• 252kV 363 kV HV SF6 Circuit Breaker
252kV 363 kV HV SF6 Circuit Breaker
discuss personally
Model
LW10B-363/4000-50
LW10B-363/3150-50
LW10B-252/4000-63
LW10B-252KV/3150-50
Basic info
Brand Wone
Model NO. 252KV 363 KV SF6 Circuit Breaker
Rated voltage 363kV
Rated normal current 4000A
Series LW10B
Product Detail

Description:


SF6 circuit-breaker, the circuit-breaker adopts SF6 gas as insulation and arc extinguishing medium, and its arc extinguishing chamber is a single voltage variable opening distance, which is mainly used to meet the rated current and fault current, convert the line, and realize the control and protection of the transmission line. It is equipped with a spring energy storage hydraulic operating mechanism for opening, closing and automatic reclosing. The circuit breaker is divided into two kinds of products: break without closing resistance and break with closing resistance.


Main Features:


  •  The arc extinguishing chamber structure design of the circuit breaker is reasonable, the breaking ability is strong, the contact electric life is long (rated short circuit breaking up to 20 times), and the maintenance interval is long.

  •  The mechanical reliability of the product is good, to ensure the mechanical life of 5,000 times.

  • The circuit breaker operation noise is low.

  • The new hydraulic operating mechanism has no exposed pipeline, reducing the oil leakage link.

Technical parameter:

1719906586792.png

How to deal with the circuit breaker quickly when it fails?

Fault Handling:

  • Establish a fault handling procedure to quickly take action once a fault is detected, minimizing downtime.

  • Record the details of the fault and the handling process for subsequent analysis and improvement.

Emergency Response Plan:

  • Develop an emergency response plan that includes steps for emergency shutdown, fault diagnosis, repair, and recovery, ensuring a swift response in case of unexpected situations.

  • Conduct regular emergency drills to enhance the emergency response capabilities of the operating personnel.



Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
The design of the three-purpose grounding transformer
The design of the three-purpose grounding transformer
Underground Power Cable Transmission LinesDirect - buried power cable lines have large ground - distributed capacitance, causing high single - phase - to - ground short - circuit capacitive current. For 10 kV lines, if this current exceeds 10 A, arcs hardly self - extinguish, risking arc overvoltage and endangering line equipment. Arc extinction is thus necessary. With a Dyn - connected main transformer, an arc - suppression coil on the secondary neutral point suffices. For Yd - connected ones,
Dyson
06/12/2025
Failure Analysis and Design Optimization of Conventional Grounding Transformers
Failure Analysis and Design Optimization of Conventional Grounding Transformers
I. Core Cause of Damage: Electrodynamic Impact (Complying with GB/T 1094.5 / IEC 60076-5)The direct cause of high-voltage winding end collapse is the instantaneous electrodynamic impact induced by short-circuit current. When a single-phase grounding fault occurs in the system (such as lightning overvoltage, insulation breakdown, etc.), the grounding transformer, as the fault current path, withstands high-amplitude and steep-rise-rate short-circuit currents. According to Ampère's force law
Felix Spark
06/12/2025
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
1 Theoretical AnalysisIn distribution networks, grounding transformers serve two key roles: powering low - voltage loads and connecting arc - suppression coils at neutrals for grounding protection. Grounding faults, the most common distribution network fault, heavily impact transformers’ operating characteristics, causing sharp changes in electromagnetic parameters and status.To study transformers’ dynamic behaviors under single - phase grounding faults, build this model: Assume a tr
Felix Spark
06/12/2025
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
1 Classification of Neutral Grounding Methods for Solar Photovoltaic Power StationsInfluenced by differences in voltage levels and grid structures across regions, the neutral grounding methods of power systems are mainly categorized into non-effective grounding and effective grounding. Non-effective grounding includes neutral grounding via arc suppression coils and neutral ungrounded systems, while effective grounding comprises neutral solid grounding and neutral grounding via resistors. The sel
Dyson
06/12/2025
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
In a neutral-insulated three-phase power system, an earthing transformer provides an artificial neutral point, which can be solidly earthed or earthed via reactors/arc suppression coils. The ZNyn11 connection is typical, where zero-sequence magnetomotive forces in the inner/outer half-windings of the same core column cancel out, balancing fault currents in series windings and minimizing zero-sequence leakage flux/impedance.Zero-sequence impedance is critical: it determines fault current magnitud
Dyson
06/12/2025
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
The neutral grounding mode refers to the connection between the power system neutral point and ground. In China's 35 kV and below systems, common methods include ungrounded neutral, arc-suppression coil grounding, and small-resistance grounding. The ungrounded mode is widely used as it allows short-term operation during single-phase grounding faults, while small-resistance grounding has become mainstream for its fast fault removal and overvoltage limitation. Many substations install grounding tr
Felix Spark
06/12/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放