application Scenarios
Comprehensive Analysis of Single-Phase Distribution Transformer Technologies in Multiple Application Scenarios
Introduce the 10 kV line to the load center. Following “small capacity, dense points, short radius”, adopt the new single - phase distribution mode, featuring notable low - voltage line loss reduction, high power quality, and reliability. By comparing the economy and reliability of single - phase vs three - phase transformers in different scenarios, this paper analyzes their applicable scope and application suggestions.Single - phase transformers are classified by distribution mode:
Echo
06/18/2025
What are the technical features and applications of single-phase distribution transformers?
What are the technical features and applications of single-phase distribution transformers?
1 Technical Features of Single - phase TransformersFrom the operation practice of foreign distribution networks, it is known that single - phase transformers are quite widely applied. Compared with three - phase transformers, they have unique advantages, which are specifically reflected as follows:1.1 Simple StructureThis characteristic makes that, when using the same materials, for single - phase transformers with the same capacity, their no - load losses are lower than those of three - phase t
Echo
06/17/2025
Application Analysis of High-Voltage Single-Phase Distribution Transformers in Power Distribution Networks
Application Analysis of High-Voltage Single-Phase Distribution Transformers in Power Distribution Networks
1. Safety Hazards in Substation Operation1.1Transformer FailuresTransformers are critical substation equipment and maintenance focal points. Loose/defective components often cause malfunctions, while internal damage (e.g., oil tank impurities/water/bubbles) triggers partial discharge, risking major losses during outages.1.2 Overvoltage RisksOutdoor overvoltage threatens equipment. Lightning-induced impulse currents alter transformer electromagnetic energy, and circuit breaker misoperations cause
Echo
06/17/2025
Prototype Development of 20 kV Single-Phase Distribution Transformer
Prototype Development of 20 kV Single-Phase Distribution Transformer
1. Design of 20 kV Single - phase Distribution Transformer20 kV distribution systems usually adopt cable lines or mixed cable - overhead line networks, and the neutral point is mostly grounded through a small resistance. When a single - phase grounding occurs, there will be no problem that the phase voltage will rise by more than √3 times as in the case of a single - phase fault in a 10 kV system. Therefore, the single - phase distribution transformer of the 20 kV system can adopt the type
Dyson
06/17/2025
Single-Phase Transformer with High Lightning Impulse Withstand Capability
Single-Phase Transformer with High Lightning Impulse Withstand Capability
1 IntroductionTo ensure the safe operation of railways and reduce the risk of lightning damage to railway telecommunication control systems, the author has specially researched and designed a single - phase series transformer with a relatively high impulse voltage withstand level, with the model number D10 - 1.2 - 30/10. This transformer is equipped with an oil conservator and adopts a fully sealed structure (it can also be designed as a dry - type structure according to actual needs). This seri
Dyson
06/17/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!