• 145kV  Dead Tank SF6  Circuit Breaker
145kV Dead Tank SF6 Circuit Breaker
discuss personally
Model
LW-145
Basic info
Brand ROCKWILL
Model NO. 145kV Dead Tank SF6 Circuit Breaker
Rated voltage 145kV
Rated frequency 50/60Hz
Series LW
Product Detail

Description:

The 145kV dead tank SF6 circuit breaker is a high-reliability high-voltage device designed to ensure stable operation of power systems. It adopts a dead tank structure, with live parts sealed in a metal casing filled with SF6 gas, ensuring rapid arc extinction and efficient fault current interruption to safeguard grid safety. The low-center-of-gravity design gives it strong seismic resistance, adapting to harsh environments such as extreme climates. The equipment integrates bushings and current transformers to support multi-functional control such as measurement and protection. With long mechanical/electrical life and a sealed structure, maintenance frequency is significantly reduced. Equipped with anti-misoperation interlocking devices, it ensures the safety of personnel and equipment. Widely used in power, metallurgy, transportation and other fields, it performs excellently in medium and high voltage scenarios.

Product Advantages:

  • The spring operating mechanism of the circuit breaker is safe and stable, maintenance-free, and highly reliable, and meets the requirements of oil-free and gas-free operating mechanism.
  • Self-energy-compressed combined arc extinguisher.
  • The equipment is shipped after the lightning impact test, which eliminates the hidden danger of insulation discharge caused by production and assembly, and ensures the stable and reliable product quality.
  • The quality of the insulators is stable and reliable.
  • High parameterization: The technical parameters of the products are all of the highest standards in the industry.
  • The domestic first-class design team, suppliers and internal control system ensure the safety, stability and reliability of the products, and the products and inspection standards manufactured in the factory have been recognized by the State Grid and the Southern Power Grid Supervision.
  • Using advanced R&D tools such as finite element analysis software, functional analysis, whole-process quality characteristic chain, size chain analysis, potential failure mode and effect analysis (FEMA), etc., the modular design is realized on the basis of ensuring the safety, stability and reliability of product performance.
  • Earthquake resistance of magnitude 9.

Product features:

  • Spring operating mechanism, reliable performance;
  • Excellent breaking performance
  • E2-M2-C2 circuit breaker, electrical life 20 times, mechanical life 10000 times.
  • Strong rated flow capacity;
  • Excellent insulation level, small local discharge;
  • Excellent corrosion resistance;
  • Advanced design tools;
  • Strict process assembly and quality control.

 Use of the environment:

  • Installation location: indoor/outdoor;
  • Ambient air temperature :
  • Maximum temperature: +55°C;
  • Minimum temperature: -40°C; Maximum daily temperature difference: 32 K;
  • Altitude: ≦3000m;
  • Sunshine intensity (noon on sunny day): 1000 W/㎡;
  • Pollution level: III./IV. grade;
  • Icing thickness: 10mm/20mm;
  • Wind speed/wind pressure: 34m/s (equivalent to 700Pa on the surface of the cylinder);
  • Humidity: average daily relative humidity: ≦95%; Monthly average relative humidity: ≦90%;
  • Earthquake resistance: nine degrees;
  • Horizontal acceleration: 0.3g;
  • Vertical acceleration: 0.15g.

Use of the product:

In densely populated areas, in harmony with existing buildings, in important and critical substations, in confined space substation expansions, in flexible retrofits and replacements, in places with heavy loads, for economical and reliable energy management, in power stations, etc.
LW58A-126/145 SF6 canister circuit breaker is one of the new generation of switchgear of Shanghai Siyuan High Voltage Switchgear Co., Ltd., which has won the trust of users with its compact design and reliable performance.
 
Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
The design of the three-purpose grounding transformer
The design of the three-purpose grounding transformer
Underground Power Cable Transmission LinesDirect - buried power cable lines have large ground - distributed capacitance, causing high single - phase - to - ground short - circuit capacitive current. For 10 kV lines, if this current exceeds 10 A, arcs hardly self - extinguish, risking arc overvoltage and endangering line equipment. Arc extinction is thus necessary. With a Dyn - connected main transformer, an arc - suppression coil on the secondary neutral point suffices. For Yd - connected ones,
Dyson
06/12/2025
Failure Analysis and Design Optimization of Conventional Grounding Transformers
Failure Analysis and Design Optimization of Conventional Grounding Transformers
I. Core Cause of Damage: Electrodynamic Impact (Complying with GB/T 1094.5 / IEC 60076-5)The direct cause of high-voltage winding end collapse is the instantaneous electrodynamic impact induced by short-circuit current. When a single-phase grounding fault occurs in the system (such as lightning overvoltage, insulation breakdown, etc.), the grounding transformer, as the fault current path, withstands high-amplitude and steep-rise-rate short-circuit currents. According to Ampère's force law
Felix Spark
06/12/2025
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
1 Theoretical AnalysisIn distribution networks, grounding transformers serve two key roles: powering low - voltage loads and connecting arc - suppression coils at neutrals for grounding protection. Grounding faults, the most common distribution network fault, heavily impact transformers’ operating characteristics, causing sharp changes in electromagnetic parameters and status.To study transformers’ dynamic behaviors under single - phase grounding faults, build this model: Assume a tr
Felix Spark
06/12/2025
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
1 Classification of Neutral Grounding Methods for Solar Photovoltaic Power StationsInfluenced by differences in voltage levels and grid structures across regions, the neutral grounding methods of power systems are mainly categorized into non-effective grounding and effective grounding. Non-effective grounding includes neutral grounding via arc suppression coils and neutral ungrounded systems, while effective grounding comprises neutral solid grounding and neutral grounding via resistors. The sel
Dyson
06/12/2025
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
In a neutral-insulated three-phase power system, an earthing transformer provides an artificial neutral point, which can be solidly earthed or earthed via reactors/arc suppression coils. The ZNyn11 connection is typical, where zero-sequence magnetomotive forces in the inner/outer half-windings of the same core column cancel out, balancing fault currents in series windings and minimizing zero-sequence leakage flux/impedance.Zero-sequence impedance is critical: it determines fault current magnitud
Dyson
06/12/2025
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
The neutral grounding mode refers to the connection between the power system neutral point and ground. In China's 35 kV and below systems, common methods include ungrounded neutral, arc-suppression coil grounding, and small-resistance grounding. The ungrounded mode is widely used as it allows short-term operation during single-phase grounding faults, while small-resistance grounding has become mainstream for its fast fault removal and overvoltage limitation. Many substations install grounding tr
Felix Spark
06/12/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.